3.4.  Depth functions (optional) 

To change between Log and Depth information press 

MODE

. This 

function will display depth in metres, feet or fathoms. To change unit 
see 4.2.6. A depth sounder measures the time it takes for a sound 
pulse transmitted from the transducer, to bounce on the bottom and 
be received by the transducer again. The strength of the sound 
pulse decreases with the depth and is also affected  
by temperature and pollution in the water. A soft bottom with a lot of 
vegetation will also decrease the strength of the echo, which can result 
in poor reception by the receiver. If no echo is registrated the depth 
reading will be three dashes i.e. no echo. 

3.4.1. Boat 

speed 

To view boat speed press 

UP

 or 

DOWN

 until the text BSP is dis-

played. The unit (Knots or Miles/h) is selectable in calibration, see 
4.2.4. 

3.4.2. Shallow 

alarm 

To get to the shallow alarm function, press 

UP

 or 

DOWN

 until the 

text  
SHALLOW is displayed. To change the alarm value, unlock with 

KEY

increase/decrease the value with 

UP

/

DOWN

, move to the next figure 

with 

MODE

 button and lock the value again with 

KEY

3.4.3. Deep 

alarm 

To get to the deep alarm function press 

UP

 or 

DOWN

 until the text  

DEEP is displayed. To change the alarm value, unlock with 

KEY

,  

increase/decrease the value with 

UP

/

DOWN

, move to next figure  

with 

MODE

 button and lock the value  

again with 

KEY

. The alarm is activated. 

3.4.4. 

Silencing an alarm 

If a shallow alarm limit is reached the instrument will display depth on 
the top row  
and the alarm limit flashing on the bottom row. To silence the alarm 
press any  
button or steer the boat to deeper water. The alarm will be automatically 
activated  
again if the boat is taken to deeper water ( 2 m more than the limit).  

3.4.5. 

Activate / Deactivate an alarm 

To activate / deactivate an alarm, go to the alarm function an press 

UP

  and  

DOWN

 together. If an alarm is active the present alarm value is dis-

played  
together with the text SHA or DEP. If the alarm is deactivated the text 
SHALLOW  
or DEEP is displayed instead. The alarm value is stored in the memory 
even if  
the alarm is deactivated. 

Содержание Sea Data

Страница 1: ...Installation and User Manual Sea Data English ...

Страница 2: ...Sea Data English 1 ...

Страница 3: ...English Sea Data 2 This manual is written for Silva Star Sea Data Edition May 2004 ...

Страница 4: ... Illumination 8 3 4 Depth functions optional 9 3 4 1 Boat speed 9 3 4 2 Shallow alarm 9 3 4 3 Deep alarm 9 3 4 4 Silencing an alarm 9 3 4 5 Activate Deactivate an alarm 9 4 Calibration 10 4 1 Enter and exit calibration 10 4 2 Calibration groups 10 4 2 1 C10 Return RET 10 4 2 2 C11 Damping SEA MID 10 4 2 3 C12 Instrument type Type LOG 10 4 2 4 C13 Unit for speed Unit KTS 10 4 2 5 C14 Speed calibrat...

Страница 5: ...tance 0 19999 99 Nm non resetable Stored in permanent memory Depth 0 5 150 m Deep alarm Adjustable Shallow alarm Adjustable 1 1 Part specifications Star SEA Data is delivered with all mounting material Make sure all these parts are in the pack age QTY ITEM QTY ITEM 1 Instruction for use 1 Drill template 1 Warranty card 4 Mounting screws 1 Instrument SEA Data 4 Rubber plugs 1 Instrument cover 1 Red...

Страница 6: ...drill through the instruments four mounting holes as the gasket may be dam aged and thus cause leakage The warranty is not valid for damage caused by drilling through the mounting holes 2 2 Installing transducer The log and depth transducers need to be positioned carefully The transducer must remain in the water at all speeds Turbulent water causing air bubbles must be avoided The best position fo...

Страница 7: ... transducer The connector is colour coded with green yellow white and ground sign Connect the four wires from the log transducer according to the colours to the connector for LOG the blank wire is ground If a depth transducer is connected use the DEPTH connector for that Power supply is either connected to green and ground for DEPTH or LOG Log transducer and power supply Log and depth transducers ...

Страница 8: ...n Log mode and Depth mode One short press changes between the two modes To select light levels press mode for more than two seconds 3 1 2 Down button This button is used to move down in the sub function list or to decrease a value in set mode 3 1 3 Up button This button is used to move up in the sub function list or to increase a value in set mode 3 1 4 KEY button This button is used to lock unloc...

Страница 9: ... is dis played To clear the trip distance press UP and DOWN together Range 0 199 99 Nm 3 2 4 Total distance To view the total distance press UP or DOWN Total distance is not possible to clear and will be stored in the instruments permanent memory Range 0 19999 99 Nm 3 2 5 Depth To view depth press UP or DOWN until the text DPT is displayed The depth function is only displayed if instrument type is...

Страница 10: ... To change the alarm value unlock with KEY increase decrease the value with UP DOWN move to the next figure with MODE button and lock the value again with KEY 3 4 3 Deep alarm To get to the deep alarm function press UP or DOWN until the text DEEP is displayed To change the alarm value unlock with KEY increase decrease the value with UP DOWN move to next figure with MODE button and lock the value a...

Страница 11: ... Instrument type Type LOG The Star SEA Data instrument can either be operating as a log instrument LOG a depth instrument DPT or as a combined log depth instrument ALL There is also a demonstration mode built into the instrument DEM If LOG is selected only log functions will be displayed If DPT is selected only depth functions will be displayed In demonstration mode DEM all values are simulated wi...

Страница 12: ... from either the keel or the water surface Example Your boat has a draft of two metres and the transducer is mounted one half metre below the water surface 1 If you want the reading from the water surface you have to add 0 5 m 2 If you want the reading from the keel you have to subtract 1 5 m Note Calibration should be carried out in the same unit chosen for dis play 4 2 8 C17 Unit for temperature...

Страница 13: ... function and press KEY and MODE together the display is flashing Go to the depth functions by pressing MODE and lock with KEY It is possible to move two functions one under speed and one under depth The last customised display is the display the instrument starts up in after power on If you want the instrument to start up displaying speed and trip after power on go to the trip function under spee...

Страница 14: ...Sea Data English 13 5 Warranty ...

Страница 15: ...English Sea Data 14 ...

Страница 16: ...Sea Data English 15 Copyright Silva Sweden AB Kuskvägen 4 191 62 Sollentuna Sweden Tel 46 0 8 623 43 00 Fax 46 0 8 92 76 01 www silva se 22172 3 Edition 2 ...

Отзывы: