STEINEL HiPURformer Скачать руководство пользователя страница 5

GETTING STARTED 

1

2

3

1.

 Plug base station into power source.  Green diode will light up.

2.

 Depress trigger and turn heating cylinder counterclockwise to separate the two

     applicator components. Remove adhesive cartridge from foil pouch and insert into
     heating cylinder.

3.

 Reassemble the applicator by retracting the feed rod and twisting the cylinder until it

     locks into place.

4.

 Insert tool into contact slots on base station to heat adhesive. Status indicator remains

     RED during heat-up (approx. 10-13 minutes).   When the status indicator turns GREEN,
     the adhesive has reached bonding temperature and is ready to use.

5.

 Always wear gloves. Remove tool from base station.

6.

 Unscrew cap (store in handle). Depress trigger to extrude adhesive. Feed rod will

     advance and press against cartridge plunger.

7. 

Apply the adhesive sparingly in either a spot or continuous bead.  Do not spread.

8.

 Join the surfaces to be bonded together, ensure proper alignment of pieces and hold

     firmly in place until the adhesive sets (working times vary).

9.

 Substrates may be machined or planed after 1 hour, however, do not subject the

     bond to stress for 24-48 hours.

4

5

6

If desired, the base station may be mounted on a firm surface.  Use 2.9mm (1/9") 
diameter screws to secure, using the holes provided on the bottom of the unit.

MOUNTING BASE STATION

5

Содержание HiPURformer

Страница 1: ......

Страница 2: ...dicator 6 cartridge cap 7 heating cylinder Voltage 120v AC Output 12 watts in standby phase 200 watts while heating Heat up Time 10 13 minutes Working Temperature 212 284 F Maximum Working Time Approx...

Страница 3: ...Read operating instructions thoroughly before using adhesive applicator WARNING Eye and Skin Irritant Potential Skin and Respiratory Sensitizer Caution Contact with heated product may cause thermal b...

Страница 4: ...dhesive is removable by heating to 280 F with a hot air gun Bond will soften at approximately 280 F but adhesive will not flow or become liquid DO NOT USE HEAT GUNS WITH FLAMMABLE OBJECTS OR SUBSTRATE...

Страница 5: ...sive has reached bonding temperature and is ready to use 5 Always wear gloves Remove tool from base station 6 Unscrew cap store in handle Depress trigger to extrude adhesive Feed rod will advance and...

Страница 6: ...ly cured Optimum bond strength is achieved by joining the two contact surfaces immediately after applying adhesive Hardened excess adhesive can easily be removed with a scraper or putty knife soon aft...

Страница 7: ...nd permanently void this warranty To obtain warranty service call STEINEL s Customer Service Department in the USA at 1 800 852 4343 or in Canada at 1 604 299 3506 A Customer Service Representative wi...

Страница 8: ...to clear cartridge tip Green indicator light appears immediately after changing cartridge Heating cylinder still hot from previous use Ensure that cold cartridge is heated for at least 12 minutes BOND...

Страница 9: ...NOTES 9...

Страница 10: ...FF 662 8 4 04 LB...

Отзывы: