2.5. Memory Switch Settings
1. Change the Memory switch by this operation. (Refer to Table 1).
MODE button : changing Printer MODE status
FEED button : changing OPTION status.
2. [Example] The defaults of the printer are :
Bluetooth/57600 bps/8 Data bit/No Parity/1 Stop bit/Density Medium
If a user wants to change the defaults with
RS-232C/9600 bps/7 Data bit/Even Parity/2 Stop bit/Density High
u
After pressing the MODE button simultaneously, if the ERROR lamp 5 turn
signals MODE button is converted with MODE functions
g
You will see present COMMUNICATION mode in the LCD.
g
Press the MODE button one time.
(The interface mode has set to RS-232C mode.)
Bluetooth
g
RS-232C
u
Press FEED button one time.
g
You will see present BAUD RATE mode in the LCD.
Communication Port
g
Baud Rate
g
Press the MODE Button twice.
(The baud rate has set to 9600 bps)
57600 bps
g
115200 bps
g
9600 bps
u
Press FEED button one time.
g
You will see present DATA BIT mode in the LCD.
Baud Rate
g
Data Bit
g
Press the MODE button one time.
(The data bit has set to 7 data bit.)
8 Data Bit
g
7 Data Bit
u
Press FEED button one time.
g
You will see present PARITY BIT mode in the LCD.
Data Bit
g
Parity Bit
g
Press the MODE button twice.
(The parity bit has set to even parity bit.)
No Parity
g
Even Parity