4
© Copyright 2018 Star Water Systems. All rights reserved.
1.1) Select a location for the pump that is below the evaporator drain and/or furnace drain.
1.2) The unit has two brackets built into the deck so that it can be installed to the wall or side of the appliance.
Refer to Figure 1.2.
2.1) To prevent pipe blockage, modify the end of the pipe or tubing as shown in Figure 2.1.
2.2) Plumb, flexible tube or pipe, from the condensate drain and/or from the furnace drain to the inlet hole(s) on
the pump. Refer to Figure 2.2.
Figure 1.2
Figure 2.2
Figure 2.1
Note:
The drain line(s) should have a continuous downward slope to allow for gravity flow.
Note:
Local codes may require the use of a condensate neutralizer when using this pump.
Note:
Make sure the drain lines from the A.C. condenser are supported above the reservoir and no weight from the
drain line is directed to the bottom of the reservoir.
SK1762
STEP 1
Mounting Location
STEP 2
Installation of Condensate Drain Lines
SK1762
CONDENSING GAS
FURNACE
OVERFLOW
MAIN CONDENSATE DISCHARGE
CONDENSATE TRAP
GFCI
OUTLET
MOUNTING BRACKETS
SK1765
Drain Pipe
45°
SK1763
CONDENSING GAS
FURNACE
A/C CONDENSER
MAIN DRAIN FROM COIL
OVERFLOW DRAIN FROM
COIL WHEN REQUIRED
GFCI
OUTLET
MAIN DRAIN FROM FURNACE
CONDENSATE NEUTRILIZER
CARTRIDGE (IF REQUIRED)
OVERFLOW DRAIN
FROM FURNACE
Note:Insert, tubing
or pipe, through
the inlet until the
tip contacts bottom
of reservoir.