To Disinfect the Cushion:

 Periodic cleaning is all that is recommended unless there 

is a known infection or an open wound. If disinfection is desired, follow the above 
cleaning instructions using a solution of 1 part household liquid chlorine bleach to 9 
parts warm water. Soak the product for 10 minutes in the solution, rinse completely, 
and dry thoroughly. Do Not Use Undiluted Bleach!

Note: Most germicidal disinfectants are safe if used following the disinfectant manu-

facturer’s dilution directions.

 

DO NOT: 

 

machine wash or machine dry the cushion. 

 

use abrasives such as steel wool or scouring pads. 

 

use cleaning products containing petroleum or organic solvents. 

 

allow water or cleaning solution to enter the product (make sure  

 

 

the valve(s) are closed tightly before starting). 

 

expose the product to ultraviolet light or ozone gas cleaning    

  methods. 

 

use oil-based lotions, lanolin, or phenolic-based disinfectants on 

 

 

 

your product, as they may compromise the integrity of the mate 

  rial. 

To Sterilize the Cushion: 

Follow Cleaning and Disinfection guidelines above. Star 

Cushion’s products are not packaged in a sterile condition nor are they intended or 
required to be sterilized prior to usage. High temperatures can accelerate aging of the 
product and may cause damage or failure. If institution protocol demands steriliza

-

tion, open the valve(s) and use the lowest temperature possible for the shortest time 
possible. Neither are recommended, but gas sterilization is preferable to steam au

-

toclave. In any process using pressure, ensure all valves are open to prevent damage 
to the product. Star Cushion Products, Inc. highly discourages sterilization methods 
using temperatures greater than 180° F (82° C) for air-adjustable products. 

Deodorizing:

 To deodorize products mix one tablespoon of baking soda per quart of 

water (25 gm/l) in 10 parts water. Soak for several hours, rinse and let dry. This may 
need to be repeated several times. Clean product frequently or use an incontinent 
covering to avoid strong odors and staining.

Содержание CXR

Страница 1: ...Manual For High Standard Air Mid Standard Air Short Standard Air MAX Immerse and CXR Cushions Dynamic Air Flow Cushion Users Read instructions before using product and save this manual for future ref...

Страница 2: ...f Contents Page 2 Intended Use Page 3 4 Customer Responsibilities Cautions Page 5 Product Specifications Page 6 What is Included Page 7 8 Instructions for Use Page 9 Cover Use and Removal Page 10 11 C...

Страница 3: ...ssue protection and an environment to facilitate wound healing Short Standard Air 2 or 5 cm Single Valve Star Cushion Mid Standard Air 3 or 7 5 cm Single Valve Star Cushion High Standard Air 4 or 10 c...

Страница 4: ...his manual Instructions for Use If they are not the benefits provided by the cushion may be decreased or eliminated which increases risk to the skin and or soft tissue Further it may increase the risk...

Страница 5: ...on each time you change altitude Puncture In order to prevent your cushion from being punctured keep your cushion away from sharp objects Handling DO NOT attempt to carry your cushion by the valve s o...

Страница 6: ...ard Air single dual and four valve 4 10 cm 3 35lbs 1 52kg MAX Immerse single dual and four valve 5 12 7 cm 4 50lbs 2 04kg Coccyx Relief Cushion dual valve 4 10 cm 3 10lbs 1 41kg Note The average weigh...

Страница 7: ...r and will allow air to be distributed evenly across the whole cushion C Inflation Valve supports the flow of air into the cushion D Pump dual action pump to inflate the air cells through the inflatio...

Страница 8: ...n it by turning the silver tip counterclockwise Do not apply pressure when opening and closing valve The valve maintains a tight seal with little effort 3 Attach the rubber hose end of the black hand...

Страница 9: ...positioned in an appropriate and comfortable position 8 Now place your hand between the cushion and your boniest prominence usually your ischials 9 Open the valve and begin slowly letting air escape f...

Страница 10: ...valve cushion the valves will go into the cover first 3 Close the Velcro flap and turn the cushion over so cells are facing up 4 Make sure the valve s come out of the corner s of the cover for inflat...

Страница 11: ...and organic matter from the product Disinfecting is the elimination of pathogenic microorganisms Cleaning must precede disinfection To Clean the Cushion Close the cushion valve s Using a washcloth spo...

Страница 12: ...ants on your product as they may compromise the integrity of the mate rial To Sterilize the Cushion Follow Cleaning and Disinfection guidelines above Star Cushion s products are not packaged in a ster...

Страница 13: ...period Warranty service is available by returning the cushion and or cushion cover at your expense to Star Cushion Products Inc Attn Repairs 5 Commerce Drive Freeburg IL 62243 Some states do not allow...

Страница 14: ...If large holes or other leaks are found see Warranty Section Uncomfortable Unstable Make sure cushion is not over inflated see Instructions for Use Make sure the air cells and the cover s stretch top...

Страница 15: ...el 46 371 58 73 00 Fax 46 371 58 73 90 info etac se www etac se Etac AB export Box 203 334 24 Anderstorp Sverige Tel 46 371 58 73 30 Fax 46 371 58 73 90 info etac se www etac com Etac A S Egeskovvej 1...

Страница 16: ...Toll Free 888 277 7827 Fax 618 539 7073 Sales starcushion com www StarCushion com The Quality Management System of Star Cushion Products Inc is certified to ISO 9001 2008 and ISO 13485 2003 Etac Suppl...

Отзывы: