background image

Wireless Indicator User Guide                                                                8                                                                                                     Ver 1.0 

 

The L. S. Starrett Company                                                                                                                                                3/7/2022 

Fig.8A

 

2.2 Setting the MIN/MAX/TIR Function 

The Min/Max/TIR (Total Indicator Reading or Run-out ) function measures the minimum and the maximum values 
of a surface (usually rotating) and then calculates the difference between them. (TIR), 
Note: This function is only available with the advanced indicators. 
 
1.  Select the units to be displayed. 
2.  Bring the indicator down to the part being measured, to a point that is around half the travel of the indicator. 
3.  Lock in the indicator at this height. 
 
Note: Care must be taken; to make sure the difference between the high and low measurements are not outside of  
the travel of the indicator at setup. Either your low measurement will be wrong or your high measurement might 
jam the spindle and damage your indicator. 

 

4.  Press the 

MIN/MAX/TIR 

button. The 

MIN

 icon will appear on the display. 

5.  Press the ZERO/ABS button to measure the part. 

6.  Move the part under the indicator to find the low spot.                                                                                                             

You will know because the value will not change. 

7.  Press the 

MIN/MAX/TIR 

button. The 

MAX

 icon will appear on the display. 

8.  Press the ZERO/ABS button to measure the part. 

9.  Move the part under the indicator to find the high spot.                                                                                                             

You will know because the value will not change. 

10. Press the MIN/MAX/TIR button. The 

TIR 

icon will appear on the display,                                                                                    

and the display will show the value of the TIR. If recording this value,                                                                                            

do not allow the spindle to move until you have written or sent the                        

value by pressing the Wireless button, Fig.8B. Press the MIN/MAX/TIR 

button to reset the indicator and remove the TIR icon from the display.  

11. Replace the part being measured, and repeat the sequence starting at step two above. 

MIN/            

MAX/TIR

 

Press 

1 - To start measuring in Min mode; 

Then 

2 - Next, to start measuring in Max mode; 

Then

 

3 - To display the TIR value; 

Press 

Press 

Table of Contents

 

ZERO    

ABS

 

ZERO    

ABS

 

MIN/            

MAX/TIR

 

MIN/            

MAX/TIR

 

4 - To send a reading, press the                       

wireless button Fig.8C 

Fig.8C

 

Fig.8B

 

Содержание W2900-1

Страница 1: ...Wireless Indicator User Guide 1 Ver 1 0 The L S Starrett Company 3 7 2022 The L S Starrett Company 121 Crescent Street Athol MA 01331 https www starrett com Wireless Electronic Indicator User Guide ...

Страница 2: ...Setting the MIN MAX TIR Function 8 2 3 Resolution Selection 9 2 4 Lock Mode 10 Section 3 Wireless Overview 3 0 Wireless Functions 11 3 1 Communicating with your Wireless Tool 12 3 1 1 Establishing First Communications 12 3 1 2 Moving Tools Between Gateways 12 3 1 2 1 Resetting a Wireless Tools Security Key 12 3 1 2 2 Moving to Another Gateway 1 12 Section 4 Rechargeable Battery 4 0 Rechargeable Ba...

Страница 3: ...ery symbol is showing Fig 1A then go to the Rechargeable Battery Care and Maintenance section on page 13 If there is no battery symbol visible then the battery is charged 2 Lightly clean the contact point 3 Fasten the indicator into the appropriate holding device 4 You can turn the indicator on by either pressing the ON OFF button or moving the spindle 5 If applicable pick the unit of measure inch...

Страница 4: ...nd release to turn on and Press and hold for 3 seconds to turn off 8 ZERO Press and release the ZERO button and the display will zero The spindle must not be moved until the Zero Sequence has elapsed See Zero Sequence on page 3 instruction 7 9 ABS Enables the ABS mode Press and hold for 2 seconds to activate the ABS mode Press and hold for 2 seconds to exit the ABS mode 10 PRESET Press the SHIFT S...

Страница 5: ...item indicates that the item is ready to be SET Changed Fig 5 5 Press the PRESET button to increment the digit value from 1 9 Press the SHIFT SET button to set the digit and move to next digit 6 To set a negative value press the PRESET button when the plus minus sign icon is flashing Fig 5 7 Repeat steps 4 and 5 until all the digits are SET 8 Use the SHIFT SET button to cycle through the digits ba...

Страница 6: ...TS button The MIN LIMIT MIN LIM Fig 6C icon will appear in the upper middle of the display Fig 6B C 4 Press the SHIFT SET button The LIMIT LIM icon will flash on off 5 Adjust the gauge using a reference surface to the desired minimum value 6 Press the SHIFT SET button to capture the minimum value The LIMIT LIM icon will stop flashing Continued on next page Fig 6A 1 To enter Min Limit mode Then Pre...

Страница 7: ...SET icon will remain on The MAX and MIN icons will stay off as long as the reading is within the set limits If the measurement is beyond the set limits the display will flash and the MIN or MAX LIMIT LIM icon will indicate the direction the limit has been exceeded To exit Press the LIMITS button Fig 7A The MAX LIMIT icon will appear Press Press The LIMIT icon will start flashing Adjust the gauge u...

Страница 8: ...isplay 5 Press the ZERO ABS button to measure the part 6 Move the part under the indicator to find the low spot You will know because the value will not change 7 Press the MIN MAX TIR button The MAX icon will appear on the display 8 Press the ZERO ABS button to measure the part 9 Move the part under the indicator to find the high spot You will know because the value will not change 10 Press the MI...

Страница 9: ...red If units are set to English then the resolution selection is displayed in inches If the units are set to metric then the resolution selection is displayed in mm Pressing the IN mm button will toggle the selection to the appropriate units This function is not available with the basic type indicators Round Off Condition English In Mode Metric mm Mode Round Off Enabled 000 00005 0000 001 Round Of...

Страница 10: ...s the following sequence of buttons 1 Press the SHIFT SET button then press and hold the LOCK button until the lock icon turns on 2 The Lock icon will turn on and stay on Fig 8C Once the lock mode has been activated the operator will not be able to change ABS Normal Mode Limits Units PRESET or MAX MIN TIR The operator will have access to the zero function and viewing of the MIN MAX TIR readings 3 ...

Страница 11: ...function If you continue to hold the Wireless button and then press the In mm button the tool will cycle through the functions one at a time When the desired function is displayed release the Wireless button to select the function Fig 11B Wireless Symbol Fig 9A Fig 9B 2 When the radio is active a short press on the radio button will transmit a reading The display will show either Sent or Held Fig ...

Страница 12: ...d show Green This means that they have exchanged keys and successfully established a secure link 3 1 2 Moving Tools Between Gateways If a Wireless Tool has established a secure link with a Gateway 1 and you want to move the tool to a new Gateway 2 the tool s security key needs to be reset 3 1 2 1 Resetting a Wireless Tools Security Key 1 First Turn off the Tool and then block it on the Gateway tab...

Страница 13: ... plugged in See Fig 13A E for information about the changes to the battery icon and what they mean If you wait to long to recharge the battery the tool will automatically shut down completely to conserve the remaining charge on the battery The battery must have a minimum charge to be recharged If the tool will not turn on with the on off button then you must charge the tool When the tool is plugge...

Страница 14: ...tery The tool will flash a sequence of information on the display see the examples below Fig s 14 17 This is normal for the indicator and a brief description of the screens is shown below 2 At the end of the sequence you will see CAL on the display See 4 2 Calibrate below for instructions Fig 14 Full Lamp shows all characters Fig 16 Indicator Version Fig 15 Indicator Number Fig 17 Firmware Version...

Отзывы: