Star Progetti ATEX EHSAFE15 Скачать руководство пользователя страница 2

HELIOS ELECTRIC INFRARED IRK

SAFE INDUSTRY MODEL

1500 Watt (cod. EH SAFE 15) / 2000 Watt (cod. EH SAFE 20)

DIRECTIONS

PLEASE NOTE: safe use of this equipment can only be ensured if the user complies with these directions. Users must 
therefore keep these directions at hand at all times.
Helios Safe Industry is an extremely versatile infrared heater designed and constructed according to good practice 
and assembled with the best components conforming to standards and/or certificates for ensuring safety during use.

TECHNICAL DATA

* ALL  SPECIFICATIONS  INCLUDED  ARE  BASED  ON  TESTS.  OTHER  RESULTS  DEPEND  UPON  ENVIRONMENTAL
CONDITIONS DURING USE

Mark EHSAFE15 

 nA IIC T2 Gc

Mark EHSAFE20

nA IIC T2 Gc

ct III B T230° Dc IP66

ct III B T290° Dc IP66

-5°C £Ta£+25°C

-5°C £Ta£+25°C

CONSTRUCTION

* Steel body, oven epoxy powder coating
* Extra-pure, buffed, anodically oxidized aluminium parabolic reflector
* Front (ceramic, glass)
* Silicone rubber seal
* Supply cable: length 1.5 m and; resistant to Temperature = 180° C
* Adjustable wall anchorage

WARNING
PLEASE NOTE: THIS HEATER IS SUITABLE FOR INSTALLATION IN EXPLOSIVE ATMOSPHERE CONDITIONS, CLASSIFIED 
ZONE 2-22, PURSUANT TO DIRECTIVES 94/9 AND 99/92 EC ATEX

ZONE  2-22  indicates  that  the  atmosphere,  which  is  normally  not  explosive  during  routine  use,  may,  on  rare 
occasions,  briefly become  explosive  (generally  in  the  presence  of a  malfunction).  The  heater  therefore  cannot  be 
installed in zones other than those classed as ZONE 2-22. 

T2 

indicates that the ignition temperature of the flammable 

gasses of the classified zone must be higher than 300°C. The table below (from EN 13463-1) lists other temperature 
classes.
Temperature Class

Maximum Surface Temperature (°C)

T1

450

T2

300

T3

200

T4

135

T5

100

T6

85

       Read the various indications on the name plate. Conditions of use must correspond to the data indicated 

on the name plate.

ENGLISH

7

Содержание ATEX EHSAFE15

Страница 1: ...OPERATING INSTRUCTIONS HELIOS SAFE INDUSTRY ATEX 1500 Watt COD EHSAFE15 2000 Watt COD EHSAFE20 ...

Страница 2: ...uffed anodically oxidized aluminium parabolic reflector Front ceramic glass Silicone rubber seal Supply cable length 1 5 m and resistant to Temperature 180 C Adjustable wall anchorage WARNING PLEASE NOTE THIS HEATER IS SUITABLE FOR INSTALLATION IN EXPLOSIVE ATMOSPHERE CONDITIONS CLASSIFIED ZONE 2 22 PURSUANT TO DIRECTIVES 94 9 AND 99 92 EC ATEX ZONE 2 22 indicates that the atmosphere which is norm...

Страница 3: ...work The symbols included below indicate safety measures and supplementary instructions in these operational directions SPECIAL SAFETY INSTRUCTIONS AND GUARANTEE PLEASE NOTE To prevent damage to objects and personal injury users must proceed strictly in accordance with the safety measures and supplementary instructions contained in these operational directions PLEASE NOTE DO NOT SET THIS HEATER AT...

Страница 4: ...must be perfectly horizontal The appliance can also be installed on the ceiling with chains not supplied POSITIONING Point the Helios Safe Industry reflector beam as required during wall installation Normally the appliance is tilted at approx 45 with respect to the horizontal line Never install Helios SafeIndustry on a flammable surface or direct it toward a a flammable surface The appliance must ...

Страница 5: ... DIAGRAM 10 ...

Страница 6: ...WALL INSTALLATION PLEASE NOTE THE APPLIANCE MUST ALWAYS BE INSTALLED HORIZONTALLY AS ILLUSTRATED IN THE DRAWING ANCHORAGE REAR JOINT DETAIL CEILING INSTALLATION 11 ...

Страница 7: ...www heatxl com atex infrarood verwarming html ...