3
3.
Bedienungselemente
4th getting started
a) Connection
Connect the net plug of the electricity supply device with a 230outlet VAC and switch on the device with the net counter.
The control - LED "ON" lights up.
temperature protection attention
At longer company with max. stream with small source tension or with short circuit the chill body in the device becomes
very warm. With temperature protection of the chill body the device switches off itself independently (tension
announcement (7) goes on value 0V). After an cooling from approx. 2-3min, the device can be started running by
switching off and again turning on (6) once more.
b) Setting of the source tension
Put the source tension by means of the set button on the desired value. The announcement of the tension occurs in the
installation instrument.
c) Connection of the load
To the apparatus clips security pipelines with plug 4 mms or pipelines can be clamped. Pay attention to properly
connection of the consumer.
Attention
Follow absolutely the security tips under segment 2 of these instructions.
Care! Combustion danger!
Pay attention, hence, absolutely to a sufficient ventilation of the electricity supply device and never cover them the
ventilation slits on the device waiter - or device underside to avoid possible damages.
5. technical data
Net voltage
: 230 VAC +6/-10%
Net frequency
: 50 bis 60 Hz
Net power
: max. 40 W
output voltage
: 1,5V - 15V DC
output current
: max.1,5A
CV - ripple
: 10mVeff
fuse
: 200 mA T
wig
: ca. 1,5 kg
dimensions ( B x H x T )
: 110 x 80 x 150
Surroundings conditions
temperature for working
: +10 °C bis +35 °C
temperature range relative atmospheric humidity
: max. 85 %
air pressure
: 800 bis 1333 hPa
1. socket plus
2.
socket minus
3.
net cable
4.
LED
5. Set button
6. net switch
7. analog display