2.  Turn the thermostat power back on and the   icon will blink for a maximum of 5 

minutes. 

3.  Simultaneously press down both buttons for 13 seconds (note that the backlight 

will blink after 3 seconds and the °C or °F symbol will appear after 8 seconds, but 

continue to keep both buttons pressed down). After 13 seconds, the   icon will 

disappear and the degrees symbol (C or F) will stop blinking, indicating that the 

Security mode is deactivated. Release the buttons.

Long cycle/short cycle mode

The  Long/Short  cycle  activation  is  similar  to  the  Celsius/Fahrenheit  degrees 

adjustment. To switch from long cycle heating (15 minutes, ideal for a heater with 

fan) to a short cycle heating (15 seconds, ideal for a convection heater without 

fan), you must simultaneously press down both buttons during 8 seconds in Day 

mode. After 8 seconds, the C or F icon will blink. Release the buttons. The screen 

then displays CC to indicate short cycle or CL to indicate the long cycle. To switch 

from one mode to the other, press down the bottom button. Once the adjustment 

done, exit this mode by not pressing down any button for 5 seconds.

Minimum ON/OFF time selection in Long cycle

In Long cycle, you can adjust the minimum ON/OFF time (e.g. the minimum time 

between  the  start  and  the  shut  down  of  the  heating).  First,  activate  the  Long/

Short cycle mode as described in the previous section. Press down the bottom 

button for 3 seconds until the time in seconds appears on the screen. Release 

the button. Adjust the minimum time from 90 to 405 seconds, by increments of 

45 seconds (factory setting = 180 seconds). Please note that the Long cycle (CL) 

is automatically activated when we enter in the minimum ON/OFF time selection 

mode. Once the adjustment done, exit this mode by not pressing down any button 

for 5 seconds.

Parameters saving and power failures

The  thermostat  saves  some  parameters  in  a  non-volatile  memory  to  be  able 

to  recover  them  after  being  shut  off  (a  power  failure,  for  example).  These 

parameters are the Day/Night settings, the Single programming mode, the state 

of the Security mode, the maximum symbol of the Security mode, the Celsius/

Fahrenheit symbol, short or long cycle, the number of minutes associated to a 

heating cycle, the number of hours of the night time-switch, the number of hours 

Содержание STE241

Страница 1: ...ther information or to consult this guide online please visit our website at www stelpro com S Y S T M E Q U A L I T C ERTIFI REGISTERED Q U A L I T Y S Y S T E M User s Guide STE241 Low voltage elect...

Страница 2: ...his product to a supply source other than 24 VAC and do not exceed the load limits specified Protect the heating system with the appropriate circuit breaker or fuse You must regularly clean dirt accum...

Страница 3: ...W at 24 VAC 0 5 A Parts supplied one 1 thermostat two 2 mounting screws Selection of thermostat location The thermostat must be mounted on a wall facing the heating unit at around 1 5 m 5 feet above t...

Страница 4: ...r loosen the screw retaining the mounting base and front part of the thermostat Remove the front part of the thermostat from the mounting base by tilting it upward N B The following photos show a conn...

Страница 5: ...Stelpro RE 153T electronic thermostat with a 24 VAC transformer and with the second baseboard connected to a Stelpro RE 153 electronic thermostat without a 24 VAC transformer connection example 1 BLAC...

Страница 6: ...are used Connection diagrams in this guide are only examples 5 Reinstall the front part of the thermostat on the mounting base and tighten the screw at the bottom of the unit 6 Turn on the power 7 Se...

Страница 7: ...the top button to increase the value or the bottom button to decrease it Set points can be adjusted by increments of 0 5 C 1 F To quickly scroll through the set point values press and hold down the b...

Страница 8: ...Day mode 8 hours after being switched to the Night mode For example if you want a night temperature lower than the day temperature both Day Night mode set points will first have to be set at the desi...

Страница 9: ...ay with different set points For example if the Single programming mode is activated and the Night mode timer is set at 8 hours the thermostat will be operating in the Night mode for 8 hours at the ni...

Страница 10: ...ssible to manually change the Day Night mode during a 24 hour cycle However any manual return to the Night mode will re initialize the Night mode timer to the latest value recorded which modifies the...

Страница 11: ...e maintained to ensure frost control Security mode It is possible to impose a maximum temperature set point by activating this mode Then it becomes impossible to exceed this set point regardless of th...

Страница 12: ...the adjustment done exit this mode by not pressing down any button for 5 seconds Minimum ON OFF time selection in Long cycle In Long cycle you can adjust the minimum ON OFF time e g the minimum time b...

Страница 13: ...Single programming mode was previously deactivated In the opposite case the Day mode is automatically reactivated The Security mode is also reactivated if it was previously activated However the icon...

Страница 14: ...y at the electrical panel Check if the heating unit has a switch If so ensure that this switch is turned on The displayed ambient temperature is incorrect Check the presence of an air stream or a heat...

Страница 15: ...rature display resolution 0 5 C 0 5 F Temperature set point range 3 C to 30 C 37 F to 86 F Temperature set point increments 0 5 C 1 F Storage temperature 40 C to 50 C 104 F to 122 F Inputs outputs A 3...

Страница 16: ...rranty If at any time during this period the unit becomes defective it must be returned to its place of purchase with the invoice copy or simply contact our customer service department with an invoice...

Отзывы: