3
CLEARANCE
Clearances for combustible and non-combustible
materials a vertical distance of not less than 48"
shall be provided between the top of the
appliance and a 6" clearance from the side and
back. Adequate clearance should also be
provided for proper operation and servicing.
PRESSURE REGULATOR
A convertible pressure regulator set at 6" water
column for use on natural gas is furnished. Attach
the regulator to the supply pipe, located at the
back of the unit, make sure gas flow arrow on
regulator is pointing towards manifold. The gas
supply is then connected to the regulator. A 1/8"
tap is furnished on the manifold for checking
pressure. The manifold is accessible by removing
the front panel.
MANUAL SHUT OFF VALVE
A manual shut off valve should be installed
upstream from the union and within six feet of
the appliance
CONNECTING GAS SUPPLY LINE
The gas inlet on this appliance is sealed at the
factory to prevent entry of dirt. Do not remove
this seal until the actual connection is made to the
gas supply line.
CHECKING FOR GAS LEAKS
Soap and water solution or other material
acceptable for the purpose, shall be used in
locating gas leakage. Matches, candle flame or
other sources of ignition shall not be used for this
purpose.
AIR SUPPLY
Provisions for adequate air supply must be
furnished.
AIR INTAKES IN BOTTOM
Make certain the air intake openings in the
bottom of the appliance are not obstructed. They
are essential for proper combustion and
operation of the appliance.
EXHAUST CANOPY
It is essential that facilities be provided to carry
off fumes and gases.
GAS INPUT OF HOT PLATE
For Natural Gas:
Model 602-24,000 BTU/HR or 12,000 BTU/HR
for each burner. Regulator output pressure set at
6" water column.
Model 602H-40,000 BTU/HR or 20,000 BTU/HR
for each burner. Regulator output pressure set at
6" water column.
For Propane Gas:
Model 602-24,000 BTU/HR or 12,000 BTU/HR
for each burner. Regulator output pressure set at
10" water column.
Model 602H-40,000 BTU/HR or 20,000 BTU/HR
for each burner. Regulator output pressure set at
10" water column.
Note: The appliance is equipped with natural
gas orifice hoods. A separate set of hoods
(black color) are provided for use on propane
gas. The propane hoods are located on the
front panel.
LIGHTING INSTRUCTIONS
The appliance is equipped with a standing pilot,
which is located in the center of the appliance
between the front and rear burners, and should
be lighted immediately after the gas is turned on.
1. Turn control knobs to "OFF" position.
2. Remove the two top grates and light pilot with
a lighted taper through the hold provided in
the center of the top tray.
3. The pilot valve is located on the manifold
located at the front of the unit. Turn the
adjustment screw on the front of the pilot
valve, which is accessible through an opening
on the front panel. The pilot should be
adjusted to as short a flame as possible and still
have good ignition to the burners.
4. If the pilot is out turn off gas, wait 5 minutes
and repeat steps (1) through (3).