SteamSpa 10.5KW Скачать руководство пользователя страница 18

SteamSpa

 

PHONE: 800-856-0172 FAX: 866-560-5662 http://steamspa.com [email protected]

Page 18

INST

ALLA

TION & USER GUIDE

CONTROL PANEL OPERATION

The control panel has a digital temperature control system which can start, stop or pause in the 

preset time to keep the temperature at the set number.

ON/OFF

When system is powered, all functions will still not be activated and remain in a waiting state. 

Digital tube will display ---- (

Fig.1

). In the waiting state, press the      button to turn on the system 

and activate steam function. System will recall last use steam time and TEMP, system begins 

to count down. During this time, the digital tube will display the ambient temperature. Steam 

temperature display range is 32° F-140° F.

When the actual temperature is lower or equal to 32° F, the digital tube will display 32° F. When 

the actual temperature is higher or equal to 140° F, the digital tube will display 140° F. The last digit 

displays as the     unit (

Fig.2

) of Fahrenheit temperature. The default steam time is 30 minutes. 

When lacking water, the heating elements  will stop heating and the water inlet valve will work  

automatically. If there is no water detected in 5 seconds or the water coming in does not reach the 

set point in 15 seconds, the digital tube will display        (

Fig.3

)to indicate an error of not enough 

water cycling. If there is enough water cycling, the steam function will return to normal. When 

the steam function is started, if the ambient room temperature is higher than the set point, the 

heating element will stop heating, the digital tube will flash to display the current environment 

temperature; when the environment temperature is lower than the set point, the heating element 

will work again, the digital tube will display current room temperature normally.

When the system is on, press  button to turn off the system, or when the steam time is over 

the system shuts off. 10 minutes after the system is shut off, the drainage function will be started 

automatically for 7 minutes.

TIME AND TEMPERATURE SETTING

When system is on,      press button twice, system will cycle switch in time setting, TEMP setting 

and ambient TEMP display state (

Fig.4

). When the digital tube displays dashes across the 

screen it will allow you to set the duration of the steam bath. During this time, press      or      to 

adjust steam time. Its range is 1-60 minutes, with 1 minute intervals. If there is no adjustment 

in 5 seconds, the system will exit time setting automatically and the LED will display current 

ambient TEMP. When the LED screen shows number and TEMP unit F, it is displaying the indoor 

ambient temperature. When the TEMP unit F flashes on the LED screen, it means the system is 

in the steam TEMP setting state. During this time, press      or      to adjust steam TEMP (

Fig.5

). 

Its range is 50°~130° Fahrenheit, with 1° increments. If no adjustment is done in 5 seconds, 

the system will exit the TEMP setting automatically and the LED screen will display ambient 

temperature.

MEMORY FUNCTION

When system is on, it recalls the last time used with the steam time and TEMP. After adjusting 

steam time and steam TEMP, press      for about 1.5 seconds to adjust time and TEMP 

parameters as current state. The LED screen will show current settings. When system is on, press 

to switch modes between SET1 and SET2. The LED screen displays the current mode.

LIGHT FUNCTION

When the machine is started, press      button to turn on/off light function. When the light is turned 

on, the digital tube will temporarily display        (

Fig.6

). When the light is turned off, the digital tube 

will temporarily display        (

Fig.7

). Screen will turn to display ambient TEMP if no operation is 

selected in 5 seconds.

Fig.1

Fig 2

Fig.3

Fig.4

Fig.5

Fig.6

Fig.7

Содержание 10.5KW

Страница 1: ...GUIDE 4 5KW 6KW 7 5KW 9KW 10 5KW 12KW 15KW MODELS Steam Spa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com W HIS P E R QUI E T B U I L T IN A UTO D R A I N C O N TIN U O U S ST E A M Q UIC K S TAR T ...

Страница 2: ...Steam Spa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com ...

Страница 3: ...RATOR 4 PLUMBINGINSTALLATION 6 STEAM GENERATORSPECIFICATIONS 8 ELECTRICALREQUIREMENTS 9 ASSEMBLYGRAPH FORPOWERWIRE 10 INSTALLATIONOFTHE TOP LIGHT 12 STEAM GENERATORDISSECTIONDIAGRAM 13 CARE USEFORTHE CONTROL PANEL 14 CONTROLLERBOXCONTENT 14 CONTROLPANELINSTALLATIONINSTRUCTIONS 15 TESTINGTHEMACHINE 16 CONTROLPANELDIAGRAM 16 CONTROLPANELOPERATION 17 STEAM GENERATORMAINTENANCE 18 TECHNICALPARAMETERS ...

Страница 4: ...ofdelivery 3 Read installation instructionsindetailforasecureandeffectiveinstallationofSteamSpagenerators 4 SteamSparecommendstheuseofalicensedplumberandelectricianforproperinstallationofSteamSpagenerators 5 SteamSpashallnotberesponsibleforproductdamageormalfunctioncausedbyself installationorinstallation procedures which do not complywithusermanual 6 SteamSpageneratorsareforindooruseonly CHOOSINGT...

Страница 5: ...designofsteam room pleaseconsult withaqualified designer architect or builder Dual Steam Outlet for 10 5kw 12kw 15kw Single Steam Outlet Control Panel AROMA TRAY RESERVOIR Supply Pressure Relief Valve Steam Generator Water Inlet 3 8 stainless steel braided flex hose Water Drain Valve 12 12 SAFETY VALVE WATER INLET PIPE WATER DRAINAGE 3 8 STAINLESS STEEL BRAIDED FLEX HOSE 1 2 CONNECTION WATERLINE S...

Страница 6: ...NTION Theillustrationisjustanexample thepracticalinstallationmustcomplywiththenation selectricalcriteria andbe done byaprofessionalelectrician Control Panel outside room Control Panel inside room Control Panel inside room The steam outlet The spare place under the wash pan possible location The steam generator Light ...

Страница 7: ...pperpipeasthesteampipebetweenthesteamgeneratorandthesteamnozzle 3 Theheat insulationmaterialusedtoinsulatethesteampipeshouldberesistanttotemperaturesashighas250 Forhigher 4 Theshorter thedistance thebetter Trytodecreasethenumberofelbowstopreventcreatingvalleysortraps STEAM HEAD 3 4 ATTENTION Steam Headandthesteamoutletgetveryhot trytoavoidinstallingthesteamheadinapositionwhichwilleasily comeinto c...

Страница 8: ...not connectthesafetyvalveorsteamlinetodrainline SAFETYVALVE 3 4 1 Safetyvalveisanautomaticsystemthatisactuatedbypressureinordertopreventsteampressureincreasingintheinterior ofthegenerator 2 Thepressurelimitrangeofthesafetyvalveis15PSIandthepressurewillbegintodecreaseifpressureshouldcomeoverthis value 3 Ifit isallowed bylocalcodes providethesafetyvalvewithexteriordrainpipe 4 Donot dismantlethepress...

Страница 9: ...age 206mm 188mm 151mm 32mm 43mm 142mm 266mm 302mm 395mm Fuse for wire power supply Power wire hole C ontr olle r w ir e and light wire hole 304mm 400mm 160m m 100m m 30mm 30mm 1 8 0 mm 2 6 0m m 3 7 0 mm Steam outlet S a f e t y valve Water inlet Water drainage Fuse for wire power supply Power wire hole C o n tro ller wire an d lig h t wir e hole Fuse for wire power supply Fuse for wire power suppl...

Страница 10: ...mgenerator 2 Insulated copper wireshouldbeusedwithananti heattemperatureof90Candaspecifiedvoltageof300V Refertonational orlocalelectricityconsumptioncodeforthespecifications Refertotheammeterfortheampere 3 Connect suitablysizedequipment groundingwireintothegroundterminal 4 All theconnectionsmustbeinaccordancewithnationalandlocalelectricityconsumptioncodesandbeinstalledby professional electricians ...

Страница 11: ...otconnectelectriccurrentdirectlytoheatingelements WARNING Thisgraphisforexplanationonly Foractualinstallation refertonationaland localelectricityconsumptioncodesby professional electricians Ampere Meter Ty p e Power KW S600 S750 6 7 5 9 240V 240V 240V 25 32 38 10 8 8 150 225 300 Applicable space of the room cu Ft El e c t r i c i t y supply 1PH E l e c t r i c current A Specifications for power wi...

Страница 12: ...ter valve Drai n water valve Term inal B lock J1 1 J2 1 J3 1 J3 2 J2 2 J1 2 J1 J2 J3 S S G Yellow Green R ed B lack Red Black White Black Yellow R ed B lack Red Red Red Red Su p p ly R ed B lack Red Black L1 L2 Water Level Sensor Red S h o r t P i n Bl ack Lo n g P i n Yel l o w Mi d d l e P i n Red Red Red S750 S900 Red Red Black Black Black Black Black Blac k Red Black J1 1 J1 2 J1 S S L1 G S450...

Страница 13: ... C ontrol P anel Fill water valve Drain water valve Term inal B lock J1 1 J2 1 J2 2 J1 2 J1 J2 S S G Yellow Green R ed B lack Re d Black White Bla c k Yellow R ed B lack Red Red Red Red Su p p ly R ed B lack Black L1 Water Level Sensor Red S h o r t P i n Bl ack Lo n g P i n Yel l o w Mi d d l e P i n S1200 L2 Red Black Red Red Black Black Red S1050 To C ontrol P anel Fill water valve Drain water ...

Страница 14: ...IONDIAGRAM 1 2 3 4 6 5 7 13 14 12 9 11 8 10 15 17 16 1 ENCLOSURE 2 INSULATIONBRACKET 3 CIRCUITBOARD 4 STEAMOUTLET 5 PRESSURERELIEF VALVE 6 WATERFILLVALVE 7 WATERDRAINVALVE 8 SUBSIDIARYWATERTANK 9 MAINWATERTANK 10 HEATINGELEMENT 11 221FHI LIMIT 12 TRANSFORMER 13 TERMINALBLOCK 14 FUSE 15 GROUNDWIRECONNECTOR 16 RELAY 17 WATERLEVELSENSOR ...

Страница 15: ...r inoperativeinstallation SingleControl PanelwithTemperaturesensormustbeinstalledinsidebathingarea5feetabovefloor Donotinstall Control directlyaboveSteam Headorbelowshowerheadbutratherintheseatingareaonaverticalwall Doingsomayresultinimproper temperaturereading and orinoperablecontrol DualControl PanelwithTemperaturesensorinMasterControlmustbeinstalledinsidebathingarea5feetabovefloor Donot install...

Страница 16: ...esteamgeneratorandconnectwith thecorresponding wireinthegenerator Connectingthewireofcontrol paneloutsideroom tothewireofcontrolpanel insidetheroom When connecting wirespleasefollowarrowsonconnectorheadsforproper connection Failureto dosowillresultindamagingofcontrol pins STEPFOUR Startthepower supplyofsteamgenerator checkandadjustconnection checkeach item on thepagetomakesureallfunctionsworkwell ...

Страница 17: ...y Astimegoeson thetemperaturedisplayedinthecontrolpanelwillrise withthe temperaturein theroombeforeitstopsandstaysatthesettemperature 5 Based on differentrequirementsoftheuserfortemperatureandsteamtime thecontrolpanelcanadjusttemperatureand steam time Whiletestingthemachine setthetimetobe30minutesandthetemperaturetobe120F 6 When theset steamtimeisdue thesystemwillshutoffthesteamandlightfunctionaut...

Страница 18: ...illdisplaycurrentroomtemperaturenormally Whenthesystem ison press buttontoturnoffthesystem orwhenthesteamtimeisover thesystem shutsoff 10minutesafterthesystemisshutoff thedrainagefunctionwillbestarted automaticallyfor 7 minutes TIMEANDTEMPERATURE SETTING Whensystem ison pressbuttontwice systemwillcycleswitchintimesetting TEMPsetting andambient TEMP displaystate Fig 4 Whenthedigitaltubedisplaysdash...

Страница 19: ...argedcompletelybeforecuttingoffpowersupply 2 Thereshould not beanyleakageordamageamongthesteamgenerator steamnozzle componentsandpipes Theyshould be checked and repairedannually 3 Clean thewater supplypipesofthesteamgeneratoronceayear 4 Checkallthefaucetconnections toensurewethertheyaretightandnotdamagedduetooverheat 5 Checkthesedimentsaccumulatedinthewatertankandelectricheatingtube Ifthesedimenti...

Страница 20: ...not connectedproperly 2 Trouble with generator motherboard 1 Checkwhethertheconnectionplug betweenthecontrolpanelandthe generatorhasbecome loose and whetherthepowercircuitryhas goodcontact 2 Replacethemotherboard Water leakage 1 Thewaterpipeconnectorbecomes looseorpipeisbroken 2 Waterleakageinthewaterinput valveorthewaterdrainagevalve 1 Tightenthelooseconnectionor changethebrokenpipe 2 Changethewa...

Страница 21: ... 12V 3W 12V 3W TemperatureRange F 50 130 50 130 50 130 50 130 50 130 50 130 50 130 TimeSet Range min 1 60 1 60 1 60 1 60 1 60 1 60 1 60 SteamPress psi 3 4 4 4 5 5 5 SteamVol cu in min 9 11 13 16 19 21 25 SteamSprayTime sec 100 180 180 240 150 210 120 180 170 230 150 160 120 150 Water Vol cu in 80 160 160 160 330 330 330 ApplicableSpaceof the Room cu ft 90 150 225 300 400 450 500 IMPORTANT Thelist ...

Страница 22: ...SteamSpa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com Page 22 INSTALLATION USER GUIDE WIRINGDIAGRAMS 4 5KW Control panel outside room Control panel inside room 240V ...

Страница 23: ...SteamSpa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com Page 23 INSTALLATION USER GUIDE 6KW Control panel outside room Control panel inside room 240V ...

Страница 24: ...SteamSpa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com Page 24 INSTALLATION USER GUIDE 7 5KW 9KW Control panel outside room Control panel inside room 240V ...

Страница 25: ...SteamSpa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com Page 25 INSTALLATION USER GUIDE 10 5KW 12KW Control panel outside room Control panel inside room 240V ...

Страница 26: ...SteamSpa PHONE 800 856 0172 FAX 866 560 5662 http steamspa com info steamspa com Page 26 INSTALLATION USER GUIDE 15KW Control panel outside room Control panel inside room 240V ...

Страница 27: ... thesteam willcomeoutnormally Astimegoeson thetemperaturedisplayedinthecontrolpanelwillrise withthe temperaturein theroombeforeitstopsandstaysatthesettemperature 5 Based on differentrequirementsoftheuserfortemperatureandsteamtime thecontrolpanelcanadjusttemperatureand steam time Whiletestingthemachine setthetimetobe30minutesandthetemperaturetobe120F 6 When theset steamtimeisdue thesystemwillshutof...

Страница 28: ...workagain thedigitaltubewilldisplaycurrentroomtemperaturenormally Whenthesystem ison press buttontoturnoffthesystem orwhenthesteamtimeisover thesystem shutsoff 10minutesafterthesystemisshutoff thedrainagefunctionwillbestarted automaticallyfor 7 minutes TIMEANDTEMPERATURE SETTING Whensystem ison pressbuttontwice systemwillcycleswitchintimesetting TEMPsetting andambient TEMP displaystate Whenthedigi...

Отзывы: