background image

OP

ER

AT

IO

N &

 IN

ST

AL

LA

TI

ON

 M

AN

UA

L

S T E A M  G E N E R AT O R

S T E A M  G E N E R AT O R

a

obsessed with qualiy...

a

quality of life

T M

Auto Drain Equipped   -   Whisper Quiet   -   Quick Start   -   Continous Steam

Содержание SPA II

Страница 1: ...OPERATION INSTALLATION MANUAL STEAM GENERATOR STEAM GENERATOR aobsessed with qualiy aquality of life TM Auto Drain Equipped Whisper Quiet Quick Start Continous Steam...

Страница 2: ...SAUNACORE PHONE 905 951 6662 www saunacore com...

Страница 3: ...re tested and inspected prior to packaging please inspect package when received to assure all is in proper condition If you find any damage to the package immediately put in a claim with the deliverin...

Страница 4: ...y The steam generator has hanging holes in the back side for mounting onto a wall 8 The steam generator requires a minimum of 12 inch clearance of space on both sides top and front 9 The steam generat...

Страница 5: ...nstall all components of the steam generator 4 If steam lines are insulated the insulating materials should be resistant to a temperature of no less then 250F 5 The steam lines should be installed hor...

Страница 6: ...d up within the steam generator Build up of pressure can be created by many different reasons steam line line blockage undersized steam line pipr diameter steam line traps or vandalism This build up o...

Страница 7: ...Controller wire and light wire hole 304mm Safety valve Steam outlet Water inlet Water drainage 2 1 3 m m 1 9 0 m m 11 5 m m 29mm 156mm 260mm 3 0 7 m m 3 1 5 m m 3 3 5 m m 465mm 383mm Fuse for wire po...

Страница 8: ...use for wire power supply metal conduit connector required ELECTRICAL SUPPLY 1 Test the voltage of electricity supplied to the steam generator make sure the correct voltage is supplied to the steam ge...

Страница 9: ...ation refer to national and local electricity consumption codes by professional licensed electricians Attention Warning 240V 1PH 240V 1PH 240V 1PH 240V 1PH 240V 1PH 208V 3PH 240V 1PH 240V 1PH 208V 3PH...

Страница 10: ...rt Pin Black Long Pin Yellow Middle Pin Black Red Blue Brown Red Light J1 1 J1 2 J1 S S Supply Red Red Black To Control Panal Fill water valve Drain water valve Terminal Block Yellow Green Red Black R...

Страница 11: ...Black Red Black Yellow Red Black Red Red Red Red Water Level Sensor Red Short Pin Black Long Pin Yellow Middle Pin Red Black Red Blue Brown Red Light Red Red Supply J2 J3 J2 1 Black J3 1 Black Black...

Страница 12: ...Yellow Middle Pin Red Red Blue Brown Red Light G L1 L2 L3 Red Red J1 2 Red Red J1 1 Red Red J3 2 Red Red J2 To Control Panal Terminal Block J2 2 J1 1 J1 2 J3 1 J2 1 J3 2 J1 J2 J3 Yellow Green Red Bla...

Страница 13: ...of the current steam shower or bathtub area Example L 7xW 5xH 8 280 Cubic Feet You would need a 9000 watt 9KW steam generator However if your shower materials are x 25 for Ceramic Wall Finish 61 25 61...

Страница 14: ...ation must comply with the nation s electric criteria and performed by a professional licensed electrician CAUTION Possible location The steam outlet Under Sink possible location The steam generator L...

Страница 15: ...0 Heating Element Heat Hi limit Transformer 11 12 Terminal block Fuse Ground wire connector 16 Relay Water level sensor 17 15 14 13 Configuration of steam generator Fuse 13 17 9 User Manual Pressure S...

Страница 16: ...with high voltage electric wire Do not install close to hot water or steam pipe Important Before installing the controller make sure the steam generator power is off otherwise the controller may be da...

Страница 17: ...User Manual Control panel both SSI and SSII dimension 113mm 25mm 75mm SSI and SSII Control panel may be switched for Spa II SS I SS I I 160mm 120mm 23mm 70mm 16...

Страница 18: ...operation and convenience of wiring The controller wire is 1 ft long with a supplied 20 ft extension control cable The max length between the generator and the controller should not exceed 20 ft at mo...

Страница 19: ...and press the controller firmly to the wall finish 1 The position of the temperature sensor for the SSI controller should be within a range of 4 5 5 ft 1 2M 1 5M from from the steam room finish floor...

Страница 20: ...When unit is powered on power indicator LED should be lit Press and release button to activate system and all function buttons Meanwhile power indicator LED goes out Water input steam boil tank automa...

Страница 21: ...vated Steam time LED screen shows set time from 5 60 minutes System shuts down power supply to heater elements automatically when desired steam time is over Use and buttons to set desired steam temper...

Страница 22: ...time to keep the temperature in the set number ON OFF When it is electrified the system shuts off all the loads to remain in a waiting state and the digital tube will display as is shown in Fig 1 In t...

Страница 23: ...onment temperature When the system is started press button or when the steam function time is due the system will be shut 10 minutes after the system is shut off the drainage function will be started...

Страница 24: ...mpletion of the automatic water discharge after each time using the steam generator to make sure the water in the tank is discharged completely before cutting off the power supply 3 There should not b...

Страница 25: ...ur new Saunacore steam unit with the advanced IntelliSteam controller This booklet will help you get the most enjoyment out of your device s many capabilities and features Steamcore IntelliSteam Opera...

Страница 26: ...ouched for 20 seconds the system will auto lock the keypad and the Dotted line Solid line indicator on the display screen will flash Touching the Power Key for 3 seconds will unlock the system making...

Страница 27: ...uner A third touch shuts the CD function off completely If no CD is installed touching the Radio key a second time will simply turn off the radio function 9 Radio Tuning Search Power on radio function...

Страница 28: ...ecting touch the Bluetooth Now you can use Bluetooth to play music or answer a call Touching the Up key skips to the next song and touching the Down key skips back to the previous one Touch TUN TEL to...

Страница 29: ...This set of instruction pages is to be used in combination with the Steamcore Steam Bath installation manual provided with each steam bath generator 28...

Страница 30: ...tween the control panel and the electrically controlled box has become loose and whether the power circuitry has good contact 2 Change a plugboard Water leakage 1 The water pipe connector becomes loos...

Страница 31: ...anual Min 208V 3PH 240V 1PH 208V 3PH 240V 1PH 12 5A 18 75A 25A x 3 31 25A 37 5A 43 75A 33 3A x 337 5A x 341 7A x 3 50A x 3 25A 50A 12V 40W 12V 40W12V 40W12V 40W 12V 40W 12V 40W 12V 40W 12V 40W 12V 40W...

Страница 32: ...____________________________________ Dealer Name and Adress ____________________________________________________________________________________________ Owner Name and Address ________________________...

Отзывы: