Star 515TGD-AP Скачать руководство пользователя страница 3

 

CAUTION

 This equipment is designed and sold for commercial use only by personnel trained and 

experienced in its operation and is not sold for consumer use in and around the home nor 

for use directly by the general public in food service locations.

 Before using your new equipment, read and understand all the instructions & labels 

associated with the unit prior to putting it into operation.  Make sure all people associated 

with its use understand the units operation & safety before they use the unit.

 All shipping containers should be checked for freight damage both visible and concealed.  

This unit has been tested and carefully packaged to insure delivery of your unit in perfect 

condition.  If equipment is received in damaged condition, either apparent or concealed, a 

claim must be made with the delivering carrier.

 Concealed damage or loss - if damage or loss is not apparent until after equipment is 

unpacked, a request for inspection of concealed damage must be made with carrier within 

5 days.  Be certain to retain all contents plus external and internal packaging materials for 

inspection.  The carrier will make an inspection and will supply necessary claim forms.

INSTALLATION

The griddles are equipped for the voltage indicated on the nameplate mounted under the 

bullnose on the front panel.  They will operate on alternating current (AC) only. 

 

WARNING

DO NOT CONNECT TO DIRECT CURRENT (DC).

The installation of the electric griddle should conform to the:

NATIONAL  ELECTRIC  CODE AND ALL  LOCAL  ELECTRIC  CODES AND 

ORDINANCES  AND  THE  LOCAL  ELECTRIC  COMPANY  RULES  AND 

REGULATIONS

For your protection we recommend that a qualified electrician install this griddle.  He should 

be familiar with electrical installations and all electric codes.  Proper connections and power 

supply are essential for efficient performance.  The supply circuit should be properly fused and 

equipped with a means of disconnecting, as required by local electrical code.  

THE BODY OF 

THE GRIDDLE SHOULD BE GROUNDED (DO NOT GROUND TO A GAS SUPPLY LINE).

GENERAL OPERATING PROCEDURES

The Star-Max series electric griddles may be wired for operation in the field for 1-phase power 

supplies by making line connections with the power cord located at the rear of the unit. Be 

certain the unit is supplied with the proper voltage listed on the nameplate.

ELECTRICAL CONNECTION

 Disconnect the unit from the power source before installing or removing any parts.

 WARNING

 DO NOT CUT OR REMOVE THE PLUG OR GROUNDING PRONG FROM THE PLUG.
 CONNECT/PLUG UNIT INTO DEDICATED A.C. LINE ONLY SPECIFIED ON THE 

DATA PLATE OF THE UNIT.

LOCATING AND LEVELING THE UNIT

Do not install the unit closer than one inch from a side wall and/or closer than one inch from a 

rear wall.  Level unit by adjusting the four (4) feet which have an adjustment of -/4” (4.75mm) 

for accurate leveling and perfect line-up with other Star-Max series units.

Содержание 515TGD-AP

Страница 1: ...ELECTRIC GRIDDLES MODEL 515TGD AP 524TGD AP Installation and Operation Instructions 2M Z10018 Rev E 12 29 08 524TGD AP 3 3 5 0 3 3...

Страница 2: ...onsible for errors or omissions in information provided or conclusions reached as a result of using the specifications By using the information provided the user assumes all risks in connection with s...

Страница 3: ...ent AC only WARNING DO NOT CONNECT TO DIRECT CURRENT DC The installation of the electric griddle should conform to the NATIONAL ELECTRIC CODE AND ALL LOCAL ELECTRIC CODES AND ORDINANCES AND THE LOCAL...

Страница 4: ...e thermostat will automatically maintain the selected temperature IDLING During idle periods to save on operating costs lower the temperature setting of the thermostat to about 250 F 121 C It is not n...

Страница 5: ...ha comes in continuous contact with the roller coating This warranty does not apply to the non stick properties of such materials This warranty does not apply to Special Products but to regular catalo...

Страница 6: ......

Страница 7: ......

Страница 8: ...33 31 Nameplate 4 34 6 3 2 32 11 24 25 29 12 13 14 15 16 17 18 20 19 20 STAR MANUFACTURING INTERNATIONAL INC MODEL 524TGD AP CERTAIN INSTANCES MAY NOT BE AVAILABLE ILLUSTRATIVE PURPOSES ONLY AND IN S...

Страница 9: ...4 2E Z9565 1 TERMINAL BLOCK 5 POS ALL 15 HI Z9843 1 CONNECTION BOX COVER ALL 16 2C 6349 2 SCREW 8X3 8 B THP STL NO ALL 17 2C Y4009 2 SCREW 8 32X1 5 STL RH NP ALL 18 G3 536300 1 WIRE ASSY GRN 5 8 RNG A...

Страница 10: ...10...

Страница 11: ...11...

Страница 12: ...12 STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 314 678 6314 www star mfg com...

Отзывы: