Reach setting/examples
Assuming an installation
height of 2 m, the maximum
reach of the sensor is 12 m.
Optimum adjustment of the
detection zone is possible ac-
cording to needs.
The shrouds provided serve
to cover any desired number
of lens segments and indi-
vidually reduce the reach.
Fine adjustment is also pos-
Reach setting/adjustment
sible by turning the sensor
housing by ± 80° .
The shrouds can be divided
vertically or horizontally along
the grooved divisions, or cut
with scissors . After remo-
ving the decorative ring ,
the shrouds are to be sus-
pended on the upper part of
the sensor lens. The decora-
tive ring is subsequently to be
1
A
B
C
B
A
C
C
reapplied and the shrouds
are fixed firmly in place.
False switching by cars and
pedestrians, etc. is therefore
ruled out, or risk areas delib-
erately monitored.
Function
Switch-off delay
(time setting)
The desired period of oper-
ation of the light can be adjust-
ed continuously from approx.
10 sec. to a max. of 15 min.
When the adjustment screw
is at the left stop position, this
means the shortest time of
approx. 10 sec. When the
adjustment screw is at the
right stop position, this means
the longest time of approx.
15 min.
(Factory setting is at min.).
The shortest time setting is
recommended when adjust-
ing the detection zone and
performing a functional test.
Twilight setting
The desired motion detector
response threshold can be
adjusted continuously from
approx. 2 lux to 2000 lux.
When the adjustment screw
is at the left stop position, this
means daytime operation of
approx. 2000 lux.
When the adjustment screw
is at the right stop position,
this means twilight operation
of approx. 2 lux.
This motion detector is equip-
ped with integrated anti-daz-
zle protection and account
should be taken of the follow-
ing:
If the performance test is
conducted in daylight, the twi-
light setting screw can be set
to night operation.
There must be no motion in
the detection zone within
the set illumination time and
60 seconds thereafter, other-
wise the light will remain illu-
minated.
The same procedure should
be followed for any modifica-
tion of the set twilight thresh-
old.
(Factory setting is
daytime operation.)
The adjustment screw must
be at the left stop position
when setting the detection
zone and for the functional
test in daylight.
appr. 10 sec.-15 min. max.
2 - 2000 lux
After the motion detector has
been connected and fastened
to its wall mount, the system
can be switched on.
Two setting options are
available after removing the
decorative ring.
15
14