7.  If  the  Ignition  Control  does  not  sense  the  flame  during  the

 

 

4 second ignition trial period, the Ignition Control shuts the Gas

 

 

Valve and turns off the Spark Igniter. The control is locked out,

 

 

the  power  to  the  unit  must  be  cycled  to  restart  the  Ignition

 

 

Control.

8.  If  the ignition control senses flame during the 4 seconds trial for 

ignition period, the gas control remains open and the burner on 

until the call for heat ends.

9.  The Ignition Control monitors the Flame Sensor during the

 

heating cycle. If the flame signal is lost, the Ignition Control shuts

 

the  main  Gas  Valve  and  re-starts  the  ignition  process  at 

step 4.

10. Once  the  unit  is  satisfied,  the  Ignition  Control  will  shut  off  the

 

 

main Gas Valve and the unit will be in standby mode until another

 

 

call for heat is initiated by the thermostat.

See the flow chart on page 24 for more information.

•  Attach  a  gas  pressure  gauge  or  manometer  to  upstream  side

 

  of main gas cock and a gas pressure gauge or manometer to

 

  the manifold pressure tapping.
•  Check  voltage  at  disconnect  switch  to  make  certain    that    it

 

  matches that shown on the burner label.
•  Apply  a  few  drops  of  No.  20  SAe  non-detergent  oil  to  the

 

  motor bearings.
•  Drill  max.  5/16"  hole  in  breeching  as  close  as  possible  to  flue

 

  connection  on  heater  to  install  stack  thermometer  and

 

  combustion analyzing equipment.  (See Figure 11).
•  you are now ready to begin the burner start up procedure.
Installation  and  start  up  of  this  water  heater  requires  abilities  and 

skills equivalent to that of a licensed tradesman in the field involved, 

see qualifications on page 6.
Do not place the water heater in operation if any part has been under 

water. Immediately call a qualified service technician to inspect the 

water heater and to replace any part of the control system and any 

gas control which has been under water. 
light the water heater in accordance with the lighting and Operation 

Instruction label on the water heater and in this manual on pages 25. 
Before  attempting  start  up,  thoroughly  study  and  know  the  exact 

Sequence  Of  Operation.  See  written  Sequence  Of  Operation  on 

page 23 and Sequence Of Operation Flow Chart on page 24.
Be certain that the water heater is full of water, that air is purged from 

the gas and water lines and that there are no leaks in the gas and 

water lines. ensure all inlet water valves are open.

filling the water heater

Follow these steps to fill the water heater prior to start up.
1.  Close the heater drain valve.
2.  Open a nearby hot water faucet to permit air in system to escape.
3.  Fully  open  the  cold  water  inlet  valve  allowing  the  piping  and

 

  water heater to fill with water.
4.  Close hot water faucet opened in Step 2 as water starts to flow.
read SequeNCe OF OPerATION section of this manual prior 

to lighting and operating this water heater.
With above conditions satisfied, start the unit in accordance with the 

instructions on the operating label attached to the heater. For your 

convenience a copy of the instructions are shown on pages 25.

Fire or Explosion Hazard

Read instruction manual before

installing, using or servicing

water heater.

To avoid risk of fire or explosion purge discharge must not

enter into confined areas or spaces where ignition can occur.

The area must be well ventilated and all sources of ignition

must be deactivated or removed.

Gas line purging is required with new piping or systems in

which air has entered.

prior to start up

This  product  requires  a  formal  Start-up  by  an  authorized  service/ 

start-up  provider  that  has  been  approved  by  the  manufacturer  for 

this  specific  product.  Call  1-800-527-1953  to  locate  the  nearest 

authorized start-up provider and arrange a factory start-up. Please 

provide  as  much  notice  as  possible,  preferably  2  weeks.  Please 

have the model and serial number ready when you call.
This start-up is required to activate the warranty and ensure safe, 

efficient operation.
Warranty on this product is limited and could be void in the event 

the unit is not installed per the instructions in this manual and/or not 

started up by an authorized factory trained service/start-up provider.
The following test equipment should be on hand: (all test equipment 

must be acclimated to ambient temperature before calibration and use.)
1.  CO2 indicator (Fyrite or similar) or O2 analyzer

2.  CO indicator (monoxor or similar)

3.  Stack thermometer

4.  Draft Gauge or inclined manometer

5.  Two  u-tube  manometers  or  calibrated  0-10"  and  0-35"  w.c.

 

  pressure gauges.

6.  Combination volt/ammeter.

start-up and operation

seQuence of operation

The following information will describe the Sequence of Operation 

for this water heater.
1.  Switch power on to unit.
2.  Thermostat calls for heat.
3.  On  a  call  for  heat,  24V  is  applied  to  motor  start  relay  and  air

 

 

switch. Once the fan motor reaches operating rpm combustion

 

 

air pressure is sensed by the air proving switch and closes the

 

 

switch contacts energizing the S89 ignition module. The ignition

 

 

module performs diagnostic self check on system components.

4.  The Ignition Control begins the trial for ignition after 30 seconds 

prepurge is completed.

5.  The Ignition Control turns on the Spark Igniter and opens the Pilot

 

 

Gas Valve.

6.  The Ignition Control monitors the Flame Sensor during the ignition

 

 

trial period.

Содержание GPG 81-140

Страница 1: ...nergy efficient water heater We appreciate your confidence in our products WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any applia...

Страница 2: ...grams 35 49 MANIFOLD KITS 50 replacement parts list 51 52 Notes 53 54 Warranty 55 Table Of Contents Safe Installation Use and Service 3 Approvals 3 General Safety Information 4 5 Precautions 5 Grounding Instructions 5 Hydrogen Gas Flammable 5 Introduction 6 Abbreviations Used 6 Qualifications 6 Start Up Requirements 6 Preparing for the Installation 6 Features And Components 7 High Limit Switch 7 E...

Страница 3: ...other reproductive harm and requires businesses to warn of potential exposure to such substances WARNING This product contains a chemical known to the State of California to cause cancer birth defects or other reproductive harm This appliance can cause low level exposure to some of the substances listed in the Act DANGER WARNING CAUTION CAUTION DANGER indicates an imminently hazardous situation wh...

Страница 4: ...tion Contact a qualified installer or service agency for installation and service Excessive gas pressure to gas valve can cause serious injury or death Do not use water heater with any gas other than the gas shown on the rating label Turn off power to the water heater before performing any service Electrical Shock Hazard Label all wires prior to disconnecting when performing service Wiring errors ...

Страница 5: ...ater system If hydrogen is present there will probably be an unusual sound such as air escaping through the pipe as the water begins to flow There should be no smoking or open flame near the faucet at the time it is open General Safety Information Verify the power to the water heater is turned off before performing any service procedures Read and understand this instruction manual and the safety m...

Страница 6: ...ct is limited and could be void in the event the unit is not installed per the instructions in this manual and or not started up by an authorized factory trained service start up provider Preparing For The Installation 1 Read the General Safety section page 4 5 of this manual first and then the entire manual carefully If you don t follow the safety rules the water heater will not operate properly ...

Страница 7: ...e water heater IGNITION MODULE FIGURE 2 BAROMETRIC DRAFT CONTROL The heater is equipped with a double acting barometric draft control This control assembly is factory adjusted to automatically regulate the chimney draft imposed on the unit BAROMETRIC DRAFT CONTROL FIGURE 3 COMBUSTION CHAMBER OBSERVATION PORT The combustion chamber observation access panel is located above and to the left of the bu...

Страница 8: ...P WT LBS IN OUT ASME STD GPG 81 140 74 3 4 65 26 3 4 6 21 3 8 27 3 4 38 85 1 4 1 2 658 556 1 1 2 1 1 2 GPG 81 199 74 3 4 65 26 3 4 6 21 3 8 27 3 4 38 85 1 4 1 2 635 545 1 1 2 1 1 2 GPG 81 270 74 3 4 65 26 3 4 8 21 3 8 27 3 4 38 85 1 4 3 4 632 547 1 1 2 1 1 2 GPG 81 370 74 3 4 65 26 3 4 8 21 3 8 27 3 4 38 85 1 4 3 4 731 634 1 1 2 1 1 2 ...

Страница 9: ...9 256 5 Models with letter A following the model number have the optional ASME tank construction The GPG 81 370 is available in natural gas only TABLE 3 GAS AND ELECTRICAL CHARACTERISTICS Model Type of Gas Gas Supply Pressure Gas Manifold Pressure Volts Hz Amperes Minimum Maximum All Models Natural 4 5 W C 1 12 kPa 14 W C 3 48 kPa 3 5 W C 0 87 kPa 120 60 5 All Models Propane 4 5 W C 1 12 kPa 14 W ...

Страница 10: ...24 cm 24 60 96 cm locating the water heater Property Damage Hazard All water heaters eventually leak Do not install without adequate drainage CAUTION When installing the heater consideration must be given to proper location Location selected should be as close to the stack or chimney as practicable with adequate air supply and as centralized with the piping system as possible Fire or Explosion Haz...

Страница 11: ...tions exist water softening or the threshold type of water treatment is recommended This will protect the dishwashers coffee urns water heaters water piping and other equipment See the Maintenance Section in this manual for sediment and lime scale removal procedures Circulation pumps A circulating pump is used when a system requires a circulating loop or there is a storage tank used in conjunction...

Страница 12: ...eet 1219m you subtract 4 once for each thousand feet x 04 4 input reduction x 78 000 original rating from the original rating Therefore to calculate the input rating at 4 000 feet 1219m 4 x 04 x 78 000 12 480 Btuh 3 7 Kwh 78 000 22 9 Kwh 12 480 3 7 Kwh 65 520 Btuh 19 2 Kwh At 6000 feet 1829m the correct input rating should be 59 280 Btuh 17 4 Kwh CIRCULATING PUMP WIRING DIAGRAM STORAGE TANK OR BUI...

Страница 13: ...g at maximum rate dynamic pressure The gas supply pressure must be stable within 1 5 W C from static to dynamic pressure to provide good performance Pressure drops that exceed 1 5 W C may cause rough starting noisy combustion or nuisance outages Increases or spikes in static pressure during off cycles may cause failure to ignite or in severe cases damage to appliance gas valves If your low pressur...

Страница 14: ...the Water Piping Diagrams beginning on page 35 Temperature pressure relief valve Explosion Hazard Temperature Pressure Relief Valve must comply with ANSI Z21 22 CSA 4 4 and ASME code Properly sized temperature pressure relief valve must be installed in opening provided Can result in overheating and excessive tank pressure Can cause serious injury or death This water heater is provided with a prope...

Страница 15: ... Pressure Relief Valve call the toll free number listed on the back cover of this manual for technical assistance Contaminated Air Breathing Hazard Carbon Monoxide Gas Install water heater in accordance with the Instruction Manual and NFPA 54 or CAN CSA B149 1 To avoid injury combustion and ventilation air must be taken from outdoors Do not place chemical vapor emitting products near water heater ...

Страница 16: ...ce A Confined Space is one whose volume is less than 50 cubic feet per 1 000 Btu hr 4 8 cubic meters per kW of the total input rating of all appliances installed in the space Openings must be installed to provide fresh air for combustion ventilation and dilution in confined spaces The required size for the openings is dependent on the method used to provide fresh air to the confined space and the ...

Страница 17: ...inches 300 mm of the top of the enclosure shall be provided See Figure 12 The water heater shall have clearances of at least 1 inch 25 mm from the sides and back and 6 inches l50 mm from the front of the water heater The opening shall directly communicate with the outdoors or shall communicate through a vertical or horizontal duct to the outdoors or spaces that freely communicate with the outdoors...

Страница 18: ...he aggregate input rating of all appliances installed in the enclosure Each opening shall not be less than 100 square inches 645 cm2 Outdoor Air Through Two Vertical Ducts The illustrations shown in this section of the manual are a reference for the openings that provide fresh air into confined spaces only Do not refer to these illustrations for the purpose of vent installation See Venting Install...

Страница 19: ... on the water heater each remote storage tank that may be installed and piped to a water heating appliance must also have its own properly sized rated and approved Temperature Pressure Relief Valve installed Call the toll free technical support phone number listed on the back cover of this manual for further assistance in sizing a T P valve for remote storage tanks T P Valve Discharge Pipe Explosi...

Страница 20: ... recommended that the discharge pipe be terminated at an adequate drain inside the building Shall not have any valve or other obstruction between the relief valve and the drain Installation Diagrams Top Inlet Outlet Usage Use of the top inlet water connection requires an inlet dip tube refer to Figure 17 The tube is supplied in the heater Follow caution labels if applying heat to this fitting Do n...

Страница 21: ...ing jurisdiction AN ELECTRICAL GROUND IS REQUIRED TO REDUCE RISK OF ELECTRICAL SHOCK OR POSSIBLE ELECTROCUTION If any of the original wire as supplied with the water heater must be replaced use only type 105 C thermoplastic or equivalent 2500 C type F must be used for the flame sensor and igniter leads The controls of this water heater are polarity sensitive Be certain to properly wire the hot and...

Страница 22: ...s in gas ways Such fouling may cause improper operation fire or explosion If copper supply lines are used they must be internally tinned and certified for gas service Before attaching the gas line be sure that all gas pipe is clean on the inside To trap any dirt or foreign material in the gas supply line a sediment trap must be incorporated in the piping see Figure 20 The sediment trap must be rea...

Страница 23: ... escape 3 Fully open the cold water inlet valve allowing the piping and water heater to fill with water 4 Close hot water faucet opened in Step 2 as water starts to flow Read SEQUENCE OF OPERATION section of this manual prior to lighting and operating this water heater With above conditions satisfied start the unit in accordance with the instructions on the operating label attached to the heater F...

Страница 24: ...ET IF NO SPARK S89 LOCKS OUT AND SHUTS DOWN SYSTEM MUST BE RESET IF FLAME SIMULATION CONDITION IS PRESENT SYSTEM WILL NOT START POWER INTERUPTION SYSTEM SHUTS OFF RESTARTS WHEN POWER IS RESTORED SAFE START CHECK VALVE ON DELAY 30S PREPURGE COMBUSTION AIR BLOWER STARTS SPARK GENERATOR POWERED IGNITION BEGINS AND GAS CONTROL OPENS BURNER LIGHTS IGNITION STOPS AND FLAME CURRENT IS SENSED BURNER RUNS ...

Страница 25: ...25 LIGHTING OPERATION LABEL Figure 21 Label for Natural AND LP Gas Models ...

Страница 26: ...to assure proper venting and correct combustion CHECKING THE INPUT For installation locations with elevations above 2000 feet refer to HIGH ALTITUDE INSTALLATIONS section of this manual for input reduction procedure The input rate can be estimated by timing the meter if no other appliances are operating With a stopwatch or a wristwatch which can display the time in seconds read the gas meter and m...

Страница 27: ...est of the flue gases with an Orsat or other similar combustion test equipment If the CO2 content is within range see Table 9 no adjustment of the air shutter is required Flue gas temperature and CO2 measurements should be repeated 3 times to ensure accurate readings Check the flue gas temperature ahead of the barometric damper See Table 9 net temp gross temp ambient temp Check breeching pressure ...

Страница 28: ... the limited warranty Thermal expansion tanks must be installed on all closed water systems DO NOT PLUG THE TEMPERATURE PRESSURE RELIEF VALVE OPENING THIS CAN CAUSE PROPERTY DAMAGE SERIOUS INJURY OR DEATH venting system and BAROMETRIC DRAFT CONTROL The heater is equipped with a double acting barometric draft control This control assembly is factory adjusted to automatically regulate the chimney dr...

Страница 29: ...o reduces efficiency of the heater and increases fuel consumption The usage of water softening equipment greatly reduces the hardness of the water However this equipment does not always removeallofthehardness lime Forthisreasonitisrecommended that a regular schedule for deliming be maintained The time between cleaning will vary from weeks to months depending upon water conditions and usage The dep...

Страница 30: ... the tank due to a by pass problem or defective cold water inlet valve Also check for clogged drain valve opening Heater must be completely drained before introducing UN LIME 8 Remove the cleanout cover and place a clean plastic bucket next to the cleanout opening Partially open the cold water inlet valve to allow time to accomplish the following and then close the valve Figure 25 deliming solvent...

Страница 31: ...er gasket part number 9004099215 Remove the drain valve 9 Install the long plastic male adapter insert fitting into the drain valve opening of heater after applying Teflon tape or paste to threads Tighten firmly by hand and use wrench or adjustable pliers to check for secure connection Do not over tighten to avoid damage to threads and fittings Prepare the Up N Down Transfer Kit The next step is t...

Страница 32: ...ng against diagram check for grounded broken or loose wires Check all wire ends to be sure that they are making good contact ELECTRICAL SERVICING LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION VERIFY PROPER OPERATION AFTER SERVICING Gas Control Valve Figure 30 shows the combination gas control valves used on these heaters If ...

Страница 33: ...e If rumbling persists call a qualified service agency Delime heater Ticking or metallic sounds Expansion and contraction normal Pounding water hammer Air chambers in piping have become waterlogged Thermal expansion tank damaged improperly charged or improperly sized Drain piping system and refill Heater must be off while this is being done Check thermal expansion tank charge pressure when the wat...

Страница 34: ...imit switch operation the water heater cannot be restarted unless the water temperature is reduced to approximately 120F 49C The high limit reset button on the front of the thermostat then needs to be depressed See Figure 2 for the location of the reset button start up conditions SMOKE ODOR It is not uncommon to experience a small amount of smoke and odor during the initial start up This is due to...

Страница 35: ... s operating thermostat should be set 5 degrees F higher than the Tank Temperature Control MULTI FLUE 1 UNIT WITH VERTICAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WIT...

Страница 36: ...mostat should be set 5 degrees F higher than the Tank Temperature Control MULTI FLUE 1 UNIT WITH HORIZONTAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES A...

Страница 37: ...s and the storage tank s MULTI FLUE 1 UNIT WITH MIXING VALVE TWO TEMPERATURE LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS TE...

Страница 38: ...ump between the water heater s and the storage tank s MULTI FLUE 2 UNITS LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS HOT WA...

Страница 39: ...stat should be set 5 degrees F higher than the Tank Temperature Control MULTI FLUE 2 UNITS WITH VERTICAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ...

Страница 40: ...stat should be set 5 degrees F higher than the Tank Temperature Control MULTI FLUE 2 UNITS WITH VERTICAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ...

Страница 41: ...at should be set 5 degrees F higher than the Tank Temperature Control MULTI FLUE 2 UNITS WITH HORIZONTAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ...

Страница 42: ...TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS BOOSTER WATER RETURN PRE HEATED WATER TO BOOSTER BOOSTER WATER TO FIXTURES HOT WATER T...

Страница 43: ...F VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS EXPANSION TANK BOOSTED WATER OUTLET TYPICAL BOOSTER HEATER PRE HEATER PRE HEATER MUST BE IDENTICAL HEATERS FINISHED FLOOR COLD WATER S...

Страница 44: ... LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS HOT WATER TO FIXTURES HOT WATER RETURN COLD WATER SUPPLY EXPANSION TANK PIPE T...

Страница 45: ... than the Tank Temperature Control MULTI FLUE 3 UNITS WITH VERTICAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENT...

Страница 46: ...er than the Tank Temperature Control MULTI FLUE 3 UNITS WITH HORIZONTAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIRE...

Страница 47: ...URE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS EXPANSION TANK COLD WATER SUPPLY HOT WATER TO FIXTURES FINISHED FLOOR HOT WATER RETURN PIPE T ...

Страница 48: ...Temperature Control MULTI FLUE 4 UNITS WITH VERTICAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS HOT WATER TO ...

Страница 49: ...k Temperature Control MULTI FLUE 4 UNITS WITH HORIZONTAL STORAGE TANK LEGEND TEMPERATURE PRESSURE RELIEF VALVE PRESSURE RELIEF VALVE CIRCULATING PUMP TANK TEMPERATURE CONTROL DRAIN FULL PORT BALL VALVE TEMPERATURE GAGE WATER FLOW SWITCH CHECK VALVE WARNING THIS DRAWING SHOWS SUGGESTED PIPING CONFIGURATION AND OTHER DEVICES CHECK WITH LOCAL CODES AND ORDINANCES FOR ADDITIONAL REQUIREMENTS HOT WATER...

Страница 50: ...rometric draft control assemblies combustion clearances and servicing must be added PRIOR TO START UP IMPORTANT Factory Start Up is required for activating warranty and assuring maximum operating performance Contact your local sales representatives or Authorized Start Up Agent to arrange a FREE Certified Start Up ...

Страница 51: ...G 81 140 HSG 200 62459 001 0 24 62459 001 0 209 GPG 81 199 HSG 200 62459 001 0 38 62459 001 0 257 GPG 81 270 HSG 400 62459 002 0 368 62459 002 0 302 GPG 81 370 HSG 400 62459 002 0 532 62459 002 0 386 MAIN BURNER ORIFICE CHART COMMERCIAL GAS Glass Lined Tank Type Water Heater REPLACEMENT PARTS LIST 51 ...

Страница 52: ...tric Draft Control w Tee Assy 9500007199 9500007199 9500007200 9500007200 Cleanout Assembly 4 Gasket 9004099215 9004099215 9004099215 9004099215 5 Pressure Plate 9005797205 9005797205 9005797205 9005797205 6 Screw Self Tapping Req d 9004100215 9004100215 9004100215 9004100215 7 Cover Cleanout Opening 181260 181260 181260 181260 8 Thermostat with ECO 9004529005 9004529005 9004529005 9004529005 9 Va...

Страница 53: ...notes 53 ...

Страница 54: ...notes 54 ...

Страница 55: ... acceptable method 4 SERVICE AND REPAIR EXPENSES Under the limited warranty the warrantor will provide only a replacement water heater or part thereof The owner is responsible for all other costs Such costs may include but are not limited to a Labor charges for service removal repair or reinstallation of the water heater or any component part b Shipping delivery handling and administrative charges...

Страница 56: ...Copyright 2013 State Industries Inc All rights reserved 500 Tennessee Waltz Parkway Ashland City TN 37015 Technical Support 800 365 8170 Parts 800 821 2017 www statewaterheaters com ...

Отзывы: