background image

  SLP Series Amplifiers

              

Owners Manual  

      

 

 

 

8. Fuse 

The fuse holder is built into the IEC connector, and the power cord must be unplugged from the unit to 
gain access. Replace only with same type 5mm x 20mm, fast acting fuse.  See specifications at the end of 
this manual for proper fuse size. 

 
9. Speaker Output Connections 

This amplifier is designed to accommodate a variety of speaker configurations, depending upon specific 
needs. However, when connecting speaker systems, it is critical that impedance be considered in order to 
ensure reliable operation and prevent permanent damage to the amplifier.  
 

Impedance 

In stereo mode, this amplifier can support speaker loads of 4Ω and higher, on each channel. In 
bridged mono mode, the amplifier will support a single speaker load of 8Ω or higher.  
 
In stereo mode, if more than one pair of speakers are to be connected, each speaker MUST be 
8Ω or higher, otherwise permanent damage will occur. If 4Ω speakers are to be used, ONLY one 
pair may be connected.  
 
In bridged mono mode, only one 8Ω speaker may be connected.  4Ω speakers cannot be 
connected to this amplifier while in bridged mode. If two speakers are to be connected to this 
amplifier while in bridged mode, they MUST be 16Ω or higher. 
 

Binding Posts 

Heavy duty binding posts are intended for bare wire speaker connection. It is important that 
proper polarity be observed when connecting the pair of speakers. When the amplifier is in stereo 
mode, Indi and – connections are provided and clearly marked for connection of a 
speaker pair. When the amplifier is in BRIDGED mode, only connect to the two + (RED) 
connections, as the two – (BLACK) connectors are not used.  
 

Twist Lock Connectors 

These connectors are designed to mate with industry standard Speakon™ connectors. In is 
important to note that separate connections are used for bridged and stereo operation.  
 

 
Specifications 

SLP-200 

SLP-300 

SLP-600 

SLP-900 

RMS Power Output 

 

 

 

 

Stereo 8Ω 

65W x 2 CH 

100W x 2 CH 

200W x 2 CH 

300W x 2 CH 

Stereo 4Ω 

100W x 2 CH 

150W x 2 CH 

300W x 2 CH 

450W x 2 CH 

 Bridged 8Ω 

200W x 1 CH 

300W x 1 CH 

600W x 1 CH 

900W x 1 CH 

 

 

 

 

 

Frequency Response  

10Hz ~ 50KHz ±1.5dB 

Max Input Level  

21dBV / 9.0V  (limiter on) 

S/N Ratio 

>90dB 

>95dB 

>105dB 

>120dB 

Damping Factor 

>200 

>300 

>350 

>400 

Protection 

Short circuit, current limiting, thermal cutoff, 

DC fault, AC mains transients, soft start, AC line fuse 

Cooling 

Variable speed fan 

Power Consumption 

200W 

300W 

500W 

700W 

Fuse Protection 

 

 

 

 

Dimensions 

3.5" (H) x 19" (W)x 15.35" (D) / 2RU 

Weight 

17.6 lbs. 

22.0 lbs. 

26.5 lbs. 

31.0 lbs. 

 
 
 
 
 
 
 
 
 
 