5. Exterior, Names and Functions of Components

Diagram of Setting/Display Panel

5-1 Explanation of Main Unit Components

#
1
2

3

4

5
6
7
8
9

10
11
12
13
14

15

Description

Insert the work to eliminate static charges and clean.
Detach this when cleaning the inside of the main unit. When detaching, remove the knurled

screws (one on each side) in the sides of the main unit for holding this floor in place.
Replaceable filter to trap particles
Two blow nozzles are arranged at the top and one at the bottom. The angles of the two blow

nozzles at the top are adjustable, and their angles can be adjusted as desired to match the shape

of the work piece.
A static elimination ionizer nozzle
Display the air blow pressure. This device can be used within the range of 29 to 87 psi.
Displays the various settings and operations. Details are described below.
A connector for supplying AC power. Connect the supplied power cable here.
A terminal for grounding. You can connect an M4 terminal.
The power supply fuse box.

A coupler for connecting compressed air. Connect using a 1/4" ID(min) air supply line/pipe.

For sensor 'Eye' connection
Detect the work object and start air blow
Filter with 5-micron element and condensate bowl
Mist-Separator Filter with 0.3-micron element and condensate bowl

3

Work inlet

Main unit perforated floor

Filter

Blow nozzle

Ionizer

Air pressure gauge

Setting/Display Panel

Power cord inlet

Ground terminal

Fuse box

1

/

4

" quick coupler

Terminal Strip

Sensor "Eye"

Primary Filter

Secondary Filter

Component

Содержание Particle Trap Cube

Страница 1: ...wires tools etc It may cause electrical shock or damage Because the tip of the emitter pin is sharp take sufficient care when handling it It may cause injuries Do not under any circumstances disassemb...

Страница 2: ...uction Manual This document Qty 1 Power cord Qty 1 Work inlet covers Qty 3 Replacement filter Qty 1 3 8 NPT Male x Female Elbow Nickel Plated Qty 1 3 8 NPT Male x Industrial Quick Disconnect Fitting Q...

Страница 3: ...e of the work piece A static elimination ionizer nozzle Display the air blow pressure This device can be used within the range of 29 to 87 psi Displays the various settings and operations Details are...

Страница 4: ...en this is illuminated the device will not operate until reset This is illuminated when a work piece is detected and air is blowing It blinks at the pulse speed when the Blow Mode setting is set to Pu...

Страница 5: ...r 7 Operation 7 1 Procedure When Starting Operation Install the device in a location with a flat top and carry out wiring and air connection Open the compressor valve and supply air to the device Oper...

Страница 6: ...FLT replacement filters sold in packages of 5 If by chance water or oil lands on the device despite having installed it in a water and oil free location switch off the power as soon as possible and wi...

Страница 7: ...the emitter pin and any other dirty parts with a Q tip dampened with IPA isopropyl alcohol Dry the alcohol sufficiently after cleaning 8 3 Workspace Cleaning Procedure Depending on the usage condition...

Страница 8: ...mp is illuminated The neutralizing effect is unsatisfactory Check whether the emitter pin or its surroundings are dirty Check that the ground of the device is reliably grounded Check that there is no...

Отзывы: