Free standing installation
The Barbecue must be located away from surrounding
surfaces and combustible materials. Minimum clearance
is 250mm from the sides, 250mm from the rear and 1000mm
overhead.
This appliance must be installed by an authorised person in
accordance with this instruction manual,
AS/NZS 5601.1 – Gas installations (installation and pipe sizing)
and local gas fitting regulations.
Gas inlet is located at the front right hand side 100mm from
the side edge.
LPG: the supplied hose and regulator must be fitted to the
appliance inlet connection. Gas pressure is 2.75 kPa.
The isolating manual shut-off valve connection point must be
accessible when the appliance is installed.
The hose assembly must not be subject to strain, abrasion,
kinking or deformation and must not be in contact
with the floor or any hot or sharp surfaces.
Only use a licensed gasfitter to install this barbecue and other
trades as applicable; builder or bricklayer.
The operation of the appliance must be tested by the installer
to confirm all burner flames are blue in colour, stable and
completely ignite at both high and low flame settings with no
appreciable yellow tipping, carbon deposition, lifting, floating,
lighting back or objectionable odour. Test burners individually
and in combination.
Minimum LPG cylinder is 4.5 kg and the maximum LPG
cylinder is 9.0 kg
The outdoor area in which the barbecue is positioned must
meet the following requirements:
1. there may be walls on all sides, but there must be at least
one permanent doorway and no ceiling;
2. there may be no more than two side walls when there is a
ceiling;
3. there may be partial overhead cover, including a ceiling, but
with no more than two walls and with the following
conditions:
a) At least 25% of the total wall surface is completely
open.
b) At least 30% of the remaining surface is open and not
delimited.
If positioning on a balcony or terrace, at least 20% of the total
wall surface must be open.