Technical Information
Fixture*:
basin area
top area
Bathing well
42
″
(106.7 cm) x
16-1/4
″
(41.3 cm)
56
″
(142.2 cm) x
23-3/4
″
(60.3 cm)
To overflow
water depth
capacity
13
″
(33 cm)
34 gal (128.7 L)
* Approximate measurements for comparison only.
Model
door maximum
width
door maximum
height
71090115
71090125
58-1/2
″
(148.6 cm)
56-1/2
″
(143.5 cm)
Installation Notes
Install this product according to the installation guide.
To be ADA compliant, install according to the requirements of
the Americans with Disabilities Act (ADA). Use only ADA
compliant components.
Size the drain cutout to fit the drain assembly that will be
used.
Stud positioning is critical.
Studs should be positioned roughly as shown for support clip
or roofing nail installation.
4" (10.2 cm)
6-1/2"
(16.5 cm)
31-1/2"
(80 cm)
54"
(137.2 cm)
73-1/2"
(186.7 cm)
1-1/2"
(3.8 cm)
15" (38.1 cm)
60" (152.4 cm)
19"
(48.3 cm)
60" (152.4 cm) Min
60-1/8" (152.7 cm) Max
3-1/2"
(8.9 cm)
2" (5.1 cm)
D. Drain
8-3/4"
(22.2 cm)
8"
(20.3 cm)
22-1/4"
(56.5 cm)
14-1/4"
(36.2 cm)
8"
(20.3 cm)
31-1/2"
(80 cm)
6" (15.2 cm)
(Typical)
14"
(35.6 cm)
14"
(35.6 cm)
16"
(40.6 cm)
1-1/2" (3.8 cm)
Recommended
Support Clip or
Roofing Nail
Location (5 Total)
30" (76.2 cm)
3"
(7.6 cm)
Drain Cutout
71090125
2-3/4" (7 cm)
Overflow Detail
33-1/2" (85.1 cm)
18" (45.7 cm)
30" (76.2 cm)
Product Diagram
ACCLAIM
TM
ACCLAIM
TM
60
″
(152.4 cm) ADA COMPLIANT BATH/SHOWER SYSTEM
Page 2 of 2
1016222-4-
D