- 16 -
- 17 -
GB
1. About this document
Please read carefully and keep in a
safe place�
–
Under copyright. Reproduction
either in whole or in part only with
our consent.
–
Subject to change in the interest of
technical progress.
Symbols
Hazard warning!
Reference to other
information in the document�
2� General safety precautions
!
Disconnect the power supply
before attempting any work
on the unit�
• This product must only
be installed by a qualified
electrician in accordance with
national wiring regulations, e.g.
VDE 08 29 (DIN EN 5000 90).
• Fitted improperly, low-voltage
installations can cause extremely
serious personal injury or damage
to property.
• This product must never be con-
nected to a low-voltage (230 V AC)
power supply as it is intended for
connection to an extra-low voltage
power supply.
• Only use genuine replacement
parts.
• Repairs may only be made by
specialist workshops.
3� IR Quattro MICRO KNX
Proper use
–
Sensor switch suitable for indoor
ceiling mounting.
–
Built-in depth at least 65 mm
All function settings can be made via
the optional remote controls RC6,
RC7 or the Smart Remote.
(
➜
"7� Accessories")
Package contents
(Fig� 3�1)
Product dimensions
(Fig� 3�2)
Product components
(Fig� 3�3)
A
Sensor module
B
Micro sensor
C
KNX bus plug connection
4� Installation
Wiring diagram
(Fig� 4�1)
5� Mounting
• Check all components for
damage.
• Do not use the product if it is
damaged.
• Select an appropriate mounting
location, taking the reach and mo-
tion detection into consideration.
(Fig� 5�1 / 5�2)
Mounting procedure
• Switch OFF power supply
(Fig� 4�1)
• In the ceiling, drill a hole of max. Ø
35 mm.
(Fig� 5�3)
• Make plug connection.
(Fig� 5�4)
• Switch ON power supply.
(Fig� 5�4)
• Make settings.
(Fig� 5�5)
(
➜
"
6� Function / Settings")
• Fit sensor into the hole in the
ceiling.
(Fig� 5�6)
...
!
6� Function / Settings
Infrared presence detectors control
lighting as well as HVAC, e.g. in
offices, schools, public buildings or at
home, in relation to ambient light level
and the presence of persons.
The function to be used (activated) is
defined in the "General Settings" pa-
rameter window using the Engineering
Tool Software (ETS), version ETS3.f
and higher.
Note:
The application description is to
be found at
www�knx�steinel�de
1. Issue physical address and gener-
ate application program in the ETS.
2. Load the physical address and ap-
plication program into the presence
detector. When you are prompted,
press programming button
Prog
.
3. The blue LED goes out once pro-
gramming has been successfully
completed.
Functions, RC6
–
Unlocking/locking, service mode
–
Lighting control stay-ON time,
IQ mode
–
HVAC switch-ON delay, room
surveillance, HVAC stay-ON time
–
Basic lighting stay-ON time,
brightness setting, teach-in
–
Presence- and lighting test mode
Functions, RC7
–
Dimming function
–
Light ON/OFF 4 h
–
Saving scene
–
Reset
Smart Remote
–
Control via smartphone or tablet
–
Replaces all remote controls
–
Load appropriate app and connect
via Bluetooth
Detailed descriptions are provided
in the operating instructions for the
particular remote control
LED function
Blue LED
Programming mode: LED ON.
Normal mode: LED stays OFF.
Test mode: LED lights up on detecting
movement.
Remote control: LED flashes 1x per
second
Permanently ON/OFF: LED ON.
7� Accessories (optional)
–
User remote control RC6
EAN 4007841 593018
–
Service remote control RC7
EAN 4007841 592912
–
Smart Remote
EAN 4007841 009151
8� Maintenance / care
The product requires no maintenance.
The detector lens may be cleaned
with a damp cloth if it gets dirty (do
not use cleaning agents).
9� Disposal
Electrical and electronic equipment,
accessories and packaging must be
recycled in an environmentally compat-
ible manner.
Содержание IR Quattro MICRO KNX
Страница 2: ...2 3 DE 10 GB 16 Textteil beachten Follow written instructions 3 3 1 3 2 43 71...
Страница 3: ...4 5 4 3 3 A B C 4 4 1 I O 5 5 5 1 6 m 2 8 m...
Страница 4: ...6 7 6 5 2 6 m 4 m 5 3 35 65 7 5 4...
Страница 5: ...8 9 8 5 5 I O 9 5 6...