SIGNALS AND SPECIAL FEATURES
4. Signals and Special
Features
4.1 Power-LED
4.2 Battery-LED (green)
4.3 Battery-LED (red)
4.4 Levelling-LED for X-/Phi-axis
Permanently lit
Laser is turned on, no errors
•
5Hz-Flash
Error
•
(Power problem, boot sector error, end of position
reached ...)
Power-On- / Power-Off-Sequence
•
Permanently lit
Supply voltage sufficient
•
5Hz-Flash
Power-On- / Power-Off-Sequence
•
1Hz-Flash
Supply voltage below minimum threshold
•
Permanently lit
Axis is in levelling mode
•
5Hz-Flash
Power-On- / Power-Off-Sequence
•
Levelling not possible, outside of measurement range
•
1Hz-Flash
Temperature drift too large (usually during warm-up) – WAIT
•