35
34
Malfunction
Cause
Remedy
No power at the sensor
n
Fuse faulty, not
switched ON,
break in wiring
n
Short circuit
n
New fuse, turn ON
power switch, check
wiring with voltage tester
n
Check connections
Sensor will not switch ON
n
Twilight setting set to
night-time mode during
daytime operation
n
Bulb faulty
n
Mains power switch
OFF
n
Fuse faulty
n
Detection zone not
properly targeted
n
Adjust setting
n
Change bulb
n
Switch ON
n
Fit new fuse, check
connection if necessary
n
Readjust
Sensor will not switch OFF
n
Continuous movement
in the detection zone
n
Light being operated
is located in detection
zone and keeps switch-
ing ON as a result of
temperature change
n
Light being operated
is in manual override
mode (LED ON)
n
Check zone, adjust or fit
shrouds if necessary
n
Change detection zone
or fit shrouds
n
Deactivate
manual override
Sensor keeps switching
ON/OFF
n
Light being operated is
located in the detec-
tion zone
n
Animals moving in the
detection zone
n
Change zone
or fit shrouds,
increase distance
n
Change detection zone
or fit shrouds
Sensor reach
change
n
Change in ambient
temperatures
n
Use shrouds to define
detection zone precisely
12� Troubleshooting
IS 3180
IS 3360 / IS 3360 MX IS 345
IS 345 MX
Dimensions
(L × W × H)
126 × 65 mm
95 × 95 × 65 mm
124 × 78 mm
94 × 94 × 78 mm
Output
Incandescent / halogen lamp load
Fluorescent lamps, electronic ballast
Fluorescent lamps, uncorrected
Fluorescent lamps, series-corrected
Fluorescent lamps, parallel-corrected
Low-voltage halogen lamps
LED < 2 W
2 W < LED < 8 W
LED > 8 W
Capacitive load
2000 W
1500 W
1000 VA
400 VA
400 VA
2000 VA
100 W
300 W
600 W
176 μF
Mains power
supply
220-240 V, 50 / 60 Hz max. 2.5 mm
2
Angle of
coverage
180° with 90°
angle of perture
360° with 180°
angle of aperture
180° with 45°
angle of perture
180° with 45°
angle of perture
Reaches
Basic
setting 1:
max. 8 - 20 m
tangential;
temperature
stabilised
Basic
setting 2:
max. 4-8 m:
temperature
stabilised
+ precision
adjustment by
repositioning
the lens and
using shrouds
IS 3360
max. 20 m
tangential;
temperature
stabilised
IS 3360 MX
max. 18 m;
temperature
stabilised
+ precision
adjustment
using shrouds
max. 23 × 6 m
(tangential),
max. 12 × 6 m
(radial);
temperature
stabilised
+ precision
adjustment
using shrouds
max. 30 × 4 m
(tangential)
mounted at a
height of 14 m;
temperature
stabilised
+ precision
adjustment
using shrouds
Detection levels
7
11
5
5
Switching zones 448
1416
280
120
Time setting
5 s - 15 min + pulse mode (approx. 2 s)
Twilight setting
2-1000 lux + teach mode
Manual override
(permanent light)
selectable (4 h)
IP rating
Surface-mounted: IP 54 Concealed: IP 20
Temperature
zone
-20°C to +50°C
11� Technical specifications
Surface-mounted installation, round Ø
Surface-mounted installation, square
Concealed installation, round Ø
Concealed installation, square
GB
Содержание IS 3180 COM1
Страница 3: ...4 5 5 s 15 min ...
Страница 4: ...6 7 L L N PE N N N L L N II I L L N PE N N N L L N L L N PE N N N L L N L L N PE N N N L L N a b c d ...
Страница 5: ...8 9 ...
Страница 6: ...10 11 ...
Страница 7: ...12 13 ...