Instruction Manual

4

Installation 

Hardware Installation 

One of the Ethernet Extender Kits units should be considered a “Transmitting Unit”, 

while the other should be considered a “Receiver Unit.”

Transmitter Unit

1.  Place one of the units at the local location, this unit will act as the Transmitter Unit. 
2.  Connect the provided power adapter from an AC electrical outlet to the DC Power 

Input on the Transmitter Unit.  The “PWR” LED should light up solid.

3.  Set all four of the DIP switches to the downward (OFF) position. This places the 

Transmitter Unit in CO mode (Central Office Mode).

4.  Connect an RJ45 Ethernet cable to the RJ45 Port on the Transmitter Unit. 
5.  Connect the other end of the Ethernet cable into your Ethernet network device (eg: 

Ethernet switch, modem, etc). The “ETH” LED should light up solid.

6.  Connect an RJ11 phone cable into the RJ11 VDSL Port on the Transmitter Unit.
7.  Connect the opposite end of the RJ11 cable to the RJ11 VDSL Port on the Receiver 

Unit (or to your buildings RJ11 phone line infrastructure, depending on your setup).

Optional: 

Configure DIP switches 2 through 4 as necessary (see the “DIP Switch and 

Mode Settings” section). 

Receiver Unit

1.  Place the second unit at the remote location, this unit will act as the Receiver Unit. 
2.  Connect the provided power adapter from an AC electrical outlet to the DC Power  

  Input on the Receiver Unit.  The “PWR” LED should light up solid.
3.  Set the DIP switch setting #1 to the upward (ON) position, with the remaining 3  

  DIP switches set to the downward (OFF) position. This places the Receiver Unit in  

  CPE mode (Customer Premises Equipment Mode).
4.  If previously not completed, connect the RJ11 cable that was inserted into the RJ11  

  VDSL Port on the Transmitter Unit directly to the RJ11 VDSL Port on the Receiver  

  Unit (or from your buildings existing RJ11 analog telephone wiring, depending on  

  the setup from step 7 above.)
5.  If the Transmitter and Receiver Units are able to successfully communicate with  

  each other, the “DSL” LED should flash slow, then fast while establishing a      

  connection, and eventually light up solid. The “DSL” LED will continue to flash when  

  there is activity between the Transmitter and Receiver Unit.
6.  Connect your Ethernet network device (eg: Ethernet switch, modem, etc) to the  

  RJ45 Port on the Receiver Unit. The “ETH” LED should light up solid.

Optional: 

Configure DIP switches 2 through 4 as necessary (see the “DIP Switch and 

Mode Settings” section). 

Содержание 110VDSLEX2EU

Страница 1: ...om FR Guide de l utilisateur fr startech com ES Gu a del usuario es startech com IT Guida per l uso it startech com NL Gebruiksaanwijzing nl startech com PT Guia do usu rio pt startech com 110VDSLEXT2...

Страница 2: ...FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may...

Страница 3: ...troduction 1 Packaging Contents 1 System Requirements 1 Product Overview 2 Front View 2 Rear View 2 Side View 2 LED Indicators 3 Installation 4 Hardware Installation 4 DIP Switch and Mode Settings 5 T...

Страница 4: ...ansmitter 1x Ethernet VDSL2 Receiver 2x RJ45 Cables 8x Rubber Feet 2x Power Adapters 1x Instruction Manual 2x Wall mount screws and anchors System Requirements 10 100 Mbps Ethernet Network Available A...

Страница 5: ...DIP switch settings should be modified according to your specific needs based on direction of traffic By default all DIP Switch settings on each of the two units are set to the downward OFF position S...

Страница 6: ...D Indicators LED Green OFF ON Solid FLASHING PWR Power Power Off Power On NA ETH Ethernet No RJ45 Link Connection Connected Activity DSL VDSL No VDSL Link Connection Connected Slow Establishing Connec...

Страница 7: ...he DIP Switch and Mode Settings section Receiver Unit 1 Place the second unit at the remote location this unit will act as the Receiver Unit 2 Connect the provided power adapter from an AC electrical...

Страница 8: ...ates as intended with no problems errors or disruptions DIP switch settings 2 through 4 should be set to the same position on both your Transmitter and Receiver Units CO or CPE Mode Setting each unit...

Страница 9: ...t in either Symmetric or Asymmetric mode Set this DIP switch to the upward ON position for Symmetric mode with both downstream and upstream transmissions operating on the G 997 band plan or set to the...

Страница 10: ...returned for repair or replacement with equivalent products at our discretion The warranty covers parts and labor costs only StarTech com does not warrant its products from defects or damages arising...

Страница 11: ...ts and we quickly deliver them wherever they need to go Just talk to one of our tech advisors or visit our website You ll be connected to the products you need in no time Visit www startech com for co...

Отзывы: