6
OPERATIONAL INSTRUCTIONS FOR TERMINATOR
1.
Connect power cable to 240v socket inlet ( Fig 1 # 1)
2.
Connect the male end of solution hose (Fig 8) to the solution outlet on machine (Fig2)
3.
Connect the female soltuion hose end to the male connection of the wand trigger (Fig 9)
4.
Take the G-vac hose (Fig7) & connect to the wand end & the inlet on the dome.
5.
Fill unit with hot or cold water Note Do not exceed 50 degrees celcius for hot water as this will
weaken & damage internal pump seals.
6.
Engage both vac switches & pump switches to start operation. Depress brass trigger to release
water & cleaning has begun.
TROUBLE SHOOTING GUIDE
LACK OF VACUUM
Check that the dump valve is closed & sealing,
Ensure dome lid is seated correctly & tightly sealed
Check that both vac motors are working & switched are illuminated red.
Check waste tank float cage to ensure ball is not trapped in the up position
Check wand mouth to ensure it is not obstructed.
Check suction hose for any holes or splitting.
LOW OR FLUCTUATING PRESSURE
Check sufficient water levels.
Check the pump switch to ensure power is available
Check wand jets for blockages.
Check that solution filter in rear tank is clean & free from any obstructions.