State Water Heaters GS6 40 YBDS Скачать руководство пользователя страница 2

R E S I D E N T I A L

SELECT

DIRECT-VENT

Residential Gas Water Heaters

For more information on Select

®

 contact:

State Water Heaters

500 Tennessee Waltz Parkway, Ashland City, TN 37015

800-365-0024 Toll-free USA

www.statewaterheaters.com

SRGSS02207            May 2008R                                   

For complete information on limited warranties, 
consult written warranty, or contact the State 
Customer Care Center, 1-800-365-0024.

Recoveries are rounded to nearest gallon
Water Connections - 3/4” on all models

**

Dual-channel system has 3” vent pipe inside 6” air intake pipe for the 40 & 50-gallon. The 75-gallon models uses a 4” x 7” Co-Axial pipe.

***

A dimension is to center line of flue (recommended vent height)

When ordering Propane, change “

Y

” to “

H

” in model number (GS6 40 

H

BDS)

All models have 2” foam cavity
75-gallon water connections are 12” on center.

MODEL

NUMBER

FIRST

HOUR

RATING

ENERGY

FACTOR

GALLON

CAP

BTU

INPUT

RECOVERY

90 DEGREE

RISE

A

***

C

B

D

E

F

DIMENSIONS

VENT 

PIPE

**

SHIPPING

WEIGHT

GS6 40 YBDS

GS6 50 YBDS

GS6 50 YRDS

73

87

88

0.62

0.60

0.59

40

50

50

38,000

42,000

50,000

41

45

55

Co-Axial

Co-Axial

Co-Axial

167

185

187

68

76

76

54-3/4

63-3/4

64-3/4

22-1/4

22-1/4

22-1/4

16

16

16-1/4

12-1/4

12-1/4

12-1/2

45-1/4

54

55-1/2

E

F

B

A

D

FRONT

MAX VENT

80

C

EXTERIOR

WALL

6“ DIA. ON 40 & 50-GALLON MODELS

7” DIA. ON 75-GALLON MODELS

MIN VENT

17

42°

47°

25-1/4 for

40 & 50-gallon

29-1/2 for
75-gallon

TOP

N

I

A

R

D

P

&

T

Important! Vent Installation and Termination Requirements

• Maximum horizontal vent distance is 80” to outside of exterior wall.
• Minimum horizontal vent distance is 17” to outside of exterior wall.
• Vent pipes may be trimmed (cut) for short vent installations.
• For vent installation less than 30” the vent restrictor is required. Place    

restrictor over the flue outlet on heater before installing the outlet vent 
pipe to the heater.

• Recommended installation height for the heater and vent pipe should be 

68” for 40-gallon models and 76” for the 50 and 75-gallon models (vent 
height). 

• Offset Vent Arrangement

1. When replacing an existing direct vent model, the new vent pipe may drop

from the minimum vent height as much as 7 1/4” to exit through the 
existing vent opening in the exterior wall.

2. Vent may have one horizontal 90 degree turn before exiting through 

exterior wall (Do not combine both offset vent arrangements in one 
installation) (See examples in the installation manual)

• High Rise Vent Arrangement

3. When vent termination is more than 80” above the base of the heater. 

The horizontal vent run must be a minimum of 22” from the center of the
heater to the outside exterior wall surface. (See example in the 
installation manual)

• Vent termination clearance hole through the exterior wall should be 

approximately 7” diameter.

• Snow accumulation and drifting should be considered when locating the 

termination.

• An optional wire grill vent cap protector is available through the parts 

department. Request part  number 9006627.

• See the installation manual for complete installation and venting 

requirements. 

55,000

GS6 75 YRDS

131

0.59

75

60

76

65-3/4

26-1/4

16-1/4

12-1/2

55-1/2

310

Co-Axial

75-GALLON VENT 

TERMINATION CAP 

IS NOT 

INTERCHANGEABLE 

WITH THE VENT 

CAP ON THE 

40 & 50-GALLON 

MODELS.

195224_SRGSS02207.indd   2

5/14/08   11:02:53 AM

Отзывы: