Handbook for the SXV-M25C     Issue 1 June 2004 

 

27

calculations. The training will also determine the angle at which the guide 
camera is oriented with respect to the RA and Dec axes. If you do not wish to 
train the system at this time, the default values of 6 pixels per second will 
serve as a starting point. 

9)

 

Now press ‘Go to main camera’ and the guider control panel will be replaced 
by the camera control panel. Set the required exposure time for the image (say 
5 minutes) and press the ‘Autoguide next image’ button. The autoguider 
window will reappear and, after a few seconds, you should see error values 
appearing in the text windows at the top. The guide star will be fairly close to 
the green cross, although not necessarily accurately centred, and you should 
see the power/ guide LED on the rear of the camera brighten and change 
colour with each correction. 

10)

 

If the star begins to drift away from the cross, despite the corrections being 
made, the chances are that the N/S and/or E/W directions are set wrongly. 
Judge which axis is incorrectly set by observing the direction of the drift and 
then stop the exposure by pressing ‘Esc’. Open the guider control panel and 
check the appropriate swap box(es). After this operation, you will probably 
need to find the guide star again by taking a guider image and reselecting the 
star, as before. Now return to the main camera menu and try the ‘Autoguide 
next image’ button again. 

11)

 

Once guiding is taking place without problems, the main exposure can be 

allowed to finish and, if all is well, you should see an image with tiny circular 
stars.  

 
If the stars are not circular, you may need to alter the guiding parameters, or 
investigate the rigidity and drive performance of your mount. A lot of information 
can be deduced by watching the behaviour of the guide star in the guider frame. If 
it is continually moving between two locations, either side of the green cross, then 
the RA or Dec pixels per second value is set too low. The higher these values are 
set, the gentler the guiding becomes. Too low a value will cause an over-
aggressive correction to be made and result in oscillation of the star position 
between two points. 
 
Another source of guiding errors can be a too accurately balanced telescope 
mount! Good balance can result in the telescope mount ‘bouncing’ between the 
gear teeth as corrections are made. A simple fix is to add a weight of about 0.5kg 
(1 pound) on the eastern end of the declination axis, so that there is always some 
pressure acting against the gear teeth. 
 
Getting a good result from an autoguider will often entail a lot of detective work 
to eliminate the sources of gear error, telescope flexure, mirror shift etc., but the 
final result is well worth the effort! 

 
********************************************************************* 
 

Using the built-in serial ports 

 

The SXV-M25C incorporates two fast serial ports for use with external accessories. 
The ports are available on 5 pins of the 18 way connector that is provided for the 
autoguider and may be accessed by plugging in a ‘serial port divider box’. The divider 

Содержание SXV-M25C

Страница 1: ...optional add on autoguider output and integrated dual serial ports for filter wheel and telescope control The SXV M25C uses a Sony ICX413AQ a very large SuperHAD interline CCD with 3040 x 2016 x 7 8u...

Страница 2: ...to the mount 7 A USB2 camera cable 8 An adaptor for 2 drawtubes and M42 Pentax thread lenses 9 A disk with the SXV M25C control software 10 This manual Optional extra items include 1 A serial port sp...

Страница 3: ...ot see the directories C Windows Inf and Windows System32 Drivers this will be due to the setup of your Windows Explorer software In this case go to the Tools menu followed by Folder Options and selec...

Страница 4: ...elled BlockIOClass and clicking on the sign will reveal it to be a Starlight Xpress USB 2 0 SXV M25C camera driver or similar If this device is faulty try clicking on it and selecting properties and t...

Страница 5: ...r the SXV M25C Issue 1 June 2004 5 The camera rear panel Connect up the power supply and switch it on You can start the SXV_M25C software by double clicking on the icon and you should see the main men...

Страница 6: ...defaults from the File menu and then saving the defaults window by pressing the Save changes button Once the camera control panel is seen you are all set to take your first images Recording your first...

Страница 7: ...focus problems and keep the light level reasonable for daytime testing The pin hole needs no such adjustments and will work immediately although somewhat fuzzily Point the camera lens or pinhole towa...

Страница 8: ...d the image using the sliders at the right and bottom edges or select Bin high res display as found in the View menu This reduces the displayed image to half size and most of it will now be visible th...

Страница 9: ...er This will re load the USB software and may fix the problem after restarting the SXV_M25C program Otherwise check the device driver status as previously described and re install any drivers which ap...

Страница 10: ...our to a neutral grey 3 Colour Smoothing Filter Applies a low pass filter to the colour data to smooth out colour noise 4 Apply Anti Alias Runs a special filter over the colour data to remove coloured...

Страница 11: ...h the processing software and this can vary If the colour is badly wrong try opening the Set program defaults dialog box and altering the Pixel and Line offsets Reload the raw file and try synthesis a...

Страница 12: ...peak until the background is nicely balanced In some cases the histograms may all start a long way above zero usually in astro images with a lot of light pollution In this case slide the start point...

Страница 13: ...rpness and this can be very effective on daylight images Too much high pass filtering results in dark borders around well defined features and will increase the noise in an image to unacceptable level...

Страница 14: ...25C and a 2 arc seconds per pixel resolution we get F 0 0074 205920 2 761mm This is a very rough guide and so the 500mm FSQ is well suited as are most other short focus refractors Achieving a good foc...

Страница 15: ...ction spikes around stars which merge at the setting of exact focus The 12 16 bit slider control allows you to adjust the contrast of the focus frame for best visibility of the star image It defaults...

Страница 16: ...minutes as above then don t bother with a dark frame just kill any hot pixels with your processing software In SXV M25C the Median filter can do this but other software e g Maxim DL will provide a hot...

Страница 17: ...ture onto the CCD chip where they appear as shadow do nuts Most optical systems show some vignetting at the edges of the field especially when focal reducers are used This causes a brighter centre to...

Страница 18: ...nge available leading to un correctable colour errors Keep a copy of the original file just in case Set the colour synthesiser to apply the anti alias filter and then run it 3 The resulting image will...

Страница 19: ...strongly increased and dark rings will appear around the stars but a Median filter can remove odd speckles hot pixels and a mild Unsharp Mask Radius 3 Power 1 will sharpen without too much increase i...

Страница 20: ...ent the creation of a proper colour image Summing can be done in the Merge menu and involves loading the first processed image selecting a reference point a star then loading the second image and find...

Страница 21: ...tube You can even try using a light pollution filter to bring out nebulae reduce light pollution and sharpen the star images The Hutech IDAS types are particularly effective with a colour camera Adju...

Страница 22: ...he definition of about 95 of your images and so I recommend setting the camera to run in Autosave mode This will automatically take a sequence of images and save them with sequential file names in you...

Страница 23: ...a more natural look to the image as too large a radius and power tends to outline edges with dark or bright borders As a finishing touch the application of a Median filter or a Weighted Mean Low Pass...

Страница 24: ...routine will learn the angle of the head and compensate for it but it is easier to understand the motion of the guide star if the guider frame is aligned with the RA and Dec axes Now connect the head...

Страница 25: ...5 The autoguider installed on a 80mm refractor guide scope in the author s garden To use the autoguider please proceed as follows 1 Having started the SXV M25C software open the autoguider control pan...

Страница 26: ...guiding rate is selected on your mount typically 2x sidereal Adjust this if necessary 5 Move the mount until the required object for imaging is properly framed in the main CCD image leave the guider m...

Страница 27: ...ge button again 11 Once guiding is taking place without problems the main exposure can be allowed to finish and if all is well you should see an image with tiny circular stars If the stars are not cir...

Страница 28: ...hort exposure time as the read out noise will become dominant About 30 seconds is a reasonable minimum Now go to the Multiple Exposure Options and select a number of exposures to take You can also sel...

Страница 29: ...with the standard autoguider input of most telescope mounts It provides 4 active low opto isolator outputs and a common return line capable of sinking a minimum of 5mA per output This socket may be u...

Страница 30: ...ohol A very suitable cloth is the Micro Fibre type marketed by PENTAX etc and suitable alcohol is available from Tandy Radio Shack etc as tape head cleaning fluid A bright light and a strong watchmake...

Страница 31: ...periods between uses The cold CCD will collect ice by slow diffusion through any small leaks and this will become corrosive water on the cooler and CCD pins when the power is removed If substantial am...

Страница 32: ...tion to any statutory Consumer Rights of Purchasers CONDITIONS OF GUARANTEE 1 The equipment shall only be used for normal purposes described in the standard operating instructions and within the relev...

Страница 33: ...Handbook for the SXV M25C Issue 1 June 2004 33 Web site http www starlight xpress co uk...

Отзывы: