When use the magnetic base, please remove the 16# microscope base and screw the microscope 

on the magnetic base, then you can use the magnetic base to attach the microscope on a pipe or 

large equipment. You can change the screw on the magnetic base to make the magnetic base work 

or not. 

 

The instrument adopts DC 3.6V lighting power, LED lamp, compact structure, safe and convenient. 

 

The microscope can work for five days after one time electric charge, there is an indicator light for 

charging, red light indicates charging status, green light means power is sufficient, the charging time 

is about 2 to 3 hours.(the general charging time cannot be more than 8 hours) 

The electrical part of the microscope is safe, reliable and seldom has failure. If the indicating light 

cannot on, the LED illumination also cannot work even after charging. Please remove the 

electrical part from the microscope and send it back to the manufacturer for repairing. Please do 

not t repair by yourself to prevent accidents.

 

6. Maintenance 

(1) After using of eyepiece and the objective lens, please use absorbent cotton or wiping paper 

with a small amount of mixed ether and alcohol (3:1) to gently wipe the surface dust and dirt. 

 

(2) 

To prevent dust effects the microscope imaging quality, please use a plastic bag to cover the 

microscope when it is not in use. 

 

(3) 

Please avoid the microscope to contact with acid, alkaline gas, the microscope also should not 

be placed in damp, cold and hot environment so as not to affect the optical body quality and the 

service life of electrical parts. 

 

(4)

 

The lubricant oil in the microscope is 

special, generally do not have to add, after long-term 

use, the oil may dry and no lubrication. In order to guarantee the quality and precision of the 

instrument, please send to the microscope back to the factory for repairing or contact the 

manufacturer. 

 

 

 

 

 

Содержание NYMCS-605

Страница 1: ...rgical microscope NYMCS 605 NYMCS 606 To ensure the safety obtain optimum performance and to familiarize you fully with the use of this microscope it is recommended strongly that you study this manual...

Страница 2: ...1 STEINDORFF Content 1 Introduction 2 2 Specification 3 3 Parameters 3 4 Structure 4 5 Operation 4 6 Maintenance 5 7 Outfit 6 8 Optional Accessories 6...

Страница 3: ...d for jade porcelain bronze surface tissue structure observation and analysis NYMCS 605 NYMCS 606 uses LED vertical illumination it is portable convenient to use and safety Optional magnetic base is a...

Страница 4: ...th 160mm 3 Focusing distance 25 mm 4 Voltage 3 6V 5 Microscope Dimension H W L 230 110 70 mm 6 Microscope weight 750g Type Magnification N A System WD mm LWD Plan Metallurgical objective PLL10X 0 25 D...

Страница 5: ...put port 15 Illumination connector 16 Microscope Base 5 Operation According to the diagram shows plug the eyepiece 10 into the eyepiece tube 9 screw object lens 1 into the lens holder 2 When install t...

Страница 6: ...n after charging Please remove the electrical part from the microscope and send it back to the manufacturer for repairing Please do not t repair by yourself to prevent accidents 6 Maintenance 1 After...

Страница 7: ...rgical objective 1 3 50X Plan Metallurgical objective 1 4 Illuminator 1 Installed on the microscope 5 Charger 1 6 User Manual 1 8 Optional Accessories 1 5X 20X 40X 60X Plan Metallurgical Objective 2 C...

Отзывы: