- 10 -
- 11 -
GB
1. About this document
Please read carefully and keep in
a safe place .
–
Under copyright. Reproduction
either in whole or in part only with
our consent.
–
Subject to change in the interest
of technical progress.
Symbols
Hazard warning!
Reference to other informa-
tion in the document .
2 . General safety precautions
!
Disconnect the power
supply before attempting
any work on the unit .
• During installation, the electric
power cable to be connected
must not be live. Therefore,
switch off the power first and use
a voltage tester to make sure the
wiring is off-circuit.
• Installing the sensor involves work
on the mains power supply. This
work must therefore be carried
out correctly in accordance with
applicable national wiring regu-
lations and electrical operating
conditions.
• Only use genuine replacement
parts.
• Repairs may only be made by
specialist workshops.
3. IR Quattro SLIM XS
LiveLink
Proper use
–
Presence detector only suitable-
for mounting on indoor ceilings.
–
For integrating the sensor into the
LiveLink system.
–
A device box with a depth of at
least 57 mm is required.
Package contents
(Fig
.
3 .1)
Product dimensions
(Fig . 3 .2)
Product components
(Fig . 3 .3)
A
Sensor module
B
Decorative trim panel
C
Sensor lens
D
Connecting terminal
4 . Installation
• The sensor is only intended for
concealed, indoor installation in
ceilings.
• Switch OFF power supply
(Fig . 4 .1)
Wiring up the sensor switch:
under section 6 of VDE 0100520, a
multi-core lead containing both the
mains voltage leads as well as the
control leads (e.g. NYM 5 x 1.5 mm²)
may be used for the wiring between
sensor and LiveLink box.
The lead between LiveLink box
and sensor must be no longer than
300 m (for 1.5 mm²). After installing
and switching on the LiveLink box,
the sensor starts to flash once per
second during the initialisation cycle.
...
!
Connecting the mains power supply
lead
(Fig . 4 .1)
Note on parallel connection:
Several sensors can be connected
in a LiveLink system. In this case,
the maximum number of DALI users
must not be exceeded (see Technical
specifications on page 13).
5 . Mounting
• Check all components for
damage.
• Do not use the product if it is
damaged.
• Select an appropriate
mounting location, taking reach
and motion detection into consid-
eration.
(Fig . 5 .1 / 5 .2)
Mounting procedure
• Switch off power supply
(Fig . 4 .1)
• Detach decorative trim panel from
frame.
(Fig . 5 .3)
• Fit mounting box Ø max. 68 mm
into the ceiling cut-out.
(Fig . 5 .4)
• Connect to the mains power
supply.
(Fig . 5 .5)
• Fit sensor module and screw into
place.
(Fig . 5 .6)
• Fit decorative trim panel.
(Fig . 6 .3)
• Switch ON power supply.
(Fig . 6 .3)
• Make settings.
(
➜
"7 . Function")
6. Changing the detection
zone
Detection zone
(Fig . 6 .1 / 6 .2)
The film shroud provided is used
for minimising the detection zone
by a maximum of 40%.
7 . Function and settings
The infrared presence detector
controls lighting, e.g. in offices,
WCs, public buildings or at home, in
relation to ambient light level and the
presence of persons.
The settings are made via the
LiveLink-Box via app.
The sensor is connected to the
LiveLink box as a control unit via
the DALI bus. The sensor uses the
DALI line for communicating with
the LiveLink box and for power. The
LiveLink sensors only work in the
LiveLink system.
LED function
Red LED
Initialisation: LED flashes once every
2 seconds
Normal mode: LED stays OFF.
Setting capabilities via LiveLink
APP:
- Twilight setting
- Time setting
- Semi-automatic /
fully automatic mode
- Constant-lighting control
- Interconnecting several sensors
- Teach mode
- Test mode
- Daytime operation
- IQ mode
- Basic brightness
GB