10 SPARES 
10.1 Perkins consumable spares  

Owing to the amount of times Perkins amends the parts they fit to each engine we will require the full engine 
build list and serial number. The build list number is generally two letters followed by five numbers with the 
serial number usually beginning with a J, N or a U followed by six numbers and a final letter. E.g.: 
AA12345U123456X. 
Usually the part numbers are on the filters or in the case of air filters on the air cleaner cover. 
We have implemented writing the part numbers to the test sheet should the numbers become illegible in 
which case quote the Stephill Generators serial number.   

 
10.2 

General spares  

Part Number 

Description 

011-0002 

1104D-E44TAG2 ENGINE 

018-0076 

ALTERNATOR ECP34-2S/4 105KVA  SAE3 -11.5 

016-0125 

LIFTING EYE  

016-0539 

REACTIVE SILENCER SSDP120 

016-0540 

ABSORPTION SILENCER  SSDP120 

016-0541 

MANIFOLD PIPE SSDP120 

016-1093 

RAIN CAP 3" 

027-0064 

U CLAMP 67mm 

027-0078 

U CLAMP 80mm 

036-0039 

MCB/COVER 4 MODULE  

036-0074 

EARTH LEAKAGE RELAY ELR-3C 

036-0106 

NM8 250S (FRAME) 200A 3POLE MCCB 

036-0108 

125A 3 POLE MCB 

036-0109 

63A 3 POLE MCB 

036-0110 

32A 3 POLE MCB 

036-0111 

32A 1 POLE MCB 

036-0112 

16A 1 POLE MCB 

038-0114 

HARD WIRE TERMINAL TWIN POST  

038-0115 

HARD WIRE DIVIDER 

038-0116 

HARD WIRE END BRACKET     

043-0017 

RCD BYPASS SWITCH 

044-0002 

SOCKET 230V 16A  

044-0004 

SOCKET 230V 32A  

044-0014 

SOCKET 400V 32A  

044-0026 

SOCKET 400V 63A  

044-0087 

SOCKET 125A 415V 5 PIN  

045-0043 

LED PILOT LAMP 22mm RAD224P RED 230V 

045-0075 

CT 200/5A   

045-0101 

TORDAIL TRANSFORMER CT-1/60 

016-1018 

T/LL140 LEVEL SENSOR 275MM, 10-180, SAE 5 HOLE 

016-1051 

LIQUID LEVEL SENSOR S85/04 P RANGE 

036-0061 

FUSE HOLDER 0-377-00 

036-0066 

FUSE HOLDER 0-376-60 IN LINE 

036-0079 

2AMP FUSE 537-1177 

036-0100 

FUSE 3.15A (541-4690) ANTI SURGE 

036-0101 

FUSE 30AMP 0-377-30  MAXI BLADE 

036-0104 

FUSE 541-3108A  (5amp) 

036-0105 

25AMP FUSE 0-375-25 

036-0113 

FUSE 80amp 0-377-80 Maxi 

036-1050 

BBTECCT35  CONNECTION TERMINAL 35mm 

036-1051 

BBTECEC3P16 END CAP 3 PHASE BUS BAR 

036-1052 

BBTEC3PPIN16 3 PHASE BUSBAR 

038-0107 

TERMINAL BATTERY POSITIVE 1-017-01 

038-0108 

TERMINAL BATTERY NEGATIVE 2-017-01 

038-0307 

12 WAY TERMINAL BLOCK MALE 0-013-06 

038-0308 

12 WAY TERMINAL BLOCK FEMALE 0-013-16 

043-0033 

PROXIMITY SWITCH 613-8202   

045-0018 

E/STOP  

Содержание SSDP120

Страница 1: ...generators co uk Web Web www stephill generators co uk Northants NN8 6AG DO NOT OPERATE THE GENERATOR BEFORE READING THIS MANUAL AND ENGINE MANUFACTURER S OWNER S MANUAL AND WARNINGS THIS STEPHILL GE...

Страница 2: ...s 5 6 6 2 Manual mode 6 6 2 1 Waiting in manual mode 6 6 2 2 Starting sequence 6 6 2 3 Stopping sequence 7 6 3 Automatic mode 7 6 3 1 Waiting in auto mode 7 6 3 2 Starting sequence 7 6 3 3 Stopping se...

Страница 3: ...ng of the acoustic lining It is important to keep the generator clean and well serviced in particular keep all air vents louvers clear of debris to prevent poor performance or possible overheating and...

Страница 4: ...osed of accordingly Warning Although this generator is fitted with a Bunded tank it is the duty of the owner to ensure that it meets with Local National regulations dependant on site location etc 4 4...

Страница 5: ...equipped with an oil pressure and temperature switch and will shut down for low oil pressure and high engine temperature x Inspect the generator visually for signs of fault or damage x Ensure battery...

Страница 6: ...K 1 With c d in position 1 K 10 4 Push button for Test 5 Push button for manual reset 6 Signalling green LED for Aux Supply presence 7 Signalling red LED for relay tripped 8 Terminals for Aux Supply...

Страница 7: ...angeover device to unload the generator The fuel supply de energises and the engine comes to a standstill Should a remote start signal be present while operating in this mode a remote start will not o...

Страница 8: ...u navigation Used for navigating the instrumentation event log and configuration screens For further details please see the more detailed description of these items elsewhere in this manual 6 2 MANUAL...

Страница 9: ...ich the next start attempt is made Should this sequence continue beyond the Set Number Of Attempts the start sequence is terminated and the display shows Fail to Start The starter motor is disengaged...

Страница 10: ...on Suite Software Alternatively to scroll manually through all instruments on the currently selected page press the scroll buttons The autoscroll is disabled To re enable autoscroll press the scroll b...

Страница 11: ...VAh kVArh Generator Phase Sequence Dual Mutual Status 6 5 4 CAN ERROR MESSAGES When connected to a suitable CAN engine the 7310 controller displays alarm status messages from the ECU Press to access t...

Страница 12: ...he instruments press the next page button to select the next instrumentation page 6 6 ECU OVERRIDE When the ECU is powered down when in STOP mode it is not possible to read the diagnostic trouble code...

Страница 13: ...Generator Voltage ph N Generator Voltage ph ph Generator Frequency Generator Current A Generator Load ph N kW Generator Total Load kW Generator Load ph N kVA Generator Total Load kVA Generator Power F...

Страница 14: ...CU WARNING The engine ECU has detected a warning alarm and has informed the DSE module of this situation The exact error is also indicated on the module s display and action taken depending upon the s...

Страница 15: ...fter the pre set number of start attempts EMERGENCY STOP The emergency stop button has been depressed This a failsafe normally closed to battery positive input and will immediately stop the set should...

Страница 16: ...rical trip alarms can be disabled by user configuration In this case Protections Disabled will appear on the module display The alarm text will be displayed but the engine will continue to run This is...

Страница 17: ...Suite Maintenance section x Pressing and holding the stop button when the module s display is on the maintenance alarm section ACCESSING THE MAIN FRONT PANEL CONFIGURATION EDITOR Ensure the engine is...

Страница 18: ...te Start Check that the oil pressure switch or sensor is indicating low oil pressure to the controller Depending upon configuration then set will not start if oil pressure is not low Pre heat inoperat...

Страница 19: ...for loose wires on the DC connector plug socket charge alternator Check continuity of all wires from charge alternator Refer to wiring diagram Check voltage at battery while generator is running volta...

Страница 20: ...250S FRAME 200A 3POLE MCCB 036 0108 125A 3 POLE MCB 036 0109 63A 3 POLE MCB 036 0110 32A 3 POLE MCB 036 0111 32A 1 POLE MCB 036 0112 16A 1 POLE MCB 038 0114 HARD WIRE TERMINAL TWIN POST 038 0115 HARD...

Страница 21: ...14 5 023 1019 CAM 28mm RAD LOCK 1000 28 023 1020 INSERT SLOT 2X4 RAD LOCK 1000 U142 023 1021 HOUSING RAD LOCK 1000 U223 023 1027 DOOR HINGE M8 023 1029 HINGE RADIATOR FLAP 1110 U24 024 1001 HANDLE SLA...

Страница 22: ...into the cylinder is low and consequently the cylinder pressure is lower and so is the temperature The result is the piston is not such a good fit in the bore with increased clearance allowing more oi...

Страница 23: ...spare parts required should be of genuine manufacturer s origin http www meccalte com 12 WARRANTY All equipment supplied by STEPHILL GENERATORS LTD carries a warranty of 12 months from date of despat...

Страница 24: ...4 00 4291 00 00 4 00 00 4291 00 7 00 4 1 29 4 9 4 6 40 1 5 00 4 00 7 00 7 00 00 4 00 4291 00 00 4 00 4 00 00 4291 00 7 00 7 00 4 00 00 00 00 3 6421 5 00 4291 00 00 7 00 4291 00 00 00 00 4291 00 7 00...

Страница 25: ...22 11 1 22 8 931 77 78 8 1 392 67 62 3 1 392 67 1 1 43 6 3 41 3 6 3 92 6 7 6 58 43 60 37 6 7 5 78 92 6 7 7 43 8 779 3 6 3 5 1 8643 7 88 6 22 22 22 88 6 22 22 22 22 22 22 22 22 22 19 8 22 22 22 22 19 8...

Страница 26: ...Control panel door 1 24 16 512 SSDP120 Hard wire door 1 25 16 527 SSDP120 Radiator door 1 26 16 511 SSDP120 Bund blank plate 1 27 16 506 SSDP120 Perkins 1104 radiator plate 1 28 16 530 SSD110 Air outl...

Страница 27: ...8 27 26 25 30 3 40 33 37 38 39 9 18 15 R Golding A 13 10 15 New drawing Date Revision Issue THIRD ANGLE PROJECTION Description Fax Phone Drawing Number Drawn SSDP120 Canopy exploded view 16 548 STEPHI...

Отзывы: