TROUBLESHOOTING: CAUSES AND SOLUTIONS

PROBLEM 

POTENTIAL CAUSE 

POTENTIAL SOLUTION

Desk does not go

 

Re-synchronize Desk 

Refer to Lifting Column synchronization procedure. (see Common

through full range

  

Procedures)

of motion

 

Faulty Lifting Column 

Test Lifting Columns per step 4 of the Troubleshooting Steps,

 

 

and replace any faulty Lifting Columns. Be sure to test all Lifting

 

 

Columns! Why? Because another Lifting Column may have the same

 

 

problem at a different height.

Lifting Columns not

 

Re-synchronize Desk 

Refer to Lifting Column synchronization procedure.

synchronized (one is

 

 

(see Common Procedures)

higher than the other)

 

Faulty Lifting Column 

Test Lifting Columns per step 4 of the Troubleshooting Steps,

 

 

and replace any faulty Lifting Columns. Be sure to test all Lifting

 

 

Columns! Why? Because another Lifting Column may have the same

 

 

problem at a different height.

Desk movement

 

Faulty Lifting Column 

Test Lifting Columns per step 4 of the Troubleshooting Steps,

is not smooth;

 

 

and replace any faulty Lifting Columns. Be sure to test all Lifting

Lifting Columns jerk

 

 

Columns! Why? Because another Lifting Column may have the same

or hop while raised

 

 

problem at a different height.

lowered

 

Lifting Columns are not 

First ensure that glides are properly adjusted, and the Desk is level.

 

parallel with one another, 

 

causing them to bind 

Lift one side of the Desk off the fl oor and reposition so that both

 

 

Lifting Columns are parallel to each other

Error Code displayed

 

Refer to Error Code listing 

Follow instructions on error code listing; is Desk functioning normally

on Digital Controller

 

reset 

anyway? Try initializing the Control Box. 

(see Common Procedures)

PROBLEM ILLUSTRATIONS

Fig. 1

 

- Power Cable not fully seated 

Fig. 2

 - Damaged pins in the 

Fig. 3

 - Frayed/damaged Low-Voltage

in Contol Box 

low-voltage wiring connectors 

Cables (damaged Lifting Column wiring

  harness 

shown)

 

 

Fig. 4

 - Firmware version 1.9 or later

 

 

is compatible with the Digital/Preset

  Controller

WRONG

DAMAGED

CORRECT

CORRECT

CORRECT

DAMAGED

Содержание Ology Bench

Страница 1: ...ox controls all aspects of Desk motion and synchronizes motion of the individual Lifting Columns The Control Box will shut down the entire Desk if a fault is detected For example if one Lifting Column is binding or trapped it will draw significantly more current than the other Lifting Column and the Control Box will shut down the entire Desk to prevent further damage The Controller is the user inte...

Страница 2: ...damage to them Step 4 Test Lifting Columns for proper function and replace any faulty Lifting Columns To do this create a bench testing setup using known good components for example from your troubleshooting parts kit Use these known good components to test the Lifting Columns of the suspect Desk as follows A Verify the function of the bench test setup by connecting all the known good components i...

Страница 3: ...ty C Using the original Power Cable and Controller swap the known good Control Box with the original from the non functioning Desk If it stops working the Control Box is faulty connector Be sure to go through all of the steps above to fully identify all faulty components There could be more than one COMMON PROCEDURES POWER SAVING CONTROL BOX The Control Box automatically powers down into Standby m...

Страница 4: ... positions 1 2 and the Up button simultaneously for 10 seconds 2 Display shows S7 3 Press and hold the Up button until the display reads S0 4 Press S the unit is reset to factory settings SYNCHRONIZING INITIALIZING LIFTING COLUMNS Operate the Desk all the way down to the lowest position and release the Down button Press the Down button again and hold After a few seconds the Desk will visibly move ...

Страница 5: ...seconds of inactivity multi pin connectors Unplug each multi pin connection point and inspect the pins in the Low Voltage Cable Control Box connector connector Are they all straight and making good contact If not try using a push pin to straighten them see Fig 2 on page 6 Otherwise replace necessary components with undamaged versions Damaged Lifting Column Carefully check the condition of the Low ...

Страница 6: ...lumn Test Lifting Columns per step 4 of the Troubleshooting Steps is not smooth and replace any faulty Lifting Columns Be sure to test all Lifting Lifting Columns jerk Columns Why Because another Lifting Column may have the same or hop while raised problem at a different height lowered Lifting Columns are not First ensure that glides are properly adjusted and the Desk is level parallel with one an...

Страница 7: ...d at power off HW initialization FW driver initialization Wait until the HOT error message is no longer displayed May need to wait for entire remaining 18 minutes of 20 minute duty cycle period Try soft reset unplug wait 5 sec plug back in if this does not solve the issue re initialize the Control Box Verify function of Control Box via troubleshooting steps Replace Control Box if faulty Control bo...

Страница 8: ...er com Steelcase youtube com SteelcaseTV 7 2017 2017 Steelcase Inc All rights reserved All specifications subject to change without notice Trademarks used herein are the property of Steelcase Inc or of their respective owners Part No 1076390001 Rev A ...

Отзывы: