background image

2

INSLAN0314

When cutting or drilling into a wall, be careful not to damage electrical wiring and other hidden utilities.
Because this unit is hot when in use, it may pose risks even in normal operation. Therefore, 

be careful 

and 

responsible

 when using it. 

Never block air vents. This obstruction could lead to overheating, which could result in a fire.
Do not insert or allow foreign objects to enter any air vent as this may cause electric shocks, a fire, or damage to the unit.
This unit has hot and arcing or sparking parts inside. It is not designed to be used or stored in wet areas or areas containing flammable liquids, combustible 

materials or corrosive, abrasive, chemical, explosive and flammable substances such as, but not limited to, gasoline, paint, chlorine, sawdust and cleaning 

products.
Some areas are dustier than others. Thus, it is the user’s responsibility to evaluate if the unit 

must be cleaned 

based on the amount of dirt accumulated on 

and inside air vents. Accumulated dirt can lead to a component malfunction or give a yellowish colour to unit. Failure to install and maintain unit in accordance 

with these instructions poses a fire hasard.
Thermal protection activation indicates that the unit has been subjected to abnormal operating conditions. If the thermal protection remains activated or 

activates and deactivates repeatedly, it is recommended that a qualified electrician or a certified repair centre examine the unit in order to make sure it is not 

damaged. (Refer to the limited warranty)
If the unit is damaged or defective, cut off power supply at circuit breaker and call a certified repair centre. (Refer to the limited warranty)

installation

Suggested mounting height from bottom of dryer

MeN

45” (115 cm)

WoMeN

43” (110 cm)

TeeNAgeRS

41” (105 cm)

SMALL chILDReN

35” (90 cm)

hANDIcAPPeD

37” (95 cm)

MINIMUM heIghT

15” (40 cm)

Recommended fasteneRs

Masonry walls: 1/2” expansion sleeve with 1/4” lag bolt
hollow walls: 1/4” wing type bolts
Wood walls: 1/4” lag screw with washer

WarnInG

tecHnical draWinGs

Note: 

When a part of the product specification must be changed to improve operability or other functions, priority is given to the product specification itself. In such 

instances, the instruction manual may not entirely match all the functions of the actual product. Therefore, the actual product and packaging, as well as the name 

and illustration, may differ from the manual. 

FLOOR OR COUNTER

4"

102mm

11 7/16"

291mm

10"

254mm

4 1/2"

114mm

6 1/4"

160mm

8 1/4"

210mm

8 9/16"

217mm

8 3/8"

213mm

O

1/4"

6mm

TYP.

INSIDE

SIDE

FRONT

MIN 15''

[381mm]

Содержание La Niña

Страница 1: ...t s nameplate This unit must be grounded Switch off the power at the circuit breaker fuse before installing repairing and cleaning the unit Make sure the unit is appropriate for the intended use if ne...

Страница 2: ...ction activation indicates that the unit has been subjected to abnormal operating conditions If the thermal protection remains activated or activates and deactivates repeatedly it is recommended that...

Страница 3: ...d the gypsum see FIG 3 If you have no choice but to fix the 2 other screws in a hollow wall use 1 4 wing type bolts Wall installation in 6 steps 1 Determine the location of the hand dryer and screw th...

Страница 4: ...or energy savings and a moderate noise level three sensitivity detections description and symbol Maximal detection standard 4 Medium detection decreased Minimal detection minimum For operational adjus...

Страница 5: ...dryer Use a small soft brush to gently clean all parts TROUBLESHOOTING PROBLEM DEFECTIVE PART OR PART TO CHECK The hand dryer does not turn on Verify that the dryer is receiving power by checking elec...

Страница 6: ...onic board FIG 4 Remove the two screws and detach the upper tunnel FIG 5 Remove the two screws and serrated bracket that hold the motor FIG 6 Push on the back motor support until it slides out easily...

Страница 7: ...BACK PLATE 3 P SMBP00Z0 MOTOR SUPPORT LOWER Tunnel 4 P SMBP01Z0 UPPER Tunnel 5 ELF 007 HEATING ELEMENT ASSEMBLY with fuselink and protection 120V 1200W 6 M SMBP01Z0 PROTECTIVE GRILL 7 P SMBP03Z0 SERR...

Страница 8: ...for lost profits loss of use of equipment cost of capital cost of substitute products facilities or services shutdowns slowdowns or for other types of economic loss or for claims of a dealer s custom...