Rev 3/2012
18 |
P a g e
Part 2
Safety Notes:
1.
The power supply must be installed according to the local standard and with GFCI
(Ground Fault Current Interrupter). Test the GFCI before using to confirm its security
and validity
2.
The ground for electrical appliances should be connected to fixed earth wire forever.
3.
To avoid electric shock, replacing the power supply wire should be done by a
professional electrician or distributor. Users should not change it by themselves.
4.
To avoid shock, no extension power line should be used. The socket should be in the
right position. Broken electric wire should be changed in time.
5.
It is forbidden to make any change, adding, or cutting to the product.
6.
It is forbidden to use the product while intoxicated.
7.
Children should us the product under adult supervision.
8.
Adjust the water temperature slowly from colder to warmer to avoid being scalded.
9.
Stop using the product if you feel uncomfortable.
Parameter for Steam Cabin:
Rated Power:
3.0KW
Rated Voltage:
Double Phase AC240V
Rated Electric Current:
16A
Frequency:
50Hz
Power Supply:
On Wall
Rated Water Pressure:
0.2 – 0.6MPa
Water Supply:
DN 15 tie-in, hot/cold water
Water Supply Location:
On Floor
Diameter of Drainage Pipe:
Φ50 (drainage pipe supplied with product)
Length of Drainage Pipe:
1000mm (the maximum length after streched)
Содержание WS-112
Страница 4: ...Rev 3 2012 4 P a g e ...
Страница 11: ...Rev 3 2012 11 P a g e Install the front fixed glass ...
Страница 12: ...Rev 3 2012 12 P a g e Install the glass door with hinges ...
Страница 13: ...Rev 3 2012 13 P a g e Install the door handle adjustable handheld shower bar ...
Страница 15: ...Rev 3 2012 15 P a g e Install the aluminum trim ...
Страница 19: ...Rev 3 2012 19 P a g e Electrical Diagram for Control Box ...
Страница 20: ...Rev 3 2012 20 P a g e S6 Wiring Diagram ...
Страница 27: ...Rev 3 2012 27 P a g e ...
Страница 29: ...Rev 3 2012 29 P a g e ...