background image

Содержание SP-CE358TM

Страница 1: ...Owner s Manual SP CE3 STM FOR SERVICE CALL QQ OO_ E q PARA 5ERVICIO LLAME UIP JLJ LJ _U JJWU...

Страница 2: ...s Basic Air Compressor Components Assembling the Air Compressor Compressor Controls Electrical Power Requirements Breaking In The Pump Operating Instructions Maintenance Storage Servicing Troubleshoot...

Страница 3: ...any signs of damage or corrosion Check all screws bolts nuts and fasteners confirm that they are secure Confirm that all fittings tank petcock hardware and paint are free from rust and corrosion Conf...

Страница 4: ...F INSTRUC TIONS ARE NOT FOLLOWED _ CAUTION CAUTIONS INDICATE A POSSIBILITY OF EQUIPMENT DAMAGE IF INSTRUCTIONS ARE NOT FOLLOWED NOTE NOTES GIVE HELPFUL INFORMATION A WARNING Improper operation or main...

Страница 5: ...ank Drain the condensed water from the tank after each use to reduce rusting If a leak is detected in the tank replace the tank immediately Do not weld drill or modify the air tank of this compressor...

Страница 6: ...he stream can cause injury Tool attachments can be become loose or break and fly apart propelling particles at the operator and others in the work area How to prevent it Always wear ANSI approved Z87...

Страница 7: ...ls or accessories could cause an explosion resulting in serious injury How to prevent it Never operate tools near flammable substances such as gasoline cleaning solvents etc Work in a clean well venti...

Страница 8: ...cut off tools generate dust and abrasive materials which can be harmful to human lungs and respiratory system Some materials such as adhesives and tar contain chemicals whose vapors could cause respir...

Страница 9: ...by accident during maintenance or tool changes Air tools can cause the work piece to move upon contact leading to injury Loss of control of the tool can lead to injury to self or others Poor quality...

Страница 10: ...e inflator nozzles for duster applications Remove air hose to lubricate or add grinding attachments sanding discs drills etc to the tool Never carry the tool by the hose Avoid unintentional starting R...

Страница 11: ...cific tools Maintain the tool with care Keep a cutting tool sharp and clean A properly maintained tool with sharp cutting edges reduces the risk of binding and is easier to control Check for misalignm...

Страница 12: ...ning in contact with hidden electrical wiring could cause electrocution or death How to prevent it Never attach electrical wiring with energized tools Avoid body contact with grounded surfaces such as...

Страница 13: ...come entangled in hair clothing jewelry and other loose objects resulting in injury How to prevent it Never wear loose fitting clothes or apparel that contains loose straps or ties etc which could bec...

Страница 14: ...apable of causing serious injury The pump and manifold generate high temperatures How to prevent it Keep the working part of the tool away from hands and body Do not touch the pump manifold or transfe...

Страница 15: ...lief valve ring daily to ensure proper function and clear possible obstructions To provide proper ventilation for cooling the compressor must be kept at least 12 inches 31cm from the nearest wall in a...

Страница 16: ...s down the motor and relieves air pressure in the pump and transfer tube when the air pressure in the tank reaches the kick out pressure As compressed air is used and the pressure level in the tank dr...

Страница 17: ...ficientairflow andcooling c In cold climates storeportablecompressorsin a heatedbuildingwhen not in use This will reduceproblemswith motorstartingandfreezingof watercondensation d Removethe compressor...

Страница 18: ...nually pull the ring on the valve to relieve air pressure in the tank Pressure Gauge This gauge measures the pressure level of the air stored in the tank It is not adjustable by the operator and does...

Страница 19: ...are on the same circuit the compressor may fail to start Low voltage or an overloaded circuit can result in sluggish starting that causes the motor overload protection system circuit breaker to trip e...

Страница 20: ...12 8 8 14 12 8 8 Grounding Instructions This product is equipped with a cord having a grounding wire an appropriate grounding plug The plug must be plugged into an outlet that is properly installed a...

Страница 21: ...about 15 minutes turn the power switch to the OFF position 6 Close the petcock Turn in the clockwise direction 7 Turn the power switch to the ON position The compressor will start and fill the tank t...

Страница 22: ...ng pressure of the tool never exceed 90 PSI Shut down 1 Turn the power switch to the OFF position 2 Unplug the power cord 3 Reduce pressure in the tank thorough the outlet hose You can also pull the r...

Страница 23: ...RST ADDING OIL TO THE CRANKCASE Serious damage can result from even limited operation unless filled with oil and broken in correctly Follow initial start up procedures closely Damage caused by failure...

Страница 24: ...substantially reduce the performance of your air compressor If you suspect a leak spray a small amount of soapy water with spray bottle If bubbles appear repair or replace the faulty component Do not...

Страница 25: ...t large enough for job Check air requirement of accessory If it is higher than CFM and pressure by compressor you need a larger compressor Most accessories are rated at 25 of actual CFM while running...

Страница 26: ...is being used This is normal in some applications Compressor not large enough If pressure drops too low adjust regulator while accessory is used Check air requirement of accessory it may be higher th...

Страница 27: ...nd reassemble with new seals Motor stalls Low voltage Furnish adequate power Defective pressure switch bleeder valve Replace pressure switch bleeder valve Pressure relief valve opens Tank pressure exc...

Страница 28: ...estarting If bleeder valve does not open replace bleeder valve Wrong wire gauge in extension cord Check for proper gauge and extension cord length Paint spray on internal motor parts Bring to service...

Страница 29: ...ertain level Well ventilated A means of providing fresh air in exchange for dangerous exhaust or vapors ASME American Society of Mechanical Engineers Indicates that the components are manufactured tes...

Страница 30: ...Owner s Manual Exploded View _ Warning Repairs should be made by an aothorized repair center Opening this tool could invalidate your warranty 30...

Страница 31: ...Br_e_ SPT283 31 S_ng _ het 8PT283_32 Head _ SPT283o33 Fa_ SP Cover SPT283_35 V_sher SPT28_ 3_ H_ _ SP Shaft Sea_ SPTg8_8 _arin9 SPT283 g9 Lea_e Ho_ SPT28340 Pressure Ge_ge N_ SPT28341 Comb_natDn _ se...

Страница 32: ...regard to this limited warranty shall be final This warranty gives you specific legal rights and you may also have other rights which vary from state to state RESPONSIBILITY OF ORIGINAL PURCHASER Ini...

Страница 33: ...uired oil adjustments or other installation and start up costs Expendable parts or accessories supplied with the product which are expected to become inoperative or unusable after a reasonable period...