Steren CRG-805 Скачать руководство пользователя страница 2

 

Product: Alkaline battery charger

Model: CRG-805

Brand: Steren

WARRANTY

This Steren product is warranted under normal usage against defects in workmanship and materials to the original purchaser for one year from 
the date of purchase.

CONDITIONS

1.- This warranty card with all the required information, invoice or purchase ticket, product box or package, and product, must be presented when 
warranty service is required.
2.- If the product stills on the warranty time, the company will repair it free of charge.
3.- The repairing time will not exceed 30 natural days, from the day the claim was received.
4.- Steren sell parts, components, consumables and accessories to customer, as well as warranty service, at any of the addresses mentioned later.

 

THIS WARRANTY IS VOID IN THE NEXT CASES:

If the product has been damaged by an accident, acts of God, mishandling, leaky batteries, failure to follow enclosed instructions, improper repair by 
unauthorized personnel, improper safe keeping, among others.

a) The consumer can also claim the warranty service in the purchase establishment.
b) If you lose the warranty card, we can reissue it, if you show the invoice or purchase ticket.

RETAILER INFORMATION

Name of the retailer ____________________________________    
Address _____________________________________________
Product ______________________________________________    
Brand _______________________________________________
Serial number _________________________________________     
Date of delivery _______________________________________

In case your product fails or have questions, please contact your nearest dealer. If you are in Mexico, please give a call to our Call Center.  

01 800 500 9000

 

Before using your new Steren´s product, please read this instruction 

manual to prevent any damage.

  C A U T I O N S 

H I G H L I G H T S

H O W   T O   U S E

S P E C I F I C A T I O N S

C H A R G I N G   T I M E

T R O U B L E S H O O T I N G

I M P O R T A N T

 

 

 

 

 

 

 

• 

Do not try to open the device, may cause damages and warranty will be void.

• 

Keep device out of the reach of children.

• 

Do not expose to extreme temperatures.

• 

Do not use or store the equipment near wet places. May cause malfunction or shock 

hazard.

• 

Clean with a soft, dry cloth.

• 

If power cord has been damaged, contact your nearest dealer for a replacement.

• 

When you want to unplug the equipment, pull the plug & release from the AC outlet. 

Never pull from the power cord.

• 

Always disconnect the charger when you are not using it.

• 

Make sure the positive (+) and negative (-) ends of the batteries are inserted in the 

correct directions.

• 

Do not attempt to recharge non-rechargeable type batteries.

• 

Dispose of the batteries in accordance with local and national disposal regulations.

The alkaline battery charger helps to care the environment, it allows you to recharge 

and reuse alkaline batteries, getting the best of those batteries. 

What is more, you can recharge AA / AAA Ni-MH or Ni-Cd batteries. It includes battery 

charge indicator, and foldable cover.

The charge is controlled by IC, that identify the type of battery, then you just need to 

place the battery to recharge and the charger will start to work.

 

• 

Smart charger.

 

• 

Alkaline battery charger.

 

• 

Battery status indicator screen.

Input: 

 

100-240V~ 50-60Hz 100mA 

Output:    

1.2V - - - 1200 mA max.

 

 

(1.2V - - - AAx1 1200mA / AAx2 600 mA / AAx4 300 mA)

 

 

(1.2V - - - AAAx1 600mA / AAAx2 300 mA / AAAx4 150 mA)

 

 

(Alkaline 1.5V - - - AAx4 120 mA)

Nominal consumption: 3.6 kWh/month

Stand-by power consumption: 7 kWh/year

The instructions of this manual are for reference about the product. There may 

be differences due to updates. 

Please check our web site (www.steren.com) to obtain the latest version of the 

instruction manual.

  Product design and specifications are subject to change without notice.

 The alkaline battery charge depends on how many charges had been charged.

Battery 

type

Size

Battery

Charging time

NiMH

AA

1300mAh

1x1hr   /   2x2hrs   /   4x4hrs

2100 mAh

1x2hrs   /   2x4hrs   /   4x7hrs

AAA

600mAh

1x1hr   /   2x2hrs   /   4x4hrs

850mAh

1x1hr   /   2x3hrs   /   4x6hrs

NiCd

AA

700 mAh

1x1hr   /   2x 1hr   /   4x2hrs

AAA

300mAh

1x ½ hr   /   2x1hr   /   4x2hrs

1

. Connect the cable to the charger and to a household outlet.

 

Alkaline batteries can be recharged up to 5 times. With 

each charge the battery capacity will decrease.

2. 

Place the batteries into place, taking care of the polarity. Also 

you can charge only 1 AAA or AA battery. 

The  display  will  light  up  and  it  will  show  an  animated  icon                

indicating that the batteries are charging. When the charging 

is complete, the backlight turns off and the 

battery icon will 

be full

.

This icon indicates a low charge of batteries.

 

To  avoid  damages  in  the  batteries  and  charger,  remember  to  unplug  the             

CRG-805 from the outlet and remove the batteries from the charger once the 

indicator displays that the charge is completed.

This icon is display when the battery doesn’t work correctly or when you 

place the battery into wrong polarity .

Full charge

Low charge

Trouble

Solutions

Batteries don´t charge

Check polarity
If they´re alkaline, check that they haven´t 

been charged more than 5 times.
Check that the charger is connected

properly