![Steca PL2085 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/steca/pl2085/pl2085_users-and-installers-manual_1369111011.webp)
4.2 Sequence of operation
Caution: The charging station must be set to “Charge Stop” at the rotary switch before a battery
is disconnected.
If installation has been correctly carried out and if the module is supplying a high enough voltage then the display works.
The charging station is ready for operation. The empty batteries can now be connected. It is imperative that the correct
polarity is observed.
Open and closed lead storage batteries, and closed gel and flow batteries can be charged, whatever their charge.
Intended sequence of events:
•
Before connecting a battery make sure that this channel shows at the display an empty battery symbol.
•
Connect empty battery to a free channel
•
Check the display for this channel to see that the battery symbol does not show any fault.
•
The charging process starts automatically and is carried out by the charging station fully automatically provided the
rotary switch is not set to “CHARGE STOP“. The battery that was connected first has priority and is charged first
•
If the display shows a full, unchanging battery symbol, this means that this battery has finished charging.
•
Turn the rotary switch to the same number as this full, unchanging battery symbol, and read off the ampere hours
charged.
•
Turn rotary switch to “CHARGE STOP“ and disconnect the battery.
•
Turn the rotary switch away from “Charge Stop“ so that the other channels can be charged further.
The charging station determines the charged ampere-hours from the charged current and the time that has passed.
These are shown on the display. If the charging station is on float charge then the ampere-hours are no longer metered.
Supplying details of the ampere-hours in this way enables the charging station operator to invoice the customer fairly.
The customer only pays for the ampere-hours charged regardless of the state of the battery, e.g. in €/Ah or $/Ah, etc.
Block schematic diagram for parallel connection: