GENERAL INSTALLATION DATA (continued)

PLACING RADIANTS - RCB SERIES

After the unit is unpacked and installed, place  radiant above each burner. Install each radiant 
on 2 slots of the rear wall and on  pin of the front wall of the liner weld assembly. Refer to the 
exploded view in this manual for orientation of the radiants.  

PLACING LAVA ROCKS- CB SERIES

Open the lava rock bags and place rock evenly on the lower internal grates - not the top cooking 
grates.  Spread the lava rock evenly on the grates approximately  layer thick.  Do not cover 
the grates with more than two layers of lava rock.  Do not put more than 5 pounds of rock per 
burner section.  

GAS PIPING

Gas piping shall be of such size and so installed as to provide a supply of gas sufficient to meet 

the full gas input of the appliance. If the appliance is to be connected to existing piping, it shall 
be checked to determine if it has adequate capacity. Joint compound shall be used sparingly and 
only on the male threads of the pipe joints. Such compounds shall be resistant to the action of 
L.P. gases. WARNING: Any loose dirt or metal particles which are allowed to enter the gas lines 
on this appliance will damage the valve and affect its operation. When installing this appliance, 

all pipe and fittings must be free from all internal loose dirt.

GAS PRESSURE REGULATOR

A convertible pressure regulator is provided with each charbroiler. It should be connected to the 
inlet pipe at the rear of the unit. The gas supply is then connected to it. The supply pressure to 
the regulator is not to exceed /2 PSIG.  It is shipped set for 5" water column manifold pressure 
for use with natural gas. 

MANUAL SHUT OFF VALVE

A manual shut off valve should be installed upstream from the manifold and within six feet of 
the charbroiler.

CONNECTING GAS SUPPLY LINE

The gas inlet of the charbroiler is sealed at the factory to prevent entry of dirt. Do not remove 
this seal until the actual connection is made to the gas supply line. 

PROPANE GAS - CONVERSION

This charbroiler is equipped with fixed orifice hoods and is shipped from the factory for use with 

natural gas. To convert to propane gas, install the burner orifice hoods, located in the water 

pan, as follows:

.  Remove grates, radiants and burners.

2.  Remove the burner orifice hoods and install the orifice hoods supplied.

3.  Replace the burners, radiants, and grates.
4.  Set manifold pressure to (0) inch water column.  A /8" pipe plug on the burner manifold 

can be removed for attaching a pressure gauge.  Remove the slotted, or hex-threaded plug 
from the pressure regulator.  Invert the plug and re-install.  The letters "LP" should now be 
visible on the plug.  The regulator is now set for 0" (25.4 cm) water column. Attach the 
conversion label, supplied with the unit, close to the nameplate.

CHECKING FOR GAS LEAKS

Check entire piping system for leaks. Soap and water solution or other material acceptable for 
the purpose, shall be used in locating gas leakage. 

 

 

CAUTION

Matches, candle flame or other sources of ignition shall not be used for locating 

gas leaks. 

CAUTION

Содержание Ultra-Max 8024CB

Страница 1: ...ge injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment FOR YOUR SAFETY Do not store or use gasoline or other flammable...

Страница 2: ...ate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks i...

Страница 3: ...l 8 Controls 160 000 BTUH Total 20 000 BTUH Nat LP per burner 1 209 sq in 7 800 sq cm Grid Area Approximate Weight Installed 314 Lbs 142 4 kg shipping 398 Lbs 180 5 kg Dimensions 48 Width 30 5 8 Depth...

Страница 4: ...ANSI Z21 69 or CAN CGA 6 16 and a quick disconnect device complyingwitheitherANSIZ21 41orCAN1 6 9 Itmustalsobeinstalledwithrestrainingmeansto guard against transmission of strain to the connector as...

Страница 5: ...prior to installing the caster Cut leg should measure 19 tube length not overall length Casters add about 6 1 4 of height to the unit Be sure to use approved strain relief means for protecting gas li...

Страница 6: ...the inlet pipe at the rear of the unit The gas supply is then connected to it The supply pressure to the regulator is not to exceed 1 2 PSIG It is shipped set for 5 water column manifold pressure for...

Страница 7: ...s prevent flare ups and catches grease BURNER OPERATION Each burner is controlled by an individual high low on off valve Avariety of broiling temperatures may be obtained by turning the burner valve k...

Страница 8: ...RBROILER TO COOL SHUTTING DOWN INSTRUCTIONS Turn the burner valve knobs to the off position to turn burners off and close manual valve gas shutoff CLEANING Clean regularly Remove grate section to sink...

Страница 9: ...ve cleaners abrasive pads product identifiers and point of sale attachments or any other non food object tha comes in continuous contact with the roller coating This warranty does not apply to the non...

Страница 10: ...7 16 14 17 18 8B 8A STAR MANUFACTURING INTERNATIONAL INC CERTAIN INSTANCES MAY NOT BE AVAILABLE ILLUSTRATIVE PURPOSES ONLY AND IN SOME ITEMS ARE INCLUDED FOR MODEL SK1865 REV C 5 9 06 8124RCB 8024CB...

Страница 11: ...12 HOOD BURNER ORIFICE 47 NAT ALL 2J Y7250 4 6 8 10 12 HOOD BURNER ORIFICE 55 LP ALL 12 2V Z4736 4 6 8 10 12 PILOT TUBE ALL 13 2V 6671 4 6 8 10 12 PILOT VALVE ALL 14 2F Z4692 4 6 8 10 12 TOP GRATE 5...

Страница 12: ......

Страница 13: ......

Страница 14: ...IONS POUR TEINDRE LE BARBECUE Pour teindre les br leurs tourner les boutons des br leurs sur la position de fermeture NETTOYAGE Nettoyer le barbecue r guli rement Enlever la section du grille et la la...

Страница 15: ...de pr venir les flamb es et attrape la graisse L OP RATION DU BR LEUR Chaque br leur est contr l par un individu haut bas sur ferm valve La vari t des temp ratures de cuisson sur le gril peut tre obte...

Страница 16: ...ble Il doit tre raccord au tuyau d admission l arri re de l appareil L alimentation de gaz y est raccord e La pression d approvisionnement au r gulateur ne doit pas exc der 1 2 PSIG Pour l utilisation...

Страница 17: ...rieur de tube avant d installer la roulette La jambe de coupe devrait mesurer 19 longueur de tube longueur hors tout Les roulettes ajoutent environ 6 1 4 de taille l unit Soyez s r d utiliser des moye...

Страница 18: ...AN CGA 6 16 et un dispositif rapide tant conforme la norme ANSI Z21 41 ou au CAN1 6 9 Il doit galement tre install avec des moyens retenants de garder contre la transmission de la contrainte au connec...

Страница 19: ...uits sans communication pr alable De telles r visions ne ont pas droit l acheteur aux changements aux am liorations aux additions ou aux remplacements correspondants pour l quipement pr c demment ache...

Страница 20: ...l sera install selon des r glements actuels et utilis seulement dans l espace bien a r R f rez vous aux instructions avant d installer et utiliser cet appareil POUR VOTRE S RET N enregistrez pas ou n...

Отзывы: