Precautions
WARNING
All wiring terminal strips and connection boxes must be
easily accessible for installation and service.
For the air conditioner without plug, an circuit breaker
must be installed and easily accessible.
To avoid personal injury or damage, if you need to
relocate the air conditioner, only a qualified licensed
technician should perform the work.
Select a location out of reach for children and far away
from animals or plants. If it is unavoidable, please add
a fence for safety purposes.
The indoor unit should be installed close to the wall.
Instructions for installation and use of this product are
provided by the manufacturer.
If the unit is off for an extended period at
-
5°F or lower
outside ambient temperature, power-on the unit for 4
hours or more to preheat before starting.
Working temperature range
NOTICE:
Indoor side DB/WB(
℃
/°F) Outdoor side DB/WB(
℃
/°F)
Maximum cooling
27/19(8
1
/66)
46/24(11
5
/75)
Maximum heating
27/
81)
24/18(75/64)
● The operating temperature range (outdoor temperature) for cooling only unit is
-18
℃
~ 46
℃
(0 ~ 11
5
°F)
; for heat pump unit is -35
℃
~ 46
℃
(-31 ~ 11
5
°F).