Steca PL2085 Скачать руководство пользователя страница 11

 

4.2  Sequence of operation 

Caution: The charging station must be set to “Charge Stop” at the rotary switch before a battery 
is disconnected. 

 

If installation has been correctly carried out and if the module is supplying a high enough voltage then the display works.  
The charging station is ready for operation.  The empty batteries can now be connected.  It is imperative that the correct 
polarity is observed. 

Open and closed lead storage batteries, and closed gel and flow batteries can be charged, whatever their charge. 

Intended sequence of events: 

 

Before connecting a battery make sure that this channel shows at the display an empty battery symbol. 

 

Connect empty battery to a free channel 

 

Check the display for this channel to see that the battery symbol does not show any fault. 

 

The charging process starts automatically and is carried out by the charging station fully automatically provided the 
rotary switch is not set to “CHARGE STOP“.  The battery that was connected first has priority and is charged first  

 

If the display shows a full, unchanging battery symbol, this means that this battery has finished charging. 

 

Turn the rotary switch to the same number as this full, unchanging battery symbol, and read off the ampere hours 
charged. 

 

Turn rotary switch to “CHARGE STOP“ and disconnect the battery. 

 

Turn the rotary switch away from “Charge Stop“ so that the other channels can be charged further. 

The charging station determines the charged ampere-hours from the charged current and the time that has passed.  
These are shown on the display.  If the charging station is on   float charge then the ampere-hours are no longer metered.  
Supplying details of the ampere-hours in this way enables the charging station operator to invoice the customer fairly.  
The customer only pays for the ampere-hours charged regardless of the state of the battery, e.g. in €/Ah or $/Ah, etc. 

Block schematic diagram for parallel connection: 

 

Channel 2

Channel 1

Battery

+

+

+

 

Operating instructions PL2085 charging station 

Page 11 

10.12.2007 

Содержание PL2085

Страница 1: ...User s and Installer s Manual Charging Station for Photovoltaic Systems PL2085 704 937 07 50 PHOTOVOLTAIK PHOTOVOLTAIC PHOTOVOLTAIQUE FOTOVOLTAICA EN...

Страница 2: ...5 Charging in order of priority 6 2 2 6 Ampere hour meter 6 2 2 7 Rotary switch 6 2 2 8 Display 7 2 2 9 System voltage 7 3 Installation 7 3 1 Precautionary measures 7 3 2 Choice of location for instal...

Страница 3: ...g all work Photovoltaic modules generate electricity when they admit light The voltage is at its full level even with a low incidence of light so exercise care when working and take appropriate safety...

Страница 4: ...ng station The batteries are charged as quickly as possible and also economically in order of priority according to when they were connected and using the latest charging process In addition an MPP Tr...

Страница 5: ...gh energy is available and this battery is next in line as far as priority is concerned the charging station starts charging an intact empty battery once it has been connected with up to 5A first thir...

Страница 6: ...on to about 35mA In this mode the charging station draws its supply from a battery connected to it This is necessary in order that important data such as the priorities and charging phases of the batt...

Страница 7: ...odation National Electric Code with Article 690 3 2 Choice of location for installation Ideally the charging station should be installed in the same well ventilated room as the batteries minimum clear...

Страница 8: ...arking will occur Only use properly insulated tools Never touch bare lead ends Insulate immediately every bare lead end that is not going to be connected straight away Only carry out installation work...

Страница 9: ...the batteries Then the modules must be separated from the control unit In order to avoid sparking this must be carried out at night or with the modules covered 3 4 Safety measures 3 4 1 Flammability...

Страница 10: ...ging station is charging the batteries but that no battery was selected for further information 4 1 2 Description of second line of display The charging and error states of the 8 channels are indicate...

Страница 11: ...ary switch is not set to CHARGE STOP The battery that was connected first has priority and is charged first If the display shows a full unchanging battery symbol this means that this battery has finis...

Страница 12: ...ted against destruction by a variety of measures Nevertheless great care should be taken to ensure that the charging station is operated correctly Some of the malfunctions are signalled by the display...

Страница 13: ...f notification of the fault is provided immediately after it is discovered Legal guarantee claims are to be directed to the seller The seller must be informed before legal guarantee claims are process...

Страница 14: ...704937...

Отзывы: