background image

Page 3 of 4

939501997 Rev B

®

2

1

Operating sequence for light switch

   

  TOUCH switch - Light is on.

   

  TOUCH switch again - Light is off.

   

  HOLD switch - Light is dimmed to off.

1/4"

SHIPPING SPACER

3

6

NON-RAIL MOUNT

1.

 Position the light onto the worksurface in desired 

location. The shipping spacers will create the desired 
offset (1/4") to the edge of the worksurface.

2.

 Clamp the steel strap to the underside of the 

worksurface to allow for single person assembly.

3.

 Firmly drive the six (6) screws, with a #2 phillips bit, 

attaching the light to the underside of the worksurface 
ensuring fixture is snug. Do not overtighten.

4.

 Remove clamp.

5.

 Remove shipping spacers between vertical 

stanchions and worksurface.

7.

 Connect power supply to light fixture.

GENERAL NOTES:

Verify power supply that is being plugged into light 
fixture is 24VDC.

Light fixture should use 15W Class II or LPS power 
supply (24V; .63A).

6

6.

 Using a 3/32" allen wrench, rotate the adjustment 

screw until the stanchion is perpendicular to the 
worksurface. Use a square to verify perpendicularity. 
Turning the allen wrench clockwise will move the light 
forward, while turning counter clockwise will move the 
light back.

Отзывы: