OPERATIONAL INSTRUCTIONS FOR TERMINATOR 

1.

Connect power cable to 240v socket inlet ( Fig 1 # 1)

2.

Connect the male end of solution hose (Fig 8)  to the solution outlet on machine (Fig2)

3.

Connect the female soltuion hose end to the male connection of the wand trigger (Fig 9)

4.

Take the G-vac hose (Fig7) & connect to the wand end & the inlet on the dome.

5.

Fill unit with hot or cold water Note Do not exceed 50 degrees celcius for hot water as this will
weaken & damage internal pump seals.

6.

Engage both vac switches & pump switches to start operation. Depress brass trigger to release
water & cleaning has begun.

TROUBLE SHOOTING GUIDE 

LACK OF VACUUM 

Check that the dump valve is closed & sealing,

Ensure dome lid is seated correctly & tightly sealed

Check that both vac motors are working & switched are illuminated red.

Check waste tank float cage to ensure ball is not trapped in the up position

Check wand mouth to ensure it is not obstructed.

Check suction hose for any holes or splitting.

LOW OR FLUCTUATING PRESSURE 

Check sufficient water levels.

Check the pump switch to ensure power is available

Check wand jets for blockages.

Check that solution filter in rear tank is clean & free from any obstructions.

Steamaster | 6 Reservoir Avenue Greenacre Sydney NSW 2190 Australia | Tel: 1300 855 677 | Tel: +61 2 9796 3433 | Fax: +61 2 9796 3395 | www.steamaster.com.au

Содержание POLIVAC TERMINATOR

Страница 1: ...1 POLIVAC TERMINATOR OPERATIONS MANUAL TROUBLE SHOOTING GUIDE Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au...

Страница 2: ...um sub frame Switches 3 x Red self illuminating push button switches Water capacity Solution tank 55 litres Recovery tank 20 litres Standard cleaning equipment included 1 x 5 mtr solution hose 1 x 5 m...

Страница 3: ...3 Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au How to Use Your Polivac Terminator Click on The Video to Watch Now...

Страница 4: ...inator The mesh cage houses the cut off float preventing waste water from entering the vac motors This is the working position of the float The Aluminium deflection plate stop water spray mist from en...

Страница 5: ...alve is completely closed before operation to obtain maximum suction The above picture shows the exhaust point for the vacuum motors If at any stage the operator experiences water coming from this poi...

Страница 6: ...r to release water cleaning has begun TROUBLE SHOOTING GUIDE LACK OF VACUUM Check that the dump valve is closed sealing Ensure dome lid is seated correctly tightly sealed Check that both vac motors ar...

Страница 7: ...7 Steamaster 6ReservoirAvenueGreenacreSydneyNSW2190Australia Tel 1300855677 Tel 61297963433 Fax 61297963395 www steamaster com au Click on The Video to Watch Now...

Отзывы: