Machine Positioning
•
Unpack machine, check for damage and complete delivery.
•
Install machine on sound waterproof self-draining floor and use adjustable feet to level.
NOTE: Failure to level the machine correctly may result in leaking during the cycle,
overflowing from the door sill, poor hygiene through the wash tank not being able to
drain correctly, and/or visibly uneven door.
•
Allow room for detergent to one side of machine or in adjacent cupboard. 20 litre container
requires approximately 450H x 250W x 350D, but smaller containers are available from many
suppliers.
Ventilation
•
The CDe includes an integrated heat recovery unit in the top of the machine which captures
and removes sufficient steam to enable it to be installed without a kitchen exhaust hood,
subject to the area having minimum background ventilation of 1.1m2 free area opening
and/or 350L/s mechanical ventilation or air change.
NOTE: The heat recovery system also requires the vents on the hood of the machine to
be kept well clear of obstructions – do not to use the top of the machine for storage,
and do not close the doors to the washroom if this is required as part of the minimum
background ventilation. Staff must also be trained around the correct fitting of curtains.
Inlet Water Operation - Cold
Incoming water should be within the following standard requirements:
•
Recommended temperature: 20°C.
NOTE: Inlet water temperatures above 25°C may necessitate a recalibration of other
settings e.g. wash and pre-wash temperatures, and the airflow of a dryer if fitted.
•
Connection: 20 mm (3/4” BSP) male.
NOTE: Flush supply line before connection. Poor quality supply or excessive water
hardness may affect performance or damage machine – filtration and/or softening is
recommended.
•
Flow rate: minimum 20 litres per minute.
•
Water consumption: 2 litres per minute.
•
Pressure: between 200 and 350 kPa.
NOTE: This machine is not equipped with a rinse booster pump as standard and relies on
incoming water pressure to drive the rinse cycle.
NOTE: Above this range fit pressure limiter. Below this range fit a rinse booster pump. Do
not use small diameter plastic supply lines
•
Backflow prevention: Atmospheric Vacuum Breaker (AVB) fitted standard.
Inlet Water Fill - Hot
Incoming water should be within the following standard requirements:
•
Recommended temperature: 65°C.
NOTE: Excessively high temperatures may damage the solenoid which can result in
flooding should this component fail. High temperature solenoids are available and can be
retrofitted if necessary.
•
Connection: 20 mm (3/4” BSP) male.
NOTE: Flush supply line before connection. Poor quality supply or excessive water
hardness may affect performance or damage machine – filtration and/or softening is
recommended.
•
Flow rate: minimum 20 litres per minute
•
Pressure: between 200 and 350 kPa.
NOTE: Above this range fit and approved pressure limiter. Do not use small diameter
plastic supply lines.
•
Backflow prevention: Atmospheric Vacuum Breaker (AVB) fitted standard.
2/19/2020
Starline CDe240 Operator Manual
6