24
EN
Item
Operations
Display
Notes
Press
simultaneously,
and keep pressing for 1 second.
SETUP
Press
simultaneously,
and keep pressing for 1
second.
P0000
Press
to increase flashing
digital. Press to move
flashing digital. Input Calibration
Password.
P8416
Password:
8416
Press
to confirm password.
If Calibration Plug is required,
open scale, short cut P2, before
this action.
CLbrt
Full Scale
Press
to enter Full Scale
parameter. Press
to change Full Scale.
Resolution
Press
to go to Resolution
parameter. Press
to change
Resolution.
E 1
Decimal
Point
Press
to go to Decimal
Point parameter. Press
to change Decimal Point.
Pt 0
0: XXXXX
1: XXXX,X
2: XXX,XX
3: XX,XXX
4. CALIBRATION
applicable to scale models SBS-KW-300AW, SBS-KW-300AB and
SBS-KW-300AR
25
EN
Item
Operations
Display
Notes
Gravity
Press
to go to Gravity
parameter. Press
to increase
flashing digital,
press to move flashing
digital, input gravity where scale
is calibrated.
09,794
Zero Calibration
Press
to go to Zero Calib-
ration.
LoAd0
Load1 Calibration
Keep
scale with no load and stable.
Press to confirm weight, and go
to Load1 Calibration.
Press HOLD
UNIT to select weight.
Press
to confirm weight.
If FUL is selected, calibration
ends automatically. If hLF is selec
-
ted,
go to Load2 Calibration.
-----
hLF =
50% F.S.
FUL =
100% F.S.
Load2
Calibration
When Load2 is not neseccesary
please press the button
in order to leave the calibration
maually. In any other case press
the button
to confirm the
weight and finally leave the calib
-
ration.
FUL
-----
End