R E S I D E N T I A L

SELECT 

DIRECT-VENT 

Residential Gas Water Heaters 

For more information on Select 

® 

 contact: 

State Water Heaters 

500 Tennessee Waltz Parkway, Ashland City, TN 37015 

800-365-0024 Toll-free USA 

www.statewaterheaters.com 

SRGSS02207            June 2011R                                   

For complete information on limited warranties,  
consult written warranty, or contact the State  
Customer Care Center, 1-800-365-0024. 
 

Recoveries are rounded to nearest gallon 
Water Connections - 3/4” on all models 

**

Dual-channel system has 3” vent pipe inside 6” air intake pipe for the 40 & 50-gallon. The 75-gallon models uses a 4” x 7” Co-Axial pipe. 

***

A dimension is to center line of flue (recommended vent height) 

When ordering Propane, change “

Y

” to “

H

” in model number (GS6 40 

H

BDS) 

All models have 2” foam cavity 
75-gallon water connections are 12” on center. 

 

MODEL 

NUMBER 

FIRST 

HOUR 

RATING 

ENERGY 

FACTOR 

GALLON 

CAP 

BTU 

INPUT 

RECOVERY 

90 DEGREE 

RISE 

A

*** 

DIMENSIONS 

VENT  

PIPE

** 

SHIPPING 

WEIGHT 

GS6 40 YBDS 

GS6 50 YBDS 

GS6 50 YRDS 

73 

87 

88 

0.62 

0.60 

0.59 

40 

50 

50 

38,000 

42,000 

50,000 

41 

45 

55 

Co-Axial 

Co-Axial 

Co-Axial 

167 

185 

187 

68 

76 

76 

54-3/4 

63-3/4 

64-3/4 

22-1/4 

22-1/4 

22-1/4 

16 

16 

16-1/4 

12-1/4 

12-1/4 

12-1/2 

45-1/4 

54 

55-1/2 

 

E

F

B

A

D

FRONT 

MAX VENT 

80 

C

EXTERIOR 

WALL 

6“ DIA. ON 40 & 50-GALLON MODELS 

7” DIA. ON 75-GALLON MODELS 

MIN VENT 

17 

42° 

47° 

25-1/4 for 

40 & 50-gallon 

29-1/2 for 
75-gallon 

TOP 

Important! Vent Installation and Termination Requirements 

• Maximum horizontal vent distance is 80” to outside of exterior wall. 
• Minimum horizontal vent distance is 17” to outside of exterior wall. 
• Vent pipes may be trimmed (cut) for short vent installations. 
• For vent installation less than 30” the vent restrictor is required. Place     

restrictor over the flue outlet on heater before installing the outlet vent  
pipe to the heater. 

• Recommended installation height for the heater and vent pipe should be  

68” for 40-gallon models and 76” for the 50 and 75-gallon models (vent  
height).  

• Offset Vent Arrangement 

1. When replacing an existing direct vent model, the new vent pipe may drop 

from the minimum vent height as much as 7 1/4” to exit through the  
existing vent opening in the exterior wall. 

2. Vent may have one horizontal 90 degree turn before exiting through  

exterior wall (Do not combine both offset vent arrangements in one  
installation) (See examples in the installation manual) 

• High Rise Vent Arrangement 

3. When vent termination is more than 80” above the base of the heater.  

The horizontal vent run must be a minimum of 22” from the center of the 
heater to the outside exterior wall surface. (See example in the  
installation manual) 

• Vent termination clearance hole through the exterior wall should be  

approximately 7” diameter. 

• Snow accumulation and drifting should be considered when locating the  

termination. 

• An optional wire grill vent cap protector is available through the parts  

department. Request part  number 9006627. 

• See the installation manual for complete installation and venting  

requirements.  

55,000 

GS6 75 YRDS 

131 

0.59 

75 

60 

76 

65-3/4 

26-1/4 16-1/4 12-1/2 

55-1/2 

310 

Co-Axial 

 

75-GALLON VENT  

TERMINATION CAP  

IS NOT  

INTERCHANGEABLE  

WITH THE VENT  

CAP ON THE  

40 & 50-GALLON  

MODELS. 

237691_SRGSS02207.indd   2

237691_SRGSS02207.indd   2

6/28/11   10:04 AM