background image

OPERATION

START-UP

When the unit is first turned on it will begin the PRE-HEAT mode.  The current hold temperature will 

be displayed for 3 seconds, then “PHT” (PREHEAT) will flash along with the “HEAT ON” lamp until 

the unit has reached its preset hold temperature.  When this has been reached, the audible alarm will 

beep 3 times, the “HEAT ON” lamp will stop flashing and the display will read “RDY”.

COOKING

Load the unit with the product, (thawed not frozen) Press the “COOK” button to begin.  The “COOK” 

light will remain on and the Temp light will be on as the unit call for heat.  “COOK” will display for 3 

seconds, and then the internal cook timer will begin counting down.
Close the drawer.
When the timer reaches 00:00, the audible alarm will beep 3 times.  
Then you have two options:

1.  Remove  the  product  immediately  from  the  Thermal  Vection  and  place  in  on  your  preheated 

roller grill for display, then press the “RESET” button.  This will take the temperature back to the  

PRE-HEAT mode temperature, until you are ready to cook again.

2.  Leave the product in the Thermal Vection until you are ready to serve, the unit will maintain the 

HOLD temperature and an internal timer will begin to count down, after 3 hours an audible alarm 

will sound for 3 seconds and the display will flash “DoNE” until the RESET button is pressed.  At 

this time the remaining product left in the unit has expired and needs to be discarded.

READING TEMPERATURE

At any point the operator can view the actual temperature by pressing the “TEMP” button.  The 

reading will be displayed in the temperature mode (°F or °C) which is programmed.

PROGRAMMING THE TEMPERATURE MODE

The temperature mode can be changed from °F to °C or °C to °F by pressing and holding the “TEMP” 

button while turning on the main power switch.  The set-point temperature that is displayed will be in 

the changed temperature mode.

PROGRAMMING HOLD / PREHEAT TEMPERATURE MODE ( F / C)

The HOLD / PREHEAT temperature and hold time can be programmed using the following steps.  

The default HOLD temp and TIME are 140°F (60°C) for 3 hours.

1.  Simultaneously press and hold the “TEMP” and “HOLD” buttons for approx 3 seconds.
2.  The display will show “----“
3.  Release the buttons.
4.  Enter the 4 digit security code. (4,3,2,1)
5.  Once completed, the current hold / preheat temperature will be displayed.
6.  To increase or decrease the temperature use the “UP” or “DOWN” arrows.
7.  Press the “TEMP” button to save the change.
8.  The current time duration for the HOLD mode is now displayed.
9.  Use the “UP” or “DOWN” arrows to increase or decrease the HOLD time. 
10. Press the “TEMP” button to save the new HOLD time.
11.  Press the “TEMP” button again to exit the programming mode.

Содержание TVD Thermal Vection Series

Страница 1: ...THERMAL VECTION Heat and Hold Drawer MODEL TVD30 TVD50 Installation and Operation Instructions 2M Z14279 Rev A 7 16 13 IL2263...

Страница 2: ...ate we are not responsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks i...

Страница 3: ...n food service locations VOLTAGE The thermal vection is equipped for use on the voltage specified on the nameplate DO NOT CONNECT TO ANY OTHER TYPE OF CURRENT OR THE MACHINE WILL BE SERIOUSLY DAMAGED...

Страница 4: ...l sound for 3 seconds and the display will flash DoNE until the RESET button is pressed At this time the remaining product left in the unit has expired and needs to be discarded READING TEMPERATURE At...

Страница 5: ...EMP button to save the change 8 The current time duration for the COOK mode is now displayed 9 Use the UP or DOWN arrows to increase or decrease the COOK time 10 Press the TEMP button to save the new...

Страница 6: ...ha comes in continuous contact with the roller coating This warranty does not apply to the non stick properties of such materials This warranty does not apply to Special Products but to regular catalo...

Страница 7: ...TS IS PERMITTED E11 E12 E1 E2 E3 E4 E7 E6 E5 1 5 15P PLUG BLACK WHITE GREEN 2 3 4 4 10 4 8 9 SENSOR FAN RELAY TERMINAL TRANSFORMER SWITCH CONTROL BLOCK BOARD PROBE 5 6 7 11 11 12 12 HEATING ELEMENT 1...

Страница 8: ...STAR MANUFACTURING INTERNATIONAL INC Rev 5 25 11 SK2514 MODEL TVD THERMAL VECTOR MAIN BREAKDOWN See Detail B See Detail A 1 2 3 7 8 6 4 5 9 10 5 11 12 13 14 18 18 17 16 15 16 15...

Страница 9: ...TRANSFORMER 115 10V 6VA ALL 5 2C Z2594 10 NUT 6 32 HEX W STL NP ALL 6 2E 05 07 0352 1 RELAY 30 AMP ALL 7 2E Z2894 1 TERMINAL BLOCK 304 ALL 8 2K 76118 1 STRAIN RELIEF STR HEYCO 1 ALL 9 2A Z11501 4 FOO...

Страница 10: ...10 STAR MANUFACTURING INTERNATIONAL INC Rev 5 25 11 SK2515 MODEL TVD THERMAL VECTOR DETAIL BREAKDOWN Detail A Detail B 1 2 3 14 15 16 17 18 3 19 23 7 20 21 22 7 7 12 13 9 11 10 8 4 5 6...

Страница 11: ...OR MOUNTING TVD30 120 A4 Z14412 TVD50 120 9 2R Z14035 1 FAN BLADE 3 CCW 90 DEG ALL 10 2C 1811 2 WASHER 1 4 BURR STL NP ALL 2C 08 07 0262 1 WASHER SS 1 4 INT LOCK 11 2C Z14640 1 NUT M6X1 LH THREADS SS...

Страница 12: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6303 www star mfg com...

Отзывы: