Страница 1: ......
Страница 2: ...ER When you use this meter pay attention to polarity The red testing point must be connected to positive and the black testing point should be connected to negative When the voltage or current value t...
Страница 3: ...Sensitivity 250mV RESISTANCE Ranges x1 0 2 up to 2K medium range 20 x10 2 up to 20K medium range 200 x100 20 up to 200K medium range 2K x1K 200 up to 2M medium range 20K x10 2K up to 20M medium range...
Страница 4: ...4 The voltage will appear on the LCD screen Please refers to next table MEASURING AC VOLTAGE 1 Connect the red testing point to the jack signaled VmA and the black testing point to the jack signaled...
Страница 5: ...AC setting 3 Connect the testing points to the circuit to be measured and read the dB value BATTERY TEST 1 Connect the red testing point to the jack signaled VmA and the black testing point to the jac...
Страница 6: ...over on your multimeter The fuse rarely needs to be replaced and when it does it is usually due to an error in operation If BAT appears on your LCD screen the battery needs to be replaced To replace t...
Страница 7: ......
Страница 8: ...ol se opera con una mano rangos ordenados de manera funcional 5 Aseg rese de que las terminales de medici n y puntas de prueba sean las adecuadas TIPS PARA USAR TU MULTIMETRO Cuando use ste mult metro...
Страница 9: ...50 250 y 1000V Exactitud a escala completa 3 Sensibilidad 10K V CD 25 50V VOLTAJE DE CA Rangos 10 50 250 1000V Exactitud a escala completa 4 Sensibilidad 4K V DECIBELIMETRO 10 a 22dB 0dB 1mW 600 CORR...
Страница 10: ...el rango de V CD 3 Conecte la punta de prueba roja a la polaridad positiva y la negra a la negativa 4 Lea el voltaje CD en la escala y aux liese con la siguiente tabla PRUEBA DE VOLTAJE CA 1 Inserte...
Страница 11: ...a roja dentro del borne VmA 2 Coloque el selector en la posici n de 10 V CA V 3 Conecte las puntas al circuito a probar y lea en la escala roja de dB PRUEBA DE BATERIA 1 Inserte la punta de prueba neg...
Страница 12: ...su mult metro 1 Retire los tornillos de la tapa del mult metro y localice los fusibles 0 5A 250V y 10A 250V respectivamente retire el da ado y reempl celo con uno del mismo valor 2 Tape su mult metro...
Страница 13: ...es to costumer as well as warranty service at any of the addresses mentioned later THIS WARRANTY IS VOID IN THE NEXT CASES If the product has been damaged by an accident acts of God mishandling leaky...
Страница 14: ...EFECTIVA EN LOS SIGUIENTES CASOS 1 Cuando el producto ha sido utilizado en condiciones distintas a las normales 2 Cuando el producto no ha sido operado de acuerdo con el instructivo de uso 3 Cuando e...