message will appear on the display
C
. After heating operating mode is activated, the start value of the
set water temperature is 25 °C.
The water in the pool is heated up fastest at maximum throughput of the water through
the heat pump (see "Technical data" section). However, increasing the flow rate reduces
the time spent at the heat exchanger, which means that the difference in temperature
between the water in the pool and the heated water at the pool inlet is lower overall and
therefore less noticeable. Please measure and record the change in the current water
temperature every 30 minutes to determine the actual heating of the pool water.
Activating the heating operating mode
1. Open the protective cover over the display
C
.
2. Put the heat pump into standby mode (see "Display" section).
3. Press the
ON/OFF
button
18
.
4. Repeatedly press the
Mode
button
17
.
The Heating indicator
20
appears. The heat pump is in heating operating mode.
Setting the temperature
1. Repeatedly press the
Down
button
15
or the
Up
button
16
.
After the temperature is set, it can take up to 3 minutes until the heat pump starts up.
The Temperature 1 display
24
shows the desired water temperature in °C.
Activating cooling
The adjustable temperature range in cooling operating mode is 5 – 45 °C. However, the set water
temperature must not differ by more than 15 °C from the ambient temperature; otherwise an error
message will appear on the display
C
. After cooling operating mode is activated, the start value of the
set water temperature is 30 °C.
Activating cooling operating mode
1. Open the protective cover over the display
C
.
2. Put the heat pump into standby mode (see "Display" section).
3. Press the
ON/OFF
button
18
.
4. Repeatedly press the
Mode
button
17
.
The Cooling indicator
19
appears. The heat pump is in cooling operating mode.
Setting the temperature
1. Repeatedly press the
Down
button
15
or the
Up
button
16
.
After the temperature is set, it can take up to 3 minutes until the heat pump starts up.
The Temperature 1 display
24
shows the desired water temperature in °C.
Activating the timer
The adjustable range of the timer is 1 – 24 hours. The delayed operating mode can only be activated in
standby mode and the delayed standby mode can only be activated in operating mode.
Activating the time-delayed operating mode
1. Press the
Clock
button
13
.
The Timer display
22
appears.
2. Repeatedly press the
Down
button
15
or the
Up
button
16
.
The Timer display
22
shows the time until the next desired start of operation of the heat pump in hours.
Activating the time-delayed standby mode
1. Press the
Clock
button
13
.
The Timer display
22
appears.
2. Repeatedly press the
Down
button
15
or the
Up
button
16
.
43
en
Содержание Waterpower 8500
Страница 2: ......
Страница 3: ...1 2 3 4 5 3 de...
Страница 4: ...C B A C 10 6 7 8 9 12 5 11 18 17 16 15 14 13 26 25 24 19 20 21 22 23 4...