INS_D070_1216
INSTALLATION :
1. Thermostat location:
The thermostat must be installed indoor only. It should be mounted on a wall, or on the plenum
and should be connected to CIR-048 appropriate terminals (entrée potentiomètre) as shown in this
wiring diagram below:
2. Wiring diagram:
D070
CIR-048
3. Mounting:
REMOVING THE COVER:
• Using a screwdriver, loose the screw at the bottom of the unit, without removing it
(see
diagram 1
).
• With a screwdriver, gently pull the lock hook upwards, and remove the front cover by tilting it
upwards (see
diagram 2
).
MOUNTING:
• Ensure the mounting surface is levelled.
• Route the wires in the terminal block.
• Insert the two wall anchors into the wall.
• Secure the thermostat to the wall with the two screws provided (see
diagram 3
).
ELECTRICAL CONNECTIONS:
• Make the proper electrical connections according to the circuit diagram.
• Afterward, push all the wires back into the wall.
PUTTING BACK THE COVER:
• Align the rotating knob.
• Put back the cover and ensure the top locks are fastened (see
diagram 4
).
• Gently press the cover and tighten the screw at the bottom of the unit (see
diagram 5
).
4. TEMPERATURE SETTING UP:
Select the temperature by rotating the thermostat knob.
5. Specifications:
Adjustment range:
10°C to 70°C
Operating temperature:
0°C to 45°C
Degree of protection:
IP20
Voltage:
24 VAC
D070
DEPORTED PLENUM THERMOSTAT
Caution:
Turn off the thermostat and all the con-
nected electrical devices (e.g. a heater)
before the installation. The thermostat
must be installed by a qualified person.