API A065 series Interfacing Via bowling (MC2)/Switch pinsetters
23
PAR_24 (LEFT PIN READ DELAY)
DEFAULT= 130 (2,5 Sec.)
Delay for scan the pins after ball passes trough the start photocell. (1
time unit= 19,2 ms) do not exceed “145” or the pinsetter will not execute correctly the Strike and
Gutter cycle
Note: The
PIN READ DELAY
could be adjusted as need, it’s important scan the pins when they are
standing correctly on deck, before pinsetter table run.
PAR_25 (RIGHT PIN READ DELAY)
DEFAULT= 130 (2,5 Sec.)
Delay for scan the pins after ball passes trough the start photocell. (1
time unit= 19,2 ms) do not exceed “145” or the pinsetter will not execute correctly the Strike and
Gutter cycle
Note: The
PIN READ DELAY
could be adjusted as need, it’s important scan the pins when they are
standing correctly on deck, before pinsetter table run.
PAR_23 (SCIBA INSTALLATION)
Some installation requires 2 Camera (Sciba) for a pair of lanes instead of one. To do this, it’s
necessary create a new PINSETTER set in the Database:Open FOCUS program as authorized user,
then open the CONFIGURATION MANAGER plug-in. Click on the PINSETTER TAB.
Click on
ADD
button to
create a new slot of
Pinsetter parameters then
create a name for this new
pinsetter type
Copy the same parameter from
the original settings (Via Bowling
MC2) to the new column