Actual
Input
Output (Gallons)
Storage
Rating
Ship.
Model Number
Capacity
BTU/Hr.
Firing
Recovery
Dimensions In Inches
Wt.
Motor HP
U.S.
Rate
w/Burner
120V 60 Hz 1
Gallons
GPH
80°F Rise 100°F Rise 140°F Rise
A
B
C
D
E
F
G
H
J
(lbs.)
TPD 150 140 ONEA
163
140,000
1
170
136
97
83
1
⁄
2
14
1
⁄
2
27
3
⁄
4
1
1
⁄
4
36
1
⁄
2
5
47
73
1292
TPD 150 199 ONEA
163
199,000
1.4
241
193
138
83
1
⁄
2
14
1
⁄
2
27
3
⁄
4
1
1
⁄
4
36
1
⁄
2
6
47
73
1292
1
⁄
7
HP - 4.4 Amp
TPD 150 255 ONEA
163
255,000
1.8
309
247
176
83
1
⁄
2
14
1
⁄
2
27
3
⁄
4
1
1
⁄
4
36
1
⁄
2
6
47
73
1292
TPD 150 270 ONEA
163
270,000
1.9
327
262
187
83
1
⁄
2
14
1
27
3
⁄
4
1
1
⁄
4
36
1
⁄
2
6
57
1
⁄
2
73
1397
TPD 150 400 ONEA
151
400,000
2.8
485
387
277
83
1
⁄
2
14
1
27
3
⁄
4
1
1
⁄
4
36
1
⁄
2
7
57
1
⁄
2
73
1397
TPD 150 540 ONEA
151
540,000
3.8
654
524
374
83
1
⁄
2
14
1
27
3
⁄
4
1
1
⁄
4
36
1
⁄
2
8
57
1
⁄
2
73
1505
TPD 150 720 ONEA
145
720,000
5.1
873
698
416
83
1
⁄
2
14
1
1
⁄
4
27
3
⁄
4
1
1
⁄
4
36
1
⁄
2
10
57
1
⁄
2
73
1510
1
⁄
4
HP - 4.6 Amp
TPD 200 300 ONEA
221
300,000
2.1
364
291
208
83
1
⁄
2
15
1
32
1
⁄
2
1
1
⁄
2
44
3
⁄
4
6
66
1
⁄
2
73
2098
TPD 200 600 ONEA
221
600,000
4.2
727
582
416
83
1
⁄
2
15
1
32
1
⁄
2
1
1
⁄
2
44
3
⁄
4
8
66
1
⁄
2
73
2098
TPD 200 800 ONEA
221
800,000
5.7
970
776
554
83
1
⁄
2
15
1
1
⁄
4
32
1
⁄
2
1
1
⁄
2
44
3
⁄
4
10
66
1
⁄
2
73
2103
TPD 200 1000 ONEA
201
1,000,000
7.1
1212
970
693
83
1
⁄
2
15
1
1
⁄
4
32
1
⁄
2
1
1
⁄
2
44
3
⁄
4
10
66
1
⁄
2
73
2103
1
⁄
3
HP - 5.5 Amp
TPD 200 1250 ONEA
201
1,250,000
8.9
1515
1212
866
83
1
⁄
2
15
1
1
⁄
4
32
1
⁄
2
1
1
⁄
2
44
3
⁄
4
12
66
1
⁄
2
73
2467
TPD 200 1500 ONEA
201
1,500,000
10.7
1818
1455
1039
83
1
⁄
2
15
1
1
⁄
2
32
1
⁄
2
1
1
⁄
2
44
3
⁄
4
12
81
1
⁄
2
73
2757
3
⁄
4
HP - 10.2 Amp
TPD 300 300 ONEA
300
300,000
2.1
364
291
208
91
1
⁄
2
14
1
26
1
⁄
2
1
1
⁄
2
44
3
⁄
4
6
66
1
⁄
2
83
2150
1
⁄
4
HP - 4.6 Amp
TPD 300 600 ONEA
300
600,000
4.2
727
582
416
91
1
⁄
2
14
1
26
1
⁄
2
1
1
⁄
2
44
3
⁄
4
8
66
1
⁄
2
83
2150
TPD 300 800 ONEA
300
800,000
5.7
970
776
554
91
1
⁄
2
14
1
1
⁄
4
26
1
⁄
2
1
1
⁄
2
44
3
⁄
4
10
66
1
⁄
2
83
2308
TPD 300 1000 ONEA
300
1,000,000
7.1
1212
970
693
91
1
⁄
2
14
1
1
⁄
4
26
1
⁄
2
1
1
⁄
2
44
3
⁄
4
10
66
1
⁄
2
83
2308
1
⁄
3
HP - 5.5 Amp
TPD 300 1250 ONEA
300
1,250,000
8.9
1515
1212
866
91
1
⁄
2
14
1
1
⁄
4
26
1
⁄
2
1
1
⁄
2
44
3
⁄
4
12
66
1
⁄
2
83
2584
TPD 300 1500 ONEA
300
1,500,000
10.7
1818
1455
1039
91
1
⁄
2
14
1
1
⁄
2
26
1
⁄
2
1
1
⁄
2
44
3
⁄
4
12
81
1
⁄
2
83
2774
3
⁄
4
HP - 10.2 Amp
TPD 400 600 ONEA
411
600,000
4.2
727
582
416
91
1
⁄
2
15
1
32
1
⁄
2
2
55
8
76
1
⁄
2
81
3207
1
⁄
4
HP - 4.6 Amp
TPD 400 800 ONEA
411
800,000
5.7
970
776
554
91
1
⁄
2
15
1
1
⁄
4
32
1
⁄
2
2
55
10
76
1
⁄
2
81
3212
TPD 400 1000 ONEA
411
1,000,000
7.1
1212
970
693
91
1
⁄
2
15
1
1
⁄
4
32
1
⁄
2
2
55
10
76
1
⁄
2
81
3212
1
⁄
3
HP - 5.5 Amp
TPD 400 1250 ONEA
411
1,250,000
8.9
1515
1212
866
91
1
⁄
2
15
1
1
⁄
4
32
1
⁄
2
2
55
12
76
1
⁄
2
81
3212
TPD 400 1500 ONEA
397
1,500,000
10.7
1816
1455
1039
91
1
⁄
2
15
1
1
⁄
2
32
1
⁄
2
2
55
12
91
1
⁄
2
81
3402
TPD 400 1750 ONEA
397
1,750,000
12.5
2121
1697
1212
91
1
⁄
2
15
2
32
1
⁄
2
2
55
14
91
1
⁄
2
81
3528
3
⁄
4
HP - 10.2 Amp
TPD 400 2000 ONEA
397
2,000,000
14.2
2424
1939
1385
99
1
⁄
2
15
2
32
1
⁄
2
2
55
14
91
1
⁄
2
89
3669
TPD 500 2250 ONEA
495
2,250,000
16
2727
2182
1558
110
15
2
32
1
⁄
2
2
55
16
91
1
⁄
2
100
4277
1 HP - 16 Amp
TPD 500 2500 ONEA
495
2,500,000
17.8
3030
2424
1732
110
15
2
32
1
⁄
2
2
55
16
91
1
⁄
2
100
4419
TPD 600 720 ONEA
594
720,000
5.1
873
698
499
119
15
1
1
⁄
4
32
1
⁄
2
2
55
10
76
1
⁄
2
109
3667
1
⁄
4
HP - 4.6 Amp
TPD 600 1000 ONEA
594
1,000,000
7.1
1212
970
693
119
15
1
1
⁄
4
32
1
⁄
2
2
55
10
76
1
⁄
2
109
3667
TPD 600 1250 ONEA
594
1,250,000
8.9
1515
1212
866
119
15
1
1
⁄
4
32
1
⁄
2
2
55
12
76
1
⁄
2
109
3667
1
⁄
3
HP - 5.5 Amp
TPD 600 1500 ONEA
594
1,500,000
10.7
1816
1455
1039
119
15
1
1
⁄
2
32
1
⁄
2
2
55
12
91
1
⁄
2
109
3837
TPD 600 1750 ONEA
594
1,750,000
12.5
2121
1697
1212
119
15
2
32
1
⁄
2
2
55
14
91
1
⁄
2
109
3837
3
⁄
4
HP - 10.2 Amp
TPD 600 2000 ONEA
594
2,000,000
14.3
2424
1939
1385
119
15
2
32
1
⁄
2
2
55
14
91
1
⁄
2
109
3837
TPD 600 2250 ONEA
575
2,250,000
16
2727
2182
1558
119
15
2
32
1
⁄
2
2
55
16
91
1
⁄
2
109
4477
1 HP - 16 Amp
TPD 600 2500 ONEA
575
2,500,000
17.8
3030
2424
1732
119
15
2
32
1
⁄
2
2
55
16
91
1
⁄
2
109
4619
TPD Power Dual Fuel Large Volume Commercial Water Heaters
COMMERCIAL
The Expert’s Choice
®
500 Lindahl Parkway, Ashland City, TN 37015 • www.statewaterheaters.com
SPECIFICATIONS
Certified Minimum Installation Clearances to Combustibles:
Front: 18 inches
Back: 0 inches
Sides: 0 inches
Top:
5 inches
A clearance of 24 inches should be maintained from
serviceable parts such as relief valve, power burner, drain
valve and anodes (anodes are located on side above cold
water inlet).
State Titan TPD models are Category I appliances
(Fan Assisted) and require a negative draft. These units
should only be commonly vented with other Category I
negative draft appliances per the latest addition of the
National Fuel Gas Code. An approved/listed Type “B” venting
material is recommended. A negative draft of -0.02˝ to -0.07
is required in the vent.
ASME