2.
Installing the Reverse Fit device and deployment
1.
If your Reverse Fit device has been retrofitted, install counterparts on both
sides of the bucket (attachment with hexagonal screws: 6 pcs of DIN933 8.8
M16x60 bolts + nyloc nuts for each side). Figure 1 displays the placement of
the counterpart.
Figure 1. Counterpart placement
2.
The counterparts do not have to be removed from the bucket sweeper even if
the Reverse Fit device is not used.
3.
Grip the Reverse Fit device by the fittings with a base machine and grip the
bucket counterparts with the shaft grip slots such that the joint pin of the
counterpart touches the bottom of the slot (Figure 2).
4.
Lock the Reverse Fit device onto the counterpart with the mechanical locking
system on both sides of the bucket (Figure 3). Do not forget to use the cotter
to lock the attachment. Note! Be careful not to leave your fingers between
the parts when using the locking system.
5.
Remember to attach the hydraulic hoses.
6.
For removal, complete the process in reverse. Note! When removing the
locked shafts from the counterparts, make sure that the shaft does not lift or
press the bucket! The mechanical lock system must not be removed if the
bucket is pressed, as this may cause the shaft to fall abruptly!