background image

21

Manufacturer warrants, to the purchaser and 

subsequent owner during the warranty period, 

every new product to be free from defects in 

material and workmanship under normal use and 

service, when properly used and maintained, 

for a period of one year from date of purchase 

by the end user, or 18 months from date of 

original manufacture of the product, whichever 

comes first.  Parts that fail within the warranty 

period, one year from date of purchase by the 

end user, or 18 months from the date of original 

manufacture of the product, whichever comes 

first, that inspections determine to be defective 

in material or workmanship, will be repaired, 

replaced or remanufactured at Manufacturer’s 

option, provided however, that by so doing we will 

not be obligated to replace an entire assembly, 

the entire mechanism or the complete unit.  No 

allowance will be made for shipping charges, 

damages, labor or other charges that may occur 

due to product failure, repair or replacement.

This warranty does not apply to and there shall 

be no warranty for any material or product 

that has been disassembled without prior 

approval of Manufacturer, subjected to misuse, 

misapplication, neglect, alteration, accident or 

act of God; that has not been installed, operated 

or maintained in accordance with Manufacturer’s 

installation instructions; that has been exposed 

to outside substances including but not limited 

to the following:  sand, gravel, cement, mud, 

tar, hydrocarbons, hydrocarbon derivatives (oil, 

gasoline, solvents, etc.), or other abrasive or 

corrosive substances, wash towels or feminine 

sanitary products, etc. in all pumping applications.  

The warranty set out in the paragraph above is in 

lieu of all other warranties expressed or implied; 

and we do not authorize any representative or 

other person to assume for us any other liability 

in connection with our products.

Contact Manufacturer at, 95 North Oak Street, 

Kendallville, IN 46755, Attention: Customer 

Service Department to obtain any needed repair 

or replacement of part(s) or additional information 

pertaining to our warranty.

MANUFACTURER EXPRESSLY DISCLAIMS 

LIABILITY FOR SPECIAL, CONSEQUENTIAL 

OR INCIDENTAL DAMAGES OR BREACH 

OF EXPRESSED OR IMPLIED WARRANTY; 

AND ANY IMPLIED WARRANTY OF FITNESS 

FOR A PARTICULAR PURPOSE AND OF 

MERCHANTABILITY SHALL BE LIMITED 

TO THE DURATION OF THE EXPRESSED 

WARRANTY.

Some states do not allow limitations on the 

duration of an implied warranty, so the above 

limitation may not apply to you. Some states do 

not allow the exclusion or limitation of incidental 

or consequential damages, so the above 

limitation or exclusion may not apply to you.

This warranty gives you specific legal rights and 

you may also have other rights which vary from 

state to state.

WARRANTY

In those instances where damages are incurred as a result of an alleged pump failure, the 

Homeowner must retain possession of the pump for investigation purposes.

Содержание PowerFlush Optima S1201

Страница 1: ...ct For replacement pump order N202RP or see complete repair parts list on page 22 P N 018547 G Product information presented here reflects conditions at time of publication Consult factory regarding d...

Страница 2: ...not deliver sufficient voltage to the pump motor But more important they could present a safety hazard if the insulation were to become damaged or the connection end were to fall into a damp or wet a...

Страница 3: ...t use an automatic plumbing vent device Toilet will not flush PRODUCT DAMAGE MAY RESULT Maximum operating temperature for models S1201 S1202 must not exceed 104 F 40 C Duty cycle should not exceed 30...

Страница 4: ...ng 1 G Clamps for rubber coupling 2 H Toilet hardware pack 1 J Installation instructions 1 Not Shown PREPARATION Parts Required For Assembly not included Discharge pipe and fittings per code vent pipe...

Страница 5: ...tank system is designed to move waste water and sewage up to existing sewer lines recommended for installations up to 20 ft total dynamic head Recommended for up to 20 ft total dynamic head IL1733 2...

Страница 6: ...grinder tank unit is hidden behind wall For installation behind a wall extension kit 023260 sold separately is required 4 GENERAL PUMP USES IL1730 3 Exposed Installation grinder tank unit is visible...

Страница 7: ...existing discharge and vent lines Installation behind a wall will require extension kit 023260 sold separately 1 2 Level grinder tank unit to within 1 8 in for length and width Use hydraulic cement or...

Страница 8: ...ht side up and position the tank on the bowl by centering the gasket and aligning holes on the bowl Install tank to bowl bolts and rubber washers with narrow side down through the tank and bowl 3 Push...

Страница 9: ...8 Water supply line not included 9 Plastic flat washer 10 Plastic nut 11 Bolt cover 12 Toilet bowl TOILET ASSEMBLY WATER SUPPLY HOOKUP 1 Make sure the incoming water supply is turned off Water Supply...

Страница 10: ...allcock shank CAUTION Do not overtighten Ballcock shank may split and void the warranty WATER SUPPLY HOOKUP Ballcock Toilet Tank Rubber Washer Plastic Adapter IL1739 2 Place the toilet in front of gri...

Страница 11: ...Location Closet Screw Set Locations 3 4 Lightly mark the wall with the height of the grinder tank unit and the bottom and sides of the toilet tank to prevent interference from pipe runs during pipe i...

Страница 12: ...Grinder tank unit Toilet Tank Bottom and Sides IL1743 HIDDEN PUMP UNIT INSTALLATION 2 Position the grinder tank unit behind the wall Measure the appropriate length of 3 in Schedule 40 PVC pipe provid...

Страница 13: ...ing is required for the toilet to flush Do not use a mechanical type vent 3 A 2 in x 1 in 90 discharge fitting and a 1 1 2 in street elbow vent fitting have been provided for space constraints in an e...

Страница 14: ...e to discharge fitting ensure that none gets into the check valve assembly which is built into the cover of the grinder tank unit Pay close attention to the proper alignment of the discharge fitting p...

Страница 15: ...ling onto the toilet discharge and grinder tank unit hub and secure with the worm clamps provided 2 Place the toilet assembly over the closet screw sets Install the anchoring hardware and tighten in a...

Страница 16: ...er level Adjust if required TOILET INSTALLATION 4 For hidden installation using optional extension kit 023260 install the rubber couplings to both the grinder tank unit and the toilet discharge and se...

Страница 17: ...es to assure proper operation 7 Plug the pump s power cord into the GFCI outlet TOILET INSTALLATION RESET RE SE T TEST TE ST IL1756 Pump Plug GFCI Outlet Check for leaks Listen for pump to start IL175...

Страница 18: ...tside diameter or the 1 in slip inside diameter These side inlets are sealed by the factory to prevent leaks when inlets are not used Before use these side inlets must be drilled out using a 1 in hole...

Страница 19: ...ns must comply with all applicable Electrical and Plumbing Codes including but not limited to National Electrical Code Local Regional and or State Plumbing Codes etc 8 Ft Ceiling 7 Ft Ceiling Sub Floo...

Страница 20: ...Raise the lower float stop Pump is air locked Make sure vent hole in discharge pipe is clear Water level too low Raise the lower float stop Waste material has accumulated blocking flow of material Ho...

Страница 21: ...de substances including but not limited to the following sand gravel cement mud tar hydrocarbons hydrocarbon derivatives oil gasoline solvents etc or other abrasive or corrosive substances wash towels...

Страница 22: ...pipe N A WM202RPPC 3 Tank cover with discharge fittings 1 017373 017373 4 Tank 1 018500 018500 5 Seal 1 017350 017350 6 Float switch assembly Piggyback float style 1 018501 N A Float switch assembly F...