INS_CUST UL REV E
Page 30
K. VERTICAL TERMINATIONS
•
7KH¿UHSODFHPXVWWHUPLQDWHZLWKWKHLQFOXGHGDSSURYHGSRZHUHGWHUPLQDWLRQFDS
•
NO SUBSTITUTION IS ACCEPTABLE.
•
&DUHIXOO\IROORZWKHLQVWUXFWLRQVLQFOXGHGZLWKWKHDSSURYHGSRZHUHGWHUPLQDWLRQFDS
•
DO NOT use an additional speed control on this powervent.
•
You must use the included Capacitor.
8 - VENTING
/+25,=217$/7(50,1$7,219(17&$3/2&$7,21 &/($5$1&(6
VENT
TERMINAL
AIR
SUPPLY INLET
AREA
WHERE
TERMINAL
IS NOT PERMITTED
Figure 8L
7KLVJDVDSSOLDQFHPXVWQRWEHFRQQHFWHGWRDFKLPQH\VHUYLQJDQ\RWKHUDSSOLDQFH
•
DO NOT RECESS TERMINATION KIT INTO OUTSIDE BUILDING MATERIALS - i.e.: brick, stone, siding, etc. If necessary, extend framing so
that termination kit will be exposed once building materials are installed.
•
9HQWWHUPLQDWLRQPXVWQRWEHORFDWHGZKHUHLWZLOOEHFRPHSOXJJHGE\VQRZRURWKHUPDWHULDO7KHÀRZRIFRPEXVWLRQDQGYHQWLODWLRQDLUPXVWQRW
be obstructed.
LOCATION CLEARANCES:
$$ERYHJUDGHYHUDQGDSRUFKGHFNEDOFRQ\LQFKHV>PP@
%2SHUDEOHZLQGRZRUGRRULQFKHV>PP@
&3HUPDQHQWO\FORVHGZLQGRZLQFKHV>PP@UHFRPPHQGHGWRSUHYHQWFRQGHQVDWLRQRQZLQGRZ
'9HQWLODWHGVRႈWLQFKHV>PP@
(8QYHQWLODWHGVRႈWLQFKHV>PP@
)2XWVLGHFRUQHULQFKHV>PP@
*,QVLGHFRUQHUWRQRQFRPEXVWLEOHVLQFKHV>PP@,QVLGHFRUQHUWRFRPEXVWLEOHVLQFKHV>PP@
+0HWHU5HJXODWRU1RWWREHLQVWDOOHGDERYHDJDVPHWHUUHJXODWRUDVVHPEO\ZLWKLQIW>PP@KRUL]RQWDOO\IURPWKHFHQWHUOLQHRIWKHUHJXODWRU
,*DV6HUYLFHUHJXODWRUYHQWRXWOHWIW>PP@
J. Non-mechanical air supply inlet to building or the combustion air inlet to any other appliance.
86´>PP@&$1$'$LQFKHV>PP@
K. Mechanical air supply inlet.
86IW>PP@DERYHLIZLWKLQIW>P@KRUL]RQWDO0DVVDFKXVHWWVLQVWDOODWLRQVIW>P@
&$1$'$IW>P@
/$ERYHSDYHGVLGHZDONRUSDYHGGULYHZD\ORFDWHGRQSXEOLFSURSHUW\IW>P@
08QGHUYHUDQGDSRUFKGHFNRUEDOFRQ\>PXVWEHIXOO\RSHQHGRQDPLQLPXPRIVLGHV@&RPEXVWLEOHLQFKHV>PP@
1RQ&RPEXVWLEOHLQFKHV>PP@
1%HWZHHQWZRKRUL]RQWDOWHUPLQDWLRQVLQFKHV>PP@1RWVKRZQLQ)LJXUH,
2%HWZHHQWZRYHUWLFDOWHUPLQDWLRQVLQFKHV>PP@7HUPLQDWLRQVPD\EHVDPHKHLJKW1RWVKRZQLQ)LJXUH,
127($YHQWFDQQRWEHORFDWHGGLUHFWO\DERYHDVLGHZDONRUSDYHGGULYHZD\WKDWLVORFDWHGEHWZHHQWZRVLQJOHIDPLO\
GZHOOLQJVDQGVHUYHVERWKGZHOOLQJV
3$ERYHIXUQDFHH[KDXVWRULQOHWLQFKHV>PP@1RWVKRZQLQ)LJXUH,
&OHDUDQFHPXVWEHLQDFFRUGDQFHZLWKORFDOLQVWDOODWLRQFRGHV WKHUHTXLUHPHQWVRIWKHJDVVXSSOLHU
N & O: Minimum of
LQFKHV>PP@
required when two exhaust termination caps are placed next to each other. Measurement must be
taken from inside edge of one steel chimney adapter to the inside edge of the other steel chimney adapter. A metal divider plate with same
length and height as termination cap is required to be installed between the caps. Divider plate is not required if caps are at least 24 inches
>PP@DSDUWPHDVXUHGHGJHWRHGJH